1SDX248671R1 ABB EPX-XT1S-TM0324 32A 4-Pole 50kA MCCB TMA

1SDX248671R1 ABB EPX-XT1S-TM0324 32A 4-Pole 50kA MCCB TMA

ABB EPX-XT1S-TM0324 is a 32 A four-pole moulded case circuit breaker from the Protecta Power Devices range, featuring an XT1S frame, 50 kA short-circuit breaking capacity and TMA thermal-magnetic adjustable protection for low-voltage electrical distribution systems.

SKU: 1SDX248671R1Alt SKU: EPX-XT1S-TM0324MPN: 1SDX248671R1
Price
List Price £508.39 ex VAT
Your Price (ex VAT)
£508.39
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £508.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£508.39

Why Choose the ABB EPX-XT1S-TM0324 32A 4-Pole MCCB?

The ABB EPX-XT1S-TM0324 is a compact and dependable 32 A 4-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices product group, this circuit breaker features an XT1S frame and thermal-magnetic adjustable (TMA) trip unit, making it suitable for commercial buildings, industrial installations and electrical distribution assemblies.

The EPX-XT1S-TM0324 combines thermal overload protection with magnetic short-circuit protection to help safeguard electrical circuits, cables and connected equipment against excessive current and electrical faults. Its four-pole construction supports the switching of three-phase circuits incorporating a neutral conductor, making it particularly suitable for modern power distribution systems requiring coordinated circuit protection and isolation.

With a 32 A rated current, 50 kA short-circuit breaking capacity and 4-pole configuration, the ABB EPX-XT1S-TM0324 provides a robust protection solution for appropriately designed low-voltage installations. Its compact XT1S construction allows efficient integration into compatible ABB Protecta Power distribution boards, switchgear assemblies and electrical control panels.

Key Advantages

  • Reliable 32 A moulded case circuit breaker for low-voltage power distribution.
  • 4-pole configuration suitable for three-phase electrical systems with a neutral conductor.
  • 50 kA short-circuit breaking capacity for demanding electrical protection requirements.
  • Integrated thermal-magnetic adjustable (TMA) trip unit for overload and short-circuit protection.
  • Compact ABB XT1S frame supports efficient installation within electrical distribution assemblies.
  • Thermal protection helps prevent damage caused by sustained overload conditions.
  • Magnetic protection provides rapid circuit interruption during significant short-circuit faults.
  • Manual switching mechanism supports circuit isolation and resetting after a protective trip.
  • Suitable for integration into compatible ABB Protecta Power distribution systems.
  • Robust moulded case construction supports dependable operation in commercial and industrial environments.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT1S-TM0324 moulded case circuit breaker.
  • XT1S frame for compact low-voltage circuit protection.
  • 32 A rated current.
  • 4-pole circuit breaker configuration.
  • 50 kA short-circuit breaking capacity.
  • TMA thermal-magnetic adjustable trip unit.
  • Thermal overload protection for sustained overcurrent conditions.
  • Magnetic short-circuit protection for high fault currents.
  • Manual operating mechanism with circuit breaker status indication.
  • Compact four-pole construction with a nominal frame width of 110 mm.
  • Designed for use in compatible low-voltage electrical distribution boards and switchgear assemblies.
  • Suitable for commercial, industrial and building electrical distribution applications.

Technical Specifications

  • Manufacturer: ABB
  • Product group: Protecta Power Devices
  • Series / Frame: XT1S
  • Model: EPX-XT1S-TM0324
  • ABB order code: 1SDX248671R1
  • Product type: Moulded case circuit breaker (MCCB)
  • Rated current: 32 A
  • Number of poles: 4
  • Short-circuit breaking capacity: 50 kA
  • Trip unit: TMA – Thermal Magnetic Adjustable
  • Overload protection: Thermal trip protection
  • Short-circuit protection: Magnetic trip protection
  • Frame width: 110 mm
  • Application: Low-voltage electrical distribution
  • Operating mechanism: Manual circuit breaker operation
  • Construction: Moulded case
  • Mounting application: Compatible electrical distribution boards and switchgear assemblies
  • Installation environment: Enclosed low-voltage electrical distribution equipment
  • Product classification: Low-voltage circuit protection device

