ABB EPX-XT1N-TM0803 Protecta Power 80 A three-pole Tmax XT1N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.

SKU: 1SDX253313R1Alt SKU: EPX-XT1N-TM0803MPN: 1SDX253313R1
Price
List Price £357.48 ex VAT
Your Price (ex VAT)
£357.48
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £357.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£357.48

Why Choose the ABB EPX-XT1N-TM0803 80A 3-Pole 36kA MCCB with TMA Protection?

The ABB EPX-XT1N-TM0803 is an 80 A, three-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution circuits against overloads and short-circuit faults. Part of the ABB Tmax XT1N circuit breaker family and the Protecta Power Devices range, this MCCB combines compact construction with a 36 kA specified breaking capacity and thermal-magnetic protection for commercial and industrial applications.

Featuring a TMA thermal-magnetic trip unit, the EPX-XT1N-TM0803 provides thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element enables rapid interruption when sufficiently high fault currents occur. These complementary functions help protect conductors, connected equipment and electrical distribution infrastructure against damaging overcurrent conditions.

With its 80 A rated current, three-pole configuration and compact XT1N construction, the EPX-XT1N-TM0803 is suitable for appropriately designed three-phase outgoing circuits. Its Protecta Power configuration supports integration into compatible ABB electrical distribution assemblies, making it a practical choice for electrical contractors, engineers and panel builders requiring dependable circuit protection.

Key Advantages

  • 80 A rated current provides protection for suitably rated three-phase distribution circuits.
  • Three-pole construction enables coordinated switching and protection across three phases.
  • 36 kA specified breaking capacity supports installations with appropriate prospective short-circuit current levels.
  • TMA thermal-magnetic protection combines overload and short-circuit protective functions.
  • ABB Tmax XT1N technology provides established moulded case circuit breaker performance.
  • Compact XT1 construction supports efficient use of space within electrical distribution equipment.
  • Protecta Power compatibility enables integration into designated ABB distribution assemblies.
  • Manual switching and resetting supports straightforward operation and maintenance.
  • Three-phase circuit protection makes the device suitable for commercial, industrial and building services applications.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT1N moulded case circuit breaker.
  • 80 A rated current.
  • Three-pole circuit breaker configuration.
  • 36 kA specified breaking capacity.
  • TMA thermal-magnetic trip technology.
  • Thermal overload protection against sustained overcurrent conditions.
  • Magnetic short-circuit protection against high fault currents.
  • Common operating mechanism for coordinated three-pole switching.
  • Manual opening, closing and resetting following a protective trip.
  • XT1 three-pole device width: 80 mm.
  • XT1 frame current class: 160 A.
  • Designed for installation within compatible ABB Protecta Power distribution assemblies.
  • Suitable for three-phase outgoing feeder and distribution circuit protection.
  • ABB manufacturer order code 1SDX253313R1.

Reliable Thermal-Magnetic Protection for Three-Phase Power Distribution

The ABB EPX-XT1N-TM0803 provides circuit protection for three-phase electrical installations requiring an 80 A moulded case circuit breaker. Its TMA thermal-magnetic trip arrangement responds to sustained overload currents and short-circuit faults. Thermal protection helps prevent excessive conductor heating during prolonged overcurrent conditions, while magnetic protection provides rapid tripping when sufficiently high fault currents occur.

The ABB Tmax XT1N platform provides a compact protective solution for compatible Protecta Power panelboards and distribution assemblies. Its 80 mm three-pole width supports efficient panelboard layout, while the 160 A frame class identifies the circuit breaker platform rather than the device's actual 80 A protective rating. The specified 36 kA breaking capacity must be assessed against the prospective short-circuit current and operating voltage of the installation. Electrical designers should also verify conductor sizing, protective coordination, trip characteristics, terminal arrangements and assembly compatibility.

Typical Applications

  • ABB Protecta Power electrical distribution assemblies.
  • Commercial and industrial low-voltage distribution boards.
  • Three-phase outgoing feeder protection.
  • Sub-distribution boards and electrical panel installations.
  • Manufacturing facilities and industrial workshops.
  • Commercial buildings, offices and retail premises.
  • Warehouses and logistics facilities.
  • Electrical plant rooms and building services installations.
  • Distribution circuits supplying industrial machinery and equipment.
  • Panel building projects requiring 80 A three-pole MCCB protection.
  • Electrical installations requiring a 36 kA thermal-magnetic circuit breaker.

Technical Specifications

Product model EPX-XT1N-TM0803
ABB order code 1SDX253313R1
Product group Protecta Power Devices
Circuit breaker series Tmax XT
Circuit breaker family XT1N
Frame designation XT1
Frame current class 160 A
Product type Moulded case circuit breaker (MCCB)
Rated current 80 A
Number of poles 3
Specified breaking capacity 36 kA
Trip unit designation TMA
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Device width 80 mm
Operating mechanism Manual circuit breaker operation
Electrical system Low-voltage electrical distribution
Distribution arrangement Three-pole, three-phase applications
Installation Compatible ABB Protecta Power distribution assembly
Primary application Overload and short-circuit protection

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0803 used for?

The ABB EPX-XT1N-TM0803 is an 80 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.

What is the current rating and breaking capacity of the EPX-XT1N-TM0803?

The EPX-XT1N-TM0803 has an 80 A rated current and a specified 36 kA breaking capacity. The applicable short-circuit breaking capacity must be verified against the operating voltage and prospective fault current of the installation.

What does TMA mean on the ABB EPX-XT1N-TM0803?

TMA identifies the thermal-magnetic trip unit configuration. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. Exact trip adjustment ranges and operating characteristics should be confirmed using the relevant ABB technical documentation.

What are the frame rating and width of the ABB EPX-XT1N-TM0803?

The EPX-XT1N-TM0803 belongs to the 160 A XT1 frame class but has an actual rated current of 80 A. The ABB Protecta Power XT1 three-pole configuration has a specified device width of 80 mm. Installers should also allow for the required wiring space, electrical clearances and mounting arrangements.

What is the difference between the EPX-XT1N-TM0803 and EPX-XT1S-TM0803?

Both models are 80 A three-pole ABB Tmax XT1 thermal-magnetic MCCBs. The EPX-XT1N-TM0803 has a specified 36 kA breaking capacity, while the EPX-XT1S-TM0803 has a specified 50 kA breaking capacity. Selection depends on the prospective short-circuit current, operating voltage and protective requirements of the installation.

Trusted by Electrical Contractors and Panel Builders

ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage circuit protection. The EPX-XT1N-TM0803 combines an 80 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.