1SDX253469R1 ABB EPX-XT2N-TM0633 63A 3-Pole 36kA TMA MCCB Tmax XT2N Protecta Power

1SDX253469R1 ABB EPX-XT2N-TM0633 63A 3-Pole 36kA TMA MCCB Tmax XT2N Protecta Power

ABB EPX-XT2N-TM0633 is a 63 A three-pole Tmax XT2N160 moulded case circuit breaker with a 36 kA breaking-capacity classification and TMA thermal-magnetic overload and short-circuit protection for compatible ABB Protecta Power distribution assemblies.

SKU: 1SDX253469R1Alt SKU: EPX-XT2N-TM0633MPN: 1SDX253469R1
Price
List Price £444.10 ex VAT
Your Price (ex VAT)
£444.10
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £444.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£444.10

ABB EPX-XT2N-TM0633 63A 3-Pole 36kA TMA MCCB – Tmax XT2N Protecta Power

The ABB EPX-XT2N-TM0633 is a 63 A, three-pole moulded case circuit breaker (MCCB) designed for reliable overload and short-circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies. Based on the ABB SACE Tmax XT2N160 circuit breaker platform, this device combines a 36 kA breaking-capacity classification with an adjustable TMA thermal-magnetic trip unit for commercial and industrial electrical installations.

Designed for professional three-phase power distribution, the EPX-XT2N-TM0633 provides protection for appropriately rated outgoing circuits, sub-distribution feeders and connected electrical equipment. Its 63 A rated current and compact three-pole construction make it a practical choice for distribution panelboards where reliable protection and efficient use of installation space are important.

The TMA thermal-magnetic release combines thermal overload protection with adjustable instantaneous magnetic short-circuit protection. The corresponding ABB XT2N 160 TMA 63-630 breaker provides a 63 A thermal reference rating and a 315–630 A magnetic adjustment range. These characteristics allow the circuit breaker to respond to sustained overloads and high fault currents while supporting appropriate coordination with the electrical installation.

The ABB Tmax XT2N platform provides a compact moulded case construction with mechanical switching and fault-interruption capability. The corresponding XT2N 160 TMA configuration uses a fixed installation arrangement with front terminals, making it suitable for integration into appropriately designed low-voltage distribution equipment.

Identified by ABB order code 1SDX253469R1, the EPX-XT2N-TM0633 belongs to the ABB Protecta Power Devices range. It offers electrical contractors, consultants and panel builders a manufacturer-specified 63 A outgoing MCCB option for compatible Protecta Power assemblies requiring three-pole thermal-magnetic protection and a 36 kA breaking-capacity classification.

Key Advantages

  • 63 A rated current: Provides overload and short-circuit protection for appropriately designed three-phase distribution circuits.
  • 36 kA breaking-capacity classification: Supports protection in installations with substantial prospective short-circuit currents, subject to the applicable operating voltage.
  • Three-pole construction: Provides coordinated switching and protection of three phase conductors.
  • ABB Tmax XT2N technology: Uses ABB's established SACE Tmax XT moulded case circuit breaker platform.
  • TMA thermal-magnetic protection: Combines thermal overload protection with magnetic short-circuit protection.
  • Adjustable magnetic threshold: Provides a 315–630 A instantaneous magnetic setting range on the corresponding XT2N 63 A breaker.
  • Compact 160 A frame: Supports efficient installation within compatible electrical distribution assemblies.
  • Fixed mounting configuration: The corresponding ABB XT2N breaker uses a fixed construction with front terminals.
  • Protecta Power compatibility: Designed for appropriate ABB Protecta Power outgoing MCCB arrangements.
  • Professional circuit protection: Supports electrical contractors and panel builders specifying dependable low-voltage distribution equipment.

