Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT1N-TM1004 is a 100 A four-pole Tmax XT1N160 moulded case circuit breaker with a 36 kA breaking-capacity classification and thermal-magnetic overload and short-circuit protection for compatible ABB Protecta Power low-voltage distribution assemblies.
£557.62
The ABB EPX-XT1N-TM1004 is a 100 A, four-pole moulded case circuit breaker (MCCB) designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies. Based on the established ABB SACE Tmax XT1N160 circuit breaker platform, