1SDX253467R1 ABB EPX-XT2N-TM0403 40A 3P 36kA MCCB - TMA

1SDX253467R1 ABB EPX-XT2N-TM0403 40A 3P 36kA MCCB – TMA

ABB EPX-XT2N-TM0403 is a 40 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and TMA thermal-magnetic protection, designed for reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253467R1Alt SKU: EPX-XT2N-TM0403MPN: 1SDX253467R1
Price
List Price £444.10 ex VAT
Your Price (ex VAT)
£444.10
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £444.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£444.10

Why Choose the ABB EPX-XT2N-TM0403 40A 3-Pole MCCB?

The ABB EPX-XT2N-TM0403 is a compact and reliable 40 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA short-circuit breaking capacity and a TMA thermal-magnetic trip unit, this circuit breaker belongs to the ABB Protecta Power Devices range and uses ABB's established Tmax XT2N circuit breaker technology.

Designed for commercial and industrial electrical installations, the EPX-XT2N-TM0403 combines effective circuit protection with a compact construction suitable for modern power distribution equipment. Its thermal-magnetic protection system provides overload protection and magnetic short-circuit tripping, helping safeguard electrical cables, connected equipment and distribution infrastructure against excessive current and electrical faults.

With a 40 A rated current, three-pole configuration and 36 kA breaking capacity, the ABB EPX-XT2N-TM0403 is particularly suitable for three-phase outgoing circuits in commercial distribution boards, industrial electrical panels and compatible ABB Protecta Power assemblies. Supplied under ABB order code 1SDX253467R1, this MCCB offers a dependable solution for protecting low-voltage electrical distribution circuits.

Key Advantages

  • Reliable 40 A moulded case circuit breaker designed for commercial and industrial electrical distribution.
  • Three-pole (3P) configuration provides simultaneous protection and switching of three-phase circuits.
  • 36 kA short-circuit breaking capacity for installations requiring high fault-current interruption capability.
  • TMA thermal-magnetic trip unit combines overload and short-circuit protection.
  • Adjustable thermal protection enables appropriate overload settings within the supported trip-unit range.
  • Magnetic short-circuit protection provides rapid interruption during high-current faults.
  • Compact ABB Tmax XT2N frame helps optimise space inside electrical distribution assemblies.
  • Designed for integration into compatible ABB Protecta Power distribution systems.
  • Robust mechanical construction supports dependable operation and straightforward circuit switching.
  • Suitable for new electrical installations and compatible circuit breaker replacement applications.

Key Features

  • ABB Protecta Power Devices product group.
  • ABB Tmax XT2N moulded case circuit breaker platform.
  • 40 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA short-circuit breaking capacity at the applicable rated voltage.
  • TMA thermal-magnetic trip unit for overload and short-circuit protection.
  • Adjustable thermal trip setting for circuit protection requirements.
  • Magnetic trip mechanism for rapid fault-current interruption.
  • XT2N 160 A frame family with a 40 A trip-unit rating.
  • Manual toggle-operated switching mechanism.
  • Three-phase circuit isolation when installed and applied in accordance with the manufacturer's requirements.
  • Compact moulded case construction suitable for distribution equipment.
  • Designed for low-voltage commercial and industrial electrical installations.
  • ABB manufacturer order code: 1SDX253467R1.

Reliable Circuit Protection for Commercial and Industrial Distribution

Moulded case circuit breakers such as the ABB EPX-XT2N-TM0403 protect electrical installations by automatically interrupting current when overload or short-circuit conditions occur. By combining circuit switching with protective tripping mechanisms, MCCBs help reduce the risk of damage to electrical cables, distribution equipment and connected installations.

The TMA thermal-magnetic trip unit uses two complementary protection principles. Its thermal element responds to sustained overload currents, while the magnetic element provides rapid tripping during high-current short circuits. The adjustable thermal protection allows the breaker to be configured for suitable circuit protection requirements, subject to the installation design and manufacturer's settings.

The ABB Tmax XT2N platform provides a compact and robust circuit breaker design for modern low-voltage switchgear. The EPX-XT2N-TM0403 uses a 40 A protective rating within the XT2N frame family, offering three-pole protection for appropriately rated outgoing distribution circuits.

