ABB EPX-XT1N-TM0803 Protecta Power 80 A three-pole Tmax XT1N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.
£357.48
The ABB EPX-XT1N-TM0803 is an 80 A, three-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution circuits against overloads and short-circuit faults. Part of the ABB Tmax XT1N circuit breaker family and the Protecta Power Devices range, this MCCB combines compact construction with a 36 kA specified breaking capacity and thermal-magnetic protection for commercial and industrial applications.
Featuring a TMA thermal-magnetic trip unit, the EPX-XT1N-TM0803 provides thermal overload protection and magnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic element enables rapid interruption when sufficiently high fault currents occur. These complementary functions help protect conductors, connected equipment and electrical distribution infrastructure against damaging overcurrent conditions.
With its 80 A rated current, three-pole configuration and compact XT1N construction, the EPX-XT1N-TM0803 is suitable for appropriately designed three-phase outgoing circuits. Its Protecta Power configuration supports integration into compatible ABB electrical distribution assemblies, making it a practical choice for electrical contractors, engineers and panel builders requiring dependable circuit protection.
The ABB EPX-XT1N-TM0803 provides circuit protection for three-phase electrical installations requiring an 80 A moulded case circuit breaker. Its TMA thermal-magnetic trip arrangement responds to sustained overload currents and short-circuit faults. Thermal protection helps prevent excessive conductor heating during prolonged overcurrent conditions, while magnetic protection provides rapid tripping when sufficiently high fault currents occur.
The ABB Tmax XT1N platform provides a compact protective solution for compatible Protecta Power panelboards and distribution assemblies. Its 80 mm three-pole width supports efficient panelboard layout, while the 160 A frame class identifies the circuit breaker platform rather than the device's actual 80 A protective rating. The specified 36 kA breaking capacity must be assessed against the prospective short-circuit current and operating voltage of the installation. Electrical designers should also verify conductor sizing, protective coordination, trip characteristics, terminal arrangements and assembly compatibility.
| Product model | EPX-XT1N-TM0803 |
|---|---|
| ABB order code | 1SDX253313R1 |
| Product group | Protecta Power Devices |
| Circuit breaker series | Tmax XT |
| Circuit breaker family | XT1N |
| Frame designation | XT1 |
| Frame current class | 160 A |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 80 A |
| Number of poles | 3 |
| Specified breaking capacity | 36 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Device width | 80 mm |
| Operating mechanism | Manual circuit breaker operation |
| Electrical system | Low-voltage electrical distribution |
| Distribution arrangement | Three-pole, three-phase applications |
| Installation | Compatible ABB Protecta Power distribution assembly |
| Primary application | Overload and short-circuit protection |
The ABB EPX-XT1N-TM0803 is an 80 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.
The EPX-XT1N-TM0803 has an 80 A rated current and a specified 36 kA breaking capacity. The applicable short-circuit breaking capacity must be verified against the operating voltage and prospective fault current of the installation.
TMA identifies the thermal-magnetic trip unit configuration. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. Exact trip adjustment ranges and operating characteristics should be confirmed using the relevant ABB technical documentation.
The EPX-XT1N-TM0803 belongs to the 160 A XT1 frame class but has an actual rated current of 80 A. The ABB Protecta Power XT1 three-pole configuration has a specified device width of 80 mm. Installers should also allow for the required wiring space, electrical clearances and mounting arrangements.
Both models are 80 A three-pole ABB Tmax XT1 thermal-magnetic MCCBs. The EPX-XT1N-TM0803 has a specified 36 kA breaking capacity, while the EPX-XT1S-TM0803 has a specified 50 kA breaking capacity. Selection depends on the prospective short-circuit current, operating voltage and protective requirements of the installation.
ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage circuit protection. The EPX-XT1N-TM0803 combines an 80 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.