1SDX253311R1 ABB EPX-XT1N-TM0503 Protecta Power XT1N 50A 3-Pole 36kA TMA MCCB

1SDX253311R1 ABB EPX-XT1N-TM0503 Protecta Power XT1N 50A 3-Pole 36kA TMA MCCB

ABB EPX-XT1N-TM0503 Protecta Power 50 A three-pole Tmax XT1N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.

SKU: 1SDX253311R1Alt SKU: EPX-XT1N-TM0503MPN: 1SDX253311R1
Price
List Price £348.06 ex VAT
Your Price (ex VAT)
£348.06
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £348.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£348.06

Why Choose the ABB EPX-XT1N-TM0503 50A 3-Pole 36kA MCCB with TMA Protection?

The ABB EPX-XT1N-TM0503 is a 50 A, three-pole moulded case circuit breaker (MCCB) designed to protect low-voltage electrical distribution circuits against overloads and short-circuit faults. Part of the ABB Tmax XT1N circuit breaker family and the Protecta Power Devices range, this MCCB combines a compact construction with a 36 kA specified breaking capacity and TMA thermal-magnetic protection.

Featuring a TMA thermal-magnetic trip unit, the EPX-XT1N-TM0503 provides thermal protection against sustained overload conditions and magnetic protection against short-circuit faults. These complementary protective functions help safeguard electrical conductors, connected equipment and distribution infrastructure against excessive current.

With its 50 A rated current, three-pole configuration and compact XT1N construction, the EPX-XT1N-TM0503 is suitable for appropriately designed three-phase outgoing circuits in commercial and industrial installations. Its Protecta Power configuration supports integration into compatible ABB distribution assemblies, making it a practical choice for electrical contractors, engineers and panel builders.

Key Advantages

  • 50 A rated current for individual three-phase outgoing circuit protection.
  • Three-pole construction provides coordinated switching and protection across three phases.
  • 36 kA specified breaking capacity supports installations with suitable prospective short-circuit current levels.
  • TMA thermal-magnetic protection combines overload and short-circuit protective functions.
  • ABB Tmax XT1N technology provides established moulded case circuit breaker performance.
  • Compact XT1 construction supports efficient use of space within electrical distribution assemblies.
  • Protecta Power compatibility supports installation within designated ABB distribution equipment.
  • Manual switching and resetting allows straightforward circuit breaker operation.
  • Suitable for commercial, industrial and building services electrical distribution applications.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT1N moulded case circuit breaker.
  • 50 A rated current.
  • Three-pole circuit breaker configuration.
  • 36 kA specified breaking capacity.
  • TMA thermal-magnetic trip technology.
  • Thermal overload protection against sustained overcurrent conditions.
  • Magnetic short-circuit protection against high fault currents.
  • Common operating mechanism for three-pole switching.
  • Manual opening, closing and resetting following a protective trip.
  • XT1 three-pole device width: 80 mm.
  • Designed for installation within compatible ABB Protecta Power distribution assemblies.
  • Suitable for three-phase outgoing feeder and distribution circuit protection.
  • ABB manufacturer order code 1SDX253311R1.

Reliable Thermal-Magnetic Protection for Three-Phase Distribution

The ABB EPX-XT1N-TM0503 provides circuit protection for three-phase electrical installations requiring a 50 A moulded case circuit breaker. Its TMA thermal-magnetic trip arrangement responds to sustained overload currents and short-circuit faults. Thermal protection helps prevent excessive conductor heating during prolonged overcurrent conditions, while magnetic protection provides rapid tripping when sufficiently high fault currents occur.

The ABB Tmax XT1N platform offers a compact protective solution for compatible Protecta Power panelboards and distribution assemblies. The three-pole device has an 80 mm width, supporting efficient panelboard layout. Its specified 36 kA breaking capacity must be assessed against the prospective short-circuit current and operating voltage of the installation. Electrical designers should also verify conductor sizing, protective coordination, trip characteristics, terminal arrangements and compatibility with the intended ABB distribution assembly.

Typical Applications

  • ABB Protecta Power electrical distribution assemblies.
  • Commercial and industrial low-voltage distribution boards.
  • Three-phase outgoing feeder protection.
  • Sub-distribution boards and electrical panel installations.
  • Manufacturing facilities and industrial workshops.
  • Commercial buildings, offices and retail premises.
  • Warehouses and logistics facilities.
  • Electrical plant rooms and building services installations.
  • Distribution circuits supplying industrial equipment.
  • Panel building projects requiring 50 A three-pole MCCB protection.
  • Electrical installations requiring a 36 kA thermal-magnetic circuit breaker.

Technical Specifications

Product model EPX-XT1N-TM0503
ABB order code 1SDX253311R1
Product group Protecta Power Devices
Circuit breaker series Tmax XT
Circuit breaker family XT1N
Frame designation XT1
Product type Moulded case circuit breaker (MCCB)
Rated current 50 A
Number of poles 3
Specified breaking capacity 36 kA
Trip unit designation TMA
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Device width 80 mm
Operating mechanism Manual circuit breaker operation
Electrical system Low-voltage electrical distribution
Distribution arrangement Three-pole, three-phase applications
Installation Compatible ABB Protecta Power distribution assembly
Primary application Overload and short-circuit protection

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0503 used for?

The ABB EPX-XT1N-TM0503 is a 50 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.

What is the current rating and breaking capacity of the EPX-XT1N-TM0503?

The EPX-XT1N-TM0503 has a 50 A rated current and a specified 36 kA breaking capacity. The applicable short-circuit breaking capacity must be verified against the installation's operating voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT1N-TM0503?

TMA identifies the thermal-magnetic trip unit configuration. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. Exact trip adjustment ranges and operating characteristics should be confirmed using the relevant ABB technical documentation.

What is the width of the ABB EPX-XT1N-TM0503?

The ABB Protecta Power XT1 three-pole device configuration has a specified width of 80 mm. Installers should also allow for the necessary wiring space, electrical clearances and mounting requirements within the distribution assembly.

What is the difference between the EPX-XT1N-TM0503 and EPX-XT1S-TM0503?

Both models are 50 A three-pole ABB Tmax XT1 thermal-magnetic MCCBs. The EPX-XT1N-TM0503 has a specified 36 kA breaking capacity, while the EPX-XT1S-TM0503 has a specified 50 kA breaking capacity. Selection depends on the prospective short-circuit current, operating voltage and protective requirements of the installation.

Trusted by Electrical Contractors and Panel Builders

ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage circuit protection. The EPX-XT1N-TM0503 combines a 50 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.