Reliable Circuit Protection for Low-Voltage Electrical Systems

Moulded case circuit breakers such as the ABB EPX-XT1S-TM0324 are essential components in modern electrical distribution installations. They protect electrical circuits by automatically interrupting the current when overload or short-circuit conditions occur. This helps reduce the risk of damage to electrical cables, distribution equipment and connected loads while supporting safer and more reliable electrical operation.

The TMA thermal-magnetic trip unit combines two complementary protection technologies. The thermal element responds to sustained overload currents, while the magnetic element operates during significant short-circuit conditions. This combination provides dependable overcurrent protection without requiring an external electronic trip controller.

The 32 A four-pole XT1S configuration is particularly suitable for three-phase electrical distribution systems incorporating a neutral conductor. Its compact construction supports efficient use of available space within electrical panels, while its 50 kA breaking capacity provides substantial short-circuit interruption capability under the applicable rated conditions.

As part of the ABB Protecta Power Devices range, the EPX-XT1S-TM0324 is designed for integration into compatible low-voltage distribution equipment. Electrical engineers and installers can use this circuit breaker in appropriately specified commercial and industrial installations where reliable circuit protection, isolation and maintainability are important.

Correct selection and installation should account for the electrical system voltage, prospective short-circuit current, conductor sizing, protective device coordination and applicable wiring regulations. The suitability of the breaker for a particular installation must be assessed against the relevant electrical design requirements.

Typical Applications

  • Low-voltage electrical distribution boards.
  • ABB Protecta Power distribution assemblies.
  • Commercial building electrical installations.
  • Industrial power distribution systems.
  • Three-phase distribution circuits with neutral conductors.
  • Electrical switchboards and control panels.
  • Sub-distribution boards and outgoing feeder circuits.
  • Manufacturing plants and production facilities.
  • Warehouses, offices and commercial premises.
  • Building services and electrical infrastructure installations.
  • Electrical systems requiring 32 A four-pole circuit protection.

Frequently Asked Questions

What is the ABB EPX-XT1S-TM0324 used for?

The ABB EPX-XT1S-TM0324 is a moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits. It is suitable for commercial and industrial distribution boards, switchgear assemblies and three-phase electrical installations.

What is the rated current of the ABB EPX-XT1S-TM0324?

The circuit breaker has a 32 A rated current, making it suitable for appropriately designed electrical distribution circuits requiring a 32 A MCCB with thermal-magnetic protection.

What is the short-circuit breaking capacity of this MCCB?

The ABB EPX-XT1S-TM0324 has a specified 50 kA short-circuit breaking capacity. This represents its short-circuit interruption capability under the applicable rated conditions. The system voltage and prospective fault current must be considered when confirming suitability for an installation.

What type of trip unit does the ABB EPX-XT1S-TM0324 use?

This circuit breaker incorporates a TMA thermal-magnetic adjustable trip unit. The thermal element provides overload protection, while the magnetic element responds to short-circuit conditions, helping protect electrical circuits and connected equipment against excessive current.

How many poles does the ABB EPX-XT1S-TM0324 have?

The ABB EPX-XT1S-TM0324 is a 4-pole MCCB, suitable for low-voltage distribution applications requiring four-pole switching, including three-phase electrical circuits incorporating a neutral conductor.

Trusted by Electrical Engineers and Installers Worldwide

ABB Protecta Power Devices provide dependable circuit protection solutions for modern commercial and industrial electrical distribution systems. The ABB EPX-XT1S-TM0324 combines a compact XT1S frame, 32 A rated current, four-pole construction, 50 kA breaking capacity and TMA thermal-magnetic protection to support reliable operation in low-voltage electrical installations.