ABB EPX-XT1N-TM0163 is a 16 A three-pole SACE Tmax XT1N moulded case circuit breaker with 36 kA breaking capacity and TMA thermal-magnetic protection for commercial and industrial low-voltage distribution systems.
£348.06
The ABB EPX-XT1N-TM0163 is a compact and dependable 16 A three-pole moulded case circuit breaker (MCCB) designed for overload and short-circuit protection in commercial and industrial low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, this product incorporates the ABB SACE Tmax XT1N circuit breaker platform with thermal-magnetic protection, providing reliable circuit protection for compatible electrical distribution assemblies.
The EPX-XT1N-TM0163 combines robust circuit breaker construction with straightforward thermal-magnetic protection technology to safeguard electrical cables, connected equipment and distribution infrastructure. Its TMA thermal-magnetic trip arrangement provides protection against sustained overloads and short-circuit faults, helping reduce the risk of electrical damage and unplanned interruptions.
With a 16 A rated current, three-pole configuration and 36 kA short-circuit breaking capacity, the EPX-XT1N-TM0163 is suitable for three-phase outgoing circuits, commercial distribution boards and industrial electrical installations. Its compact 80 mm nominal width supports efficient integration into compatible ABB Protecta Power switchboard assemblies.
The ABB EPX-XT1N-TM0163 uses thermal-magnetic circuit protection technology to safeguard electrical installations against overloads and short circuits. The thermal element responds to sustained excessive current, helping prevent overheating of electrical conductors and connected equipment. The magnetic element responds rapidly to high short-circuit currents, disconnecting the affected circuit to limit potential damage.
The ABB SACE Tmax XT1N circuit breaker platform provides compact protection for low-voltage power distribution systems. Its three-pole construction allows simultaneous switching of three phase conductors, making it suitable for three-phase outgoing feeders and other compatible electrical distribution applications.
The EPX-XT1N-TM0163 is designed for integration into ABB Protecta Power distribution boards using suitable mounting and connection accessories. For Protecta Power outgoing MCCB installations, the compatible EPX-BPCXT1-3P base plate and cover should be selected separately where required. Correct cable sizing, prospective fault-current assessment and protective device coordination remain essential for safe installation.
| Product range | Protecta Power Devices |
|---|---|
| Circuit breaker series | SACE Tmax XT |
| Circuit breaker frame | XT1 |
| Performance level | XT1N |
| ABB order code | 1SDX253302R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 16 A |
| Frame rating | 160 A |
| Number of poles | 3P (three pole) |
| Short-circuit breaking capacity | 36 kA (specified Protecta Power application) |
| Trip unit designation | TMA thermal-magnetic |
| Trip technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Rated insulation voltage (Ui) | 800 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Nominal width | 80 mm |
| Applicable standard | IEC 60947-2 |
| Installation type | Electrical distribution board / switchboard mounting |
| Compatible system | ABB Protecta Power |
| Product category | Protecta Power Devices |
The ABB EPX-XT1N-TM0163 is a 16 A three-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in commercial and industrial installations.
The EPX-XT1N-TM0163 has a 16 A rated current and uses the ABB SACE Tmax XT1N circuit breaker platform with a 160 A frame rating.
The EPX-XT1N-TM0163 is specified with a 36 kA short-circuit breaking capacity for the ABB Protecta Power application. The applicable operating voltage and installation conditions must be considered when confirming the required fault-interruption capability.
TMA identifies a thermal-magnetic protection arrangement that combines thermal overload protection with magnetic short-circuit protection. This technology helps protect electrical conductors and connected equipment against excessive current and electrical faults.
The 16 A rated current identifies the current rating of this circuit breaker configuration, while the 160 A frame rating identifies the maximum frame capacity of the ABB Tmax XT1 platform. The 160 A frame rating does not mean this 16 A device can continuously carry 160 A.
For compatible ABB Protecta Power outgoing MCCB installations, the EPX-BPCXT1-3P base plate and cover are specified as separate components. The complete assembly should be selected according to the distribution board configuration.
Yes. The three-pole configuration allows switching and protection of three phase conductors, making the circuit breaker suitable for compatible three-phase low-voltage distribution circuits where a 16 A protective device is required.
ABB SACE Tmax XT moulded case circuit breakers provide dependable overload and short-circuit protection for commercial and industrial electrical installations. The EPX-XT1N-TM0163 combines a 16 A three-pole XT1N circuit breaker with 36 kA breaking capacity and TMA thermal-magnetic protection, delivering a compact and reliable solution for compatible ABB Protecta Power distribution assemblies.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.