1SDX248664R1 ABB EPX-XT1N-TM1004 100A 4-Pole 36kA Thermal-Magnetic MCCB Tmax XT1N Protecta Power

1SDX248664R1 ABB EPX-XT1N-TM1004 100A 4-Pole 36kA Thermal-Magnetic MCCB Tmax XT1N Protecta Power

ABB EPX-XT1N-TM1004 is a 100 A four-pole Tmax XT1N160 moulded case circuit breaker with a 36 kA breaking-capacity classification and thermal-magnetic overload and short-circuit protection for compatible ABB Protecta Power low-voltage distribution assemblies.

SKU: 1SDX248664R1Alt SKU: EPX-XT1N-TM1004MPN: 1SDX248664R1
Price
List Price £557.62 ex VAT
Your Price (ex VAT)
£557.62
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £557.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£557.62

ABB EPX-XT1N-TM1004 100A 4-Pole 36kA Thermal-Magnetic MCCB

The ABB EPX-XT1N-TM1004 is a 100 A, four-pole moulded case circuit breaker (MCCB) designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies. Based on the established ABB SACE Tmax XT1N160 circuit breaker platform, this device combines a 36 kA breaking-capacity classification with thermal-magnetic protection for commercial and industrial electrical installations.

Featuring a four-pole (4P) configuration, the EPX-XT1N-TM1004 provides coordinated switching of three phase conductors and a neutral conductor in appropriately designed three-phase, four-wire electrical systems. Its 100 A rated current makes it suitable for distribution feeders, sub-distribution circuits and electrical installations requiring compact, reliable overcurrent protection.

The circuit breaker uses thermal-magnetic protection, combining a thermal element that responds to sustained overload currents with a magnetic element that responds to short-circuit faults. ABB's Protecta Power product description identifies this configuration as TMA, while the corresponding XT1N160 100 A protective device is listed within the manufacturer's thermal-magnetic outgoing breaker range. The precise trip characteristics and available adjustments should be confirmed against the supplied device markings.

Identified by ABB order code 1SDX248664R1, the EPX-XT1N-TM1004 belongs to the ABB Protecta Power Devices range. Its combination of compact XT1N construction, four-pole switching and a 36 kA fault-interruption classification makes it a practical solution for professional distribution panelboard installations.

Key Advantages

  • 100 A rated current: Provides overload and short-circuit protection for appropriately designed electrical distribution circuits.
  • Four-pole construction: Supports coordinated switching of three phase conductors and neutral in suitable installations.
  • 36 kA breaking-capacity classification: Offers substantial short-circuit interruption capability at the applicable operating voltage.
  • ABB Tmax XT1N technology: Uses an established moulded case circuit breaker platform for low-voltage power distribution.
  • Thermal-magnetic protection: Combines overload and short-circuit protective functions within one compact device.
  • 160 A frame family: Provides the mechanical platform for the specified 100 A protective device.
  • Compact four-pole design: Helps electrical panel builders make efficient use of distribution board space.
  • Protecta Power compatibility: Designed for integration into suitable ABB outgoing MCCB arrangements.
  • Manual switching operation: Enables circuit breaker operation and resetting following an appropriate inspection.
  • Manufacturer-matched selection: Supports consistent specification of protective devices within ABB distribution assemblies.

Key Features

  • ABB EPX-XT1N-TM1004 outgoing moulded case circuit breaker.
  • 100 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA Protecta Power breaking-capacity classification.
  • ABB SACE Tmax XT1N160 circuit breaker family.
  • 160 A frame-current designation.
  • Thermal-magnetic overcurrent protection.
  • Thermal response to sustained overload conditions.
  • Magnetic response to short-circuit faults.
  • TMA designation in the supplied Protecta Power product specification.
  • Four-pole switching for suitable three-phase, four-wire distribution systems.
  • Compact moulded case construction.
  • Manual circuit breaker operating mechanism.
  • 110 mm nominal four-pole XT1 device width.
  • Designed for compatible ABB Protecta Power outgoing circuit arrangements.
  • Suitable for commercial and industrial low-voltage distribution applications.

Reliable 100A Circuit Protection with ABB Tmax XT1N Technology

The ABB EPX-XT1N-TM1004 provides thermal-magnetic overcurrent protection for suitably rated electrical distribution circuits. Its compact Tmax XT1N160 construction is particularly useful in compatible Protecta Power panelboards where effective circuit protection must be combined with efficient use of available installation space.

The thermal protection element responds to sustained overload currents. If a circuit carries excessive current for a sufficient period, the thermal mechanism initiates operation of the breaker, helping reduce the risk of excessive conductor heating and damage to connected equipment.

The magnetic protection element responds to short-circuit conditions. When fault current reaches the breaker's magnetic operating threshold, the protective mechanism trips to interrupt the circuit. The precise operating characteristic must be checked against the manufacturer's technical information for the fitted device.

The supplied Protecta Power specification identifies the EPX-XT1N-TM1004 with the TMA thermal-magnetic designation. Because ABB offers different thermal-magnetic release arrangements across the Tmax XT family, installers should confirm whether the supplied breaker has fixed or adjustable settings rather than assuming a particular adjustment range.

The four-pole arrangement allows coordinated switching of three phase conductors and a neutral conductor in suitable electrical systems. Neutral protection, neutral switching requirements and the earthing arrangement must be considered during the design process, particularly when selecting protection for three-phase, four-wire distribution circuits.

The 36 kA breaking-capacity classification is an important consideration when selecting a circuit breaker for installations with substantial prospective fault currents. The actual ultimate and service short-circuit breaking capacities must be verified at the relevant system voltage, and the device must be suitable for the installation's calculated fault level.

The ABB Tmax XT1N160 frame provides a compact mechanical design. ABB identifies a nominal width of 110 mm for four-pole XT1 outgoing devices in its Protecta Power selection information. This supports efficient distribution board planning, although the completed installation must also allow adequate space for cable connections, protective covers and maintenance access.

For integration into ABB Protecta Power distribution assemblies, the correct MCCB mounting arrangement, connection components and protective covers must be selected. The compatibility of the breaker and the panelboard should be verified using the relevant ABB selection and installation documentation.

Electrical designers should also assess conductor current-carrying capacity, terminal suitability, installation temperature, fault protection and coordination with upstream protective devices. The completed assembly must be installed and tested in accordance with the applicable electrical installation requirements.

Combining a 100 A rated current, four-pole construction and established ABB thermal-magnetic protection technology, the EPX-XT1N-TM1004 provides a practical outgoing MCCB solution for commercial, industrial and building services distribution applications.

Typical Applications

  • ABB Protecta Power outgoing circuit protection.
  • 100 A three-phase electrical distribution circuits.
  • Three-phase, four-wire electrical installations.
  • Commercial low-voltage distribution panelboards.
  • Industrial electrical distribution assemblies.
  • Office buildings and commercial developments.
  • Retail premises and shopping facilities.
  • Warehouses and logistics centres.
  • Building services electrical installations.
  • Suitable machinery and fixed equipment supply circuits.
  • Electrical sub-distribution boards.
  • Distribution board refurbishment and maintenance.
  • Professional electrical panel building and switchgear assembly.

Technical Specifications

Product group Protecta Power Devices
Product model EPX-XT1N-TM1004
ABB order code 1SDX248664R1
Product type Moulded case circuit breaker (MCCB)
Circuit breaker range ABB SACE Tmax XT
Circuit breaker family XT1N
Frame designation XT1N160
Frame-current designation 160 A
Rated current 100 A
Number of poles 4
Pole configuration Four-pole (4P)
Breaking-capacity classification 36 kA, subject to the manufacturer's applicable operating-voltage conditions
Protecta Power trip designation TMA
Protection technology Thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Operating mechanism Manual
Nominal four-pole XT1 device width 110 mm
Circuit breaker standard IEC 60947-2
Corresponding ABB protective device reference 1SDA067424R1
Compatible distribution system ABB Protecta Power
Related 80 A four-pole model EPX-XT1N-TM0804
Related 125 A four-pole model EPX-XT1N-TM1254
Related 100 A three-pole model EPX-XT1N-TM1003
Related 100 A XT4N four-pole model EPX-XT4N-TM1004
Primary application Outgoing circuit protection in compatible low-voltage distribution assemblies

Frequently Asked Questions

What is the ABB EPX-XT1N-TM1004 used for?

The ABB EPX-XT1N-TM1004 is a 100 A four-pole thermal-magnetic MCCB designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies.

What is the rated current of the EPX-XT1N-TM1004?

The EPX-XT1N-TM1004 has a rated current of 100 A and belongs to the ABB Tmax XT1N160 circuit breaker family, which uses a 160 A frame designation.

What is the breaking capacity of the EPX-XT1N-TM1004?

The EPX-XT1N-TM1004 has a 36 kA breaking-capacity classification in the ABB Protecta Power range. The applicable breaking capacity must be confirmed at the installation's operating voltage.

Is the EPX-XT1N-TM1004 a four-pole circuit breaker?

Yes. The EPX-XT1N-TM1004 is a four-pole (4P) MCCB suitable for appropriately designed three-phase distribution systems requiring coordinated four-pole switching.

What does TMA mean on the ABB EPX-XT1N-TM1004?

TMA is the thermal-magnetic trip designation included in the supplied Protecta Power product specification. The actual protective settings and whether adjustment is available must be confirmed from the markings and technical documentation of the supplied breaker.

Does the EPX-XT1N-TM1004 provide overload and short-circuit protection?

Yes. The circuit breaker uses thermal-magnetic protection, providing a thermal response to sustained overload currents and a magnetic response to short-circuit faults.

What is the difference between EPX-XT1N-TM1004 and EPX-XT1N-TM1003?

The EPX-XT1N-TM1004 is a 100 A four-pole circuit breaker, while the EPX-XT1N-TM1003 is the corresponding 100 A three-pole version. Both belong to the ABB Tmax XT1N Protecta Power outgoing device range.

What is the difference between EPX-XT1N-TM1004 and EPX-XT1N-TM0804?

The EPX-XT1N-TM1004 has a rated current of 100 A, while the EPX-XT1N-TM0804 has a rated current of 80 A. Both are four-pole ABB Tmax XT1N thermal-magnetic MCCB configurations with a 36 kA breaking-capacity classification.

Can the EPX-XT1N-TM1004 be installed in ABB Protecta Power panelboards?

Yes. The EPX-XT1N-TM1004 belongs to the ABB Protecta Power Devices range and is intended for compatible distribution assemblies. The appropriate mounting arrangement, connections and protective covers must be confirmed before installation.

Trusted by Electrical Contractors and Panel Builders

ABB Protecta Power moulded case circuit breakers offer a coordinated approach to low-voltage electrical distribution. The EPX-XT1N-TM1004 combines a 100 A rating, four-pole Tmax XT1N construction and 36 kA breaking-capacity classification, supporting electrical contractors and panel builders in creating dependable, professionally assembled distribution systems.