Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT1N-TM1253 (1SDX253317R1) is a 125 A three-pole SACE Tmax XT1N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power electrical distribution systems.
£435.70
The ABB EPX-XT1N-TM1253 is a compact and dependable 125 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT1N160 circuit breaker platform, this protective device combines robust electrical protection with a space-efficient design for commercial and industrial power distribution installations.
As part of the ABB Protecta Power Devices product group, the EPX-XT1N-TM1253 is designed for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip configuration provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The three-pole construction enables simultaneous switching of all three phase conductors in suitable electrical installations.
With a rated current of 125 A, a specified 36 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT1N-TM1253 is suitable for outgoing feeder protection and three-phase electrical distribution circuits. Its compact 80 mm nominal device width supports efficient use of distribution board space, making it a practical solution for electrical contractors, switchboard manufacturers, panel builders and facilities engineers.
Moulded case circuit breakers such as the ABB EPX-XT1N-TM1253 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained overcurrent, while the magnetic protection element operates rapidly during short-circuit faults. This combined protection helps reduce the risk of cable damage, equipment failure and disruption to electrical distribution infrastructure.
The ABB SACE Tmax XT1N160 platform provides dependable low-voltage circuit protection in a compact moulded case design. Its three-pole configuration enables coordinated switching and protection of all three phase conductors, making the EPX-XT1N-TM1253 suitable for three-phase outgoing feeders and distribution circuits. The thermal-magnetic trip system supports appropriate protection coordination with connected cables, electrical loads and downstream protective devices.
The 125 A rated current makes this breaker suitable for appropriately designed outgoing feeders and electrical circuits, while its 36 kA specified breaking capacity provides short-circuit interruption capability for compatible distribution applications. The 80 mm nominal width helps optimise available space within electrical distribution boards, making the device suitable for new installations and upgrades to existing ABB Protecta Power assemblies.
Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing and protective device coordination. The applicable breaking capacity, thermal-magnetic trip settings and mounting accessories should be assessed against the complete electrical installation design and relevant ABB technical documentation.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT |
| Circuit breaker platform | XT1N160 |
| ABB order code | 1SDX253317R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 125 A |
| Frame rating | 160 A |
| Breaking capacity | 36 kA (specified Protecta Power application) |
| Number of poles | 3 |
| Pole configuration | Three-pole (3P) |
| Trip configuration | Thermal-magnetic adjustable (TMA) |
| Trip technology | Thermal-magnetic |
| Thermal protection | Overload protection |
| Magnetic protection | Short-circuit protection |
| Protection functions | Overload and short-circuit protection |
| Applicable standard | IEC 60947-2 |
| Nominal device width | 80 mm |
| Mounting type | Compatible ABB Protecta Power distribution assembly |
| Installation | Fixed distribution board installation using compatible mounting and connection accessories |
| Application | Three-phase low-voltage electrical power distribution |
The ABB EPX-XT1N-TM1253 is a 125 A three-pole moulded case circuit breaker designed to protect three-phase electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.
The EPX-XT1N-TM1253 has a 125 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT1N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be assessed against the installation voltage and prospective fault current.
TMA stands for Thermal-Magnetic Adjustable. This protection technology combines a thermal element for sustained overload conditions with a magnetic element for short-circuit faults. The thermal-magnetic trip characteristics support protection coordination with electrical cables and connected equipment. Exact adjustment capabilities depend on the specific ABB XT1N160 trip unit configuration.
The three-pole (3P) configuration enables the circuit breaker to protect and switch three phase conductors simultaneously. This makes the EPX-XT1N-TM1253 suitable for three-phase electrical distribution circuits and appropriately designed three-phase equipment supplies. Unlike a four-pole breaker, it does not provide a dedicated switched neutral pole.
The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. The ABB XT1N three-pole platform has a nominal width of 80 mm, making it suitable for compact electrical distribution assemblies. Compatible mounting and connection accessories should be selected for the installation.
ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT1N-TM1253 combines 125 A circuit protection, three-pole switching, 36 kA specified short-circuit breaking capacity and thermal-magnetic protection to support reliable electrical installations in commercial and industrial ABB Protecta Power distribution systems.