Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT2N-TM0323 is a 32 A three-pole moulded case circuit breaker with 36 kA short-circuit breaking capacity and TMA thermal-magnetic protection, designed for reliable overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems.
£444.10
The ABB EPX-XT2N-TM0323 is a compact and reliable 32 A three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Featuring a 36 kA breaking capacity and thermal-magnetic protection, this circuit breaker forms part of the ABB Protecta Power Devices range and is based on ABB's proven Tmax XT2 circuit breaker platform.
Designed for commercial and industrial electrical installations, the EPX-XT2N-TM0323 combines robust circuit protection with a compact construction suitable for modern power distribution equipment. Its TMA thermal-magnetic trip unit provides protection against sustained overloads and high short-circuit currents, helping safeguard electrical cables, connected equipment and distribution infrastructure.
With a 32 A rated current, three-pole configuration and 36 kA short-circuit breaking capacity, the ABB EPX-XT2N-TM0323 is particularly suited to three-phase outgoing circuits in commercial distribution boards, industrial control panels and ABB Protecta Power distribution assemblies. Supplied under ABB order code 1SDX253466R1, this MCCB provides a practical solution for reliable low-voltage circuit protection.
Moulded case circuit breakers such as the ABB EPX-XT2N-TM0323 protect electrical installations by automatically interrupting current when an overload or short-circuit fault occurs. Unlike conventional switching devices, MCCBs combine normal circuit switching with protective tripping mechanisms designed to limit damage to cables, electrical equipment and distribution infrastructure.
The TMA thermal-magnetic trip unit combines two complementary protection principles. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation during high-current short circuits. This combination makes the EPX-XT2N-TM0323 suitable for protecting outgoing distribution circuits where reliable overcurrent protection is essential.
As part of the ABB Protecta Power range, the EPX-XT2N-TM0323 is intended for integration into compatible low-voltage distribution assemblies. Its XT2 frame design offers a compact footprint, while the three-pole arrangement enables simultaneous switching and protection of all three phases. The specified 36 kA breaking capacity makes it suitable for appropriately designed installations where the prospective short-circuit current falls within the breaker's verified operating capability.
| Product group | Protecta Power Devices |
|---|---|
| Series | Tmax XT2 / Protecta Power |
| ABB order code | 1SDX253466R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 32 A |
| Number of poles | 3 |
| Pole configuration | 3P |
| Short-circuit breaking capacity | 36 kA |
| Breaking capacity classification | N (normal breaking capacity) |
| Trip unit type | TMA thermal-magnetic |
| Overload protection | Thermal trip mechanism |
| Short-circuit protection | Magnetic trip mechanism |
| Frame family | XT2 |
| Frame rating | 160 A |
| Application | Low-voltage electrical distribution |
| Installation type | Electrical distribution board / switchgear assembly |
| Operating mechanism | Manual toggle-operated circuit breaker |
| Applicable circuit breaker standard | IEC/EN 60947-2 |
| Typical system | Three-phase AC electrical distribution |
The ABB EPX-XT2N-TM0323 is a three-pole moulded case circuit breaker used to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for compatible commercial and industrial distribution assemblies, including ABB Protecta Power systems.
The EPX-XT2N-TM0323 has a 32 A rated current and is designed to protect appropriately rated electrical circuits against excessive current.
The ABB EPX-XT2N-TM0323 has a specified 36 kA short-circuit breaking capacity. This indicates its fault-interruption capability under the applicable rated test conditions. Suitability must be checked against the installation voltage and prospective fault current.
TMA thermal-magnetic protection combines a thermal overload protection element with a magnetic short-circuit protection element. The thermal mechanism responds to sustained excessive current, while the magnetic mechanism trips rapidly when a sufficiently high fault current occurs.
Yes. The three-pole (3P) configuration allows the breaker to protect and switch three phase conductors together, making it suitable for appropriately designed three-phase low-voltage distribution circuits.
The ABB manufacturer order code is 1SDX253466R1. The corresponding product reference is EPX-XT2N-TM0323, identifying the 32 A, three-pole, 36 kA thermal-magnetic MCCB within the Protecta Power Devices range.
This MCCB is typically installed within compatible electrical distribution boards, switchgear assemblies and commercial or industrial distribution panels. It is particularly relevant to ABB Protecta Power installations requiring three-pole outgoing circuit protection.
ABB Protecta Power circuit protection devices combine established Tmax XT circuit breaker technology with practical integration into modern electrical distribution systems. The EPX-XT2N-TM0323 offers dependable 32 A three-pole thermal-magnetic protection and a 36 kA breaking capacity for appropriately specified commercial and industrial installations.