Key Features

  • ABB EPX-XT2N-TM0633 outgoing moulded case circuit breaker.
  • 63 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA Protecta Power breaking-capacity classification.
  • ABB SACE Tmax XT2N160 circuit breaker family.
  • 160 A frame-current designation.
  • TMA thermal-magnetic trip unit.
  • Thermal overload protection for sustained overcurrent conditions.
  • Magnetic short-circuit protection for high fault currents.
  • 315–630 A instantaneous magnetic adjustment range on the corresponding XT2N TMA breaker.
  • Manual circuit breaker switching and resetting.
  • Fixed construction in the corresponding ABB XT2N configuration.
  • Front terminal arrangement in the corresponding ABB breaker configuration.
  • 100 mm nominal three-pole XT2 device width.
  • Designed for compatible ABB Protecta Power outgoing circuits.
  • Suitable for commercial and industrial low-voltage electrical distribution.

Reliable 63A Three-Phase Protection with ABB Tmax XT2N Technology

The ABB EPX-XT2N-TM0633 provides dependable protection for suitably rated electrical distribution circuits against overload and short-circuit conditions. Combining the ABB Tmax XT2N platform with thermal-magnetic protection, it offers a practical solution for professional low-voltage distribution installations.

The thermal overload protection function responds to sustained overcurrent conditions that could otherwise cause excessive heating of electrical cables and connected equipment. The corresponding XT2N TMA breaker has a 63 A thermal reference rating, supporting protection of appropriately sized conductors and connected loads.

The magnetic short-circuit protection function responds to high fault currents. On the corresponding ABB XT2N 160 TMA 63-630 breaker, the instantaneous magnetic setting can be adjusted within a range of 315–630 A. This allows the protection threshold to be selected according to the circuit's operating characteristics and fault protection requirements.

The TMA thermal-magnetic release uses thermal and magnetic operating elements rather than an electronic trip unit. This provides conventional overcurrent protection without requiring electronic configuration or external electronic monitoring equipment.

The three-pole construction enables coordinated switching and protection of the three phase conductors in suitable electrical distribution systems. It is appropriate for installations where the circuit design does not require a fourth switching pole for the neutral conductor.

The 36 kA breaking-capacity classification is an important consideration when specifying protection for installations with substantial prospective short-circuit currents. The applicable ultimate and service breaking capacities must be verified at the installation's operating voltage, as circuit breaker interruption ratings can vary with voltage.

The ABB XT2N160 frame provides a compact mechanical platform for the 63 A protective device. ABB's Protecta Power selection information identifies a nominal 100 mm width for three-pole XT2 outgoing devices, helping panel builders plan efficient device layouts.

The corresponding ABB XT2N 160 TMA breaker uses a fixed mounting configuration with front terminals. These characteristics support integration into properly designed electrical distribution assemblies, provided the correct connection components, protective covers and installation clearances are used.

When installing the EPX-XT2N-TM0633 within an ABB Protecta Power panelboard, the appropriate mounting arrangement and outgoing connections must be selected. Compatibility should be checked using the relevant ABB Protecta Power installation and selection documentation.

Before commissioning, electrical contractors should verify conductor current-carrying capacity, termination suitability, prospective short-circuit current, protective coordination and the magnetic trip setting. The selected protection characteristics must be appropriate for the connected equipment and installation conditions.

With its 63 A current rating, three-pole construction, 36 kA breaking-capacity classification and ABB TMA protection technology, the EPX-XT2N-TM0633 provides a practical outgoing MCCB solution for commercial and industrial electrical distribution applications.

Typical Applications

  • ABB Protecta Power outgoing circuit protection.
  • 63 A three-phase electrical distribution circuits.
  • Commercial low-voltage distribution panelboards.
  • Industrial electrical switchgear assemblies.
  • Manufacturing plants and production facilities.
  • Warehouses and logistics distribution centres.
  • Office buildings and retail premises.
  • Building services electrical distribution.
  • Suitable machinery and fixed equipment supply circuits.
  • Three-phase sub-distribution feeders.
  • Electrical distribution board refurbishment.
  • Professional electrical panel building projects.
  • Installations requiring thermal-magnetic overload and short-circuit protection.