As part of the ABB Protecta Power Devices range, this MCCB is intended for use with compatible electrical distribution equipment. Its 36 kA breaking capacity makes it suitable for installations where the prospective short-circuit current does not exceed the breaker's verified interruption capability at the relevant operating voltage.

Typical Applications

  • ABB Protecta Power distribution boards and compatible electrical assemblies.
  • Commercial low-voltage power distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuit protection.
  • Commercial building electrical sub-distribution boards.
  • Manufacturing facilities and industrial infrastructure.
  • Building services and mechanical plant electrical distribution.
  • Distribution circuits supplying appropriately rated machinery and equipment.
  • Electrical installations requiring adjustable thermal overload protection.
  • Electrical refurbishment and replacement of compatible ABB circuit breakers.

Technical Specifications

Product group Protecta Power Devices
Series Tmax XT2 / Protecta Power
ABB order code 1SDX253467R1
Product type Moulded case circuit breaker (MCCB)
Rated current 40 A
Number of poles 3
Pole configuration 3P
Short-circuit breaking capacity 36 kA
Breaking capacity classification N (normal breaking capacity)
Trip unit type TMA thermal-magnetic
Thermal trip setting range 28–40 A
Overload protection Adjustable thermal trip
Short-circuit protection Magnetic trip
Frame family XT2N
Frame rating 160 A
Rated operational voltage (frame family) Up to 690 V AC
Rated insulation voltage (frame family) 1,000 V
Rated impulse withstand voltage (frame family) 8 kV
Applicable standard IEC/EN 60947-2
Application Low-voltage electrical distribution
Installation type Compatible electrical distribution board / switchgear assembly
Operating mechanism Manual toggle-operated circuit breaker
Typical electrical system Three-phase AC distribution

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0403 used for?

The ABB EPX-XT2N-TM0403 is a three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT2N-TM0403?

The EPX-XT2N-TM0403 has a 40 A rated current. Its thermal-magnetic protection system is designed to provide overcurrent protection for appropriately rated electrical distribution circuits.

What is the breaking capacity of this MCCB?

The ABB EPX-XT2N-TM0403 has a specified 36 kA short-circuit breaking capacity. This represents its fault-interruption capability under the applicable rated conditions. The installation voltage and prospective fault current must be checked to confirm suitability.

What does TMA thermal-magnetic protection mean?

TMA thermal-magnetic protection combines a thermal overload protection element with a magnetic short-circuit protection element. The thermal mechanism responds to sustained excessive current, while the magnetic mechanism trips rapidly when a sufficiently high short-circuit current occurs.

Can the thermal protection setting be adjusted?

Yes. The corresponding ABB XT2N 40 A TMA trip unit provides an adjustable thermal protection setting, typically within a 28–40 A range. The appropriate setting must be selected according to the protected circuit and the manufacturer's installation requirements.

Is the ABB EPX-XT2N-TM0403 suitable for three-phase systems?

Yes. The three-pole (3P) configuration allows the circuit breaker to switch and protect three phase conductors together, making it suitable for appropriately designed three-phase low-voltage distribution circuits.

What is the ABB order code for the EPX-XT2N-TM0403?

The ABB manufacturer order code is 1SDX253467R1. The corresponding product reference is EPX-XT2N-TM0403, identifying the 40 A, three-pole, 36 kA thermal-magnetic MCCB within the ABB Protecta Power Devices range.

Where is the ABB EPX-XT2N-TM0403 typically installed?

This MCCB is typically installed within compatible electrical distribution boards, switchgear assemblies and commercial or industrial distribution panels. It is particularly suitable for ABB Protecta Power installations requiring 40 A three-pole outgoing circuit protection.

Trusted ABB Circuit Protection for Professional Installations

ABB Protecta Power circuit protection devices combine established Tmax XT circuit breaker technology with practical integration into modern electrical distribution systems. The EPX-XT2N-TM0403 provides dependable 40 A three-pole thermal-magnetic protection and a 36 kA breaking capacity for appropriately specified commercial and industrial installations.