1SDX253466R1 ABB EPX-XT2N-TM0323 32A 3P 36kA MCCB - TMA

1SDX253466R1 ABB EPX-XT2N-TM0323 32A 3P 36kA MCCB – TMA

ABB EPX-XT2N-TM0323 is a 32 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and TMA thermal-magnetic protection, designed for reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems.

SKU: 1SDX253466R1Alt SKU: EPX-XT2N-TM0323MPN: 1SDX253466R1
Price
List Price £444.10 ex VAT
Your Price (ex VAT)
£444.10
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £444.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£444.10

Why Choose the ABB EPX-XT2N-TM0323 32A 3-Pole MCCB?

The ABB EPX-XT2N-TM0323 is a compact and reliable 32 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA breaking capacity and thermal-magnetic protection, this circuit breaker forms part of the ABB Protecta Power Devices range and is based on ABB's proven Tmax XT2 circuit breaker platform.

Designed for commercial and industrial electrical installations, the EPX-XT2N-TM0323 combines robust circuit protection with a compact construction suitable for modern power distribution equipment. Its TMA thermal-magnetic trip unit provides protection against sustained overloads and high short-circuit currents, helping safeguard electrical cables, connected equipment and distribution infrastructure.

With a 32 A rated current, three-pole configuration and 36 kA short-circuit breaking capacity, the ABB EPX-XT2N-TM0323 is particularly suited to three-phase outgoing circuits in commercial distribution boards, industrial control panels and ABB Protecta Power distribution assemblies. Supplied under ABB order code 1SDX253466R1, this MCCB provides a practical solution for reliable low-voltage circuit protection.

Key Advantages

  • Reliable 32 A moulded case circuit breaker for low-voltage electrical distribution.
  • Three-pole protection suitable for three-phase electrical circuits.
  • 36 kA short-circuit breaking capacity for installations requiring high fault-current protection.
  • TMA thermal-magnetic trip unit provides overload and instantaneous short-circuit protection.
  • Compact ABB Tmax XT2 frame helps optimise space within electrical distribution assemblies.
  • Designed for integration with ABB Protecta Power distribution systems.
  • Mechanical switching and isolation functionality supports electrical maintenance and circuit management.
  • Robust construction designed for dependable operation in commercial and industrial environments.

Key Features

  • ABB Protecta Power Devices product range.
  • Tmax XT2N moulded case circuit breaker platform.
  • 32 A rated current.
  • Three-pole (3P) configuration.
  • 36 kA rated short-circuit breaking capacity.
  • TMA thermal-magnetic protection for overload and short-circuit conditions.
  • Thermal protection responds to sustained overcurrent conditions.
  • Magnetic protection provides rapid tripping during high short-circuit currents.
  • Compact moulded case construction for electrical distribution equipment.
  • Manual circuit switching with trip indication through the operating mechanism.
  • Suitable for three-phase low-voltage power distribution applications.
  • ABB manufacturer order code: 1SDX253466R1.

Reliable Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT2N-TM0323 protect electrical installations by automatically interrupting current when an overload or short-circuit fault occurs. Unlike conventional switching devices, MCCBs combine normal circuit switching with protective tripping mechanisms designed to limit damage to cables, electrical equipment and distribution infrastructure.

The TMA thermal-magnetic trip unit combines two complementary protection principles. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation during high-current short circuits. This combination makes the EPX-XT2N-TM0323 suitable for protecting outgoing distribution circuits where reliable overcurrent protection is essential.

As part of the ABB Protecta Power range, the EPX-XT2N-TM0323 is intended for integration into compatible low-voltage distribution assemblies. Its XT2 frame design offers a compact footprint, while the three-pole arrangement enables simultaneous switching and protection of all three phases. The specified 36 kA breaking capacity makes it suitable for appropriately designed installations where the prospective short-circuit current falls within the breaker's verified operating capability.

Typical Applications

  • ABB Protecta Power distribution boards and compatible assemblies.
  • Commercial low-voltage electrical distribution systems.
  • Industrial electrical distribution panels and switchgear.
  • Three-phase outgoing circuit protection.
  • Electrical sub-distribution boards in commercial buildings.
  • Manufacturing facilities and industrial infrastructure.
  • Building services and mechanical plant distribution.
  • Power distribution for appropriately rated machinery and equipment.
  • Electrical installations requiring thermal-magnetic overload and short-circuit protection.
  • Maintenance, refurbishment and replacement of compatible MCCBs in existing distribution assemblies.

Technical Specifications

Product group Protecta Power Devices
Series Tmax XT2 / Protecta Power
ABB order code 1SDX253466R1
Product type Moulded case circuit breaker (MCCB)
Rated current 32 A
Number of poles 3
Pole configuration 3P
Short-circuit breaking capacity 36 kA
Breaking capacity classification N (normal breaking capacity)
Trip unit type TMA thermal-magnetic
Overload protection Thermal trip mechanism
Short-circuit protection Magnetic trip mechanism
Frame family XT2
Frame rating 160 A
Application Low-voltage electrical distribution
Installation type Electrical distribution board / switchgear assembly
Operating mechanism Manual toggle-operated circuit breaker
Applicable circuit breaker standard IEC/EN 60947-2
Typical system Three-phase AC electrical distribution

Frequently Asked Questions

What is the ABB EPX-XT2N-TM0323 used for?

The ABB EPX-XT2N-TM0323 is a three-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.

What is the rated current of the ABB EPX-XT2N-TM0323?

The EPX-XT2N-TM0323 has a 32 A rated current and is designed to protect appropriately rated electrical circuits against excessive current.

What is the breaking capacity of this MCCB?

The ABB EPX-XT2N-TM0323 has a specified 36 kA short-circuit breaking capacity. This indicates its fault-interruption capability under the applicable rated test conditions. Suitability must be checked against the installation voltage and prospective fault current.

What does TMA thermal-magnetic protection mean?

TMA thermal-magnetic protection combines a thermal overload protection element with a magnetic short-circuit protection element. The thermal mechanism responds to sustained excessive current, while the magnetic mechanism trips rapidly when a sufficiently high fault current occurs.

Is the ABB EPX-XT2N-TM0323 suitable for three-phase systems?

Yes. The three-pole (3P) configuration allows the breaker to protect and switch three phase conductors together, making it suitable for appropriately designed three-phase low-voltage distribution circuits.

What is the ABB order code for the EPX-XT2N-TM0323?

The ABB manufacturer order code is 1SDX253466R1. The corresponding product reference is EPX-XT2N-TM0323, identifying the 32 A, three-pole, 36 kA thermal-magnetic MCCB within the Protecta Power Devices range.

Where is the ABB EPX-XT2N-TM0323 typically installed?

This MCCB is typically installed within compatible electrical distribution boards, switchgear assemblies and commercial or industrial distribution panels. It is particularly relevant to ABB Protecta Power installations requiring three-pole outgoing circuit protection.

Trusted ABB Circuit Protection for Professional Installations

ABB Protecta Power circuit protection devices combine established Tmax XT circuit breaker technology with practical integration into modern electrical distribution systems. The EPX-XT2N-TM0323 offers dependable 32 A three-pole thermal-magnetic protection and a 36 kA breaking capacity for appropriately specified commercial and industrial installations.