Technical Specifications

Product group Protecta Power Devices
Product model EPX-XT2N-TM0633
ABB order code 1SDX253469R1
Product type Moulded case circuit breaker (MCCB)
Circuit breaker range ABB SACE Tmax XT
Circuit breaker family XT2N
Frame designation XT2N160
Frame-current designation 160 A
Rated current (In) 63 A
Number of poles 3
Pole configuration Three-pole (3P)
Breaking-capacity classification 36 kA
Trip unit TMA
Protection technology Thermal-magnetic
Thermal protection reference 63 A
Instantaneous magnetic adjustment range 315–630 A for the corresponding XT2N 160 TMA 63-630 breaker
Overload protection Thermal
Short-circuit protection Magnetic
Rated voltage of corresponding XT2N breaker 690 V AC
Operating mechanism Manual
Corresponding breaker installation configuration Fixed
Corresponding breaker terminal arrangement Front terminals
Nominal three-pole XT2 device width 100 mm
Applicable circuit breaker standard IEC 60947-2
ABB product designation XT2N 160 TMA 63-630 3p F F + Acc
Compatible distribution system ABB Protecta Power
Related 50 A three-pole model EPX-XT2N-TM0503
Related 80 A three-pole model EPX-XT2N-TM0803
Related 100 A three-pole model EPX-XT2N-TM1003
Related 63 A four-pole model EPX-XT2N-TM0634
Related 63 A XT2S three-pole model EPX-XT2S-TM0633
Primary application Three-phase outgoing circuit protection in compatible low-voltage distribution assemblies

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0633 used for?

The ABB EPX-XT2N-TM0633 is a 63 A three-pole thermal-magnetic MCCB designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies.

What is the rated current of the EPX-XT2N-TM0633?

The EPX-XT2N-TM0633 has a rated current of 63 A and belongs to the ABB Tmax XT2N160 circuit breaker family, which uses a 160 A frame designation.

What is the breaking capacity of the EPX-XT2N-TM0633?

The EPX-XT2N-TM0633 has a 36 kA breaking-capacity classification in the ABB Protecta Power range. The applicable breaking capacity must be verified at the installation's operating voltage.

Is the EPX-XT2N-TM0633 a three-pole circuit breaker?

Yes. The EPX-XT2N-TM0633 is a three-pole (3P) MCCB designed to protect and switch three phase conductors in suitable low-voltage electrical distribution systems.

What does TMA mean on the ABB EPX-XT2N-TM0633?

TMA identifies a thermal-magnetic trip unit that provides thermal overload protection and magnetic short-circuit protection. The corresponding ABB XT2N 63 A TMA breaker includes an adjustable instantaneous magnetic setting.

What is the magnetic adjustment range of the XT2N 63A TMA breaker?

The corresponding ABB XT2N 160 TMA 63-630 breaker provides an instantaneous magnetic adjustment range of 315–630 A. The selected setting must be appropriate for the circuit's fault conditions and protection coordination requirements.

What is the difference between EPX-XT2N-TM0633 and EPX-XT2N-TM0503?

The EPX-XT2N-TM0633 has a rated current of 63 A, while the EPX-XT2N-TM0503 has a rated current of 50 A. Both are three-pole ABB Tmax XT2N thermal-magnetic MCCB configurations with a 36 kA breaking-capacity classification.

What is the difference between EPX-XT2N-TM0633 and EPX-XT2N-TM0634?

The EPX-XT2N-TM0633 is a 63 A three-pole MCCB, while the EPX-XT2N-TM0634 is the corresponding 63 A four-pole version. The correct pole configuration depends on the electrical distribution system and installation requirements.

Can the EPX-XT2N-TM0633 be installed in ABB Protecta Power panelboards?

Yes. The EPX-XT2N-TM0633 belongs to the ABB Protecta Power Devices range and is intended for compatible low-voltage distribution assemblies. The correct mounting components, electrical connections and protective covers must be confirmed before installation.

Trusted by Electrical Contractors and Panel Builders

ABB Protecta Power moulded case circuit breakers provide a coordinated approach to low-voltage electrical distribution. The EPX-XT2N-TM0633 combines a 63 A rating, three-pole Tmax XT2N construction, 36 kA breaking-capacity classification and TMA thermal-magnetic protection, supporting electrical contractors and panel builders in creating dependable, professionally assembled distribution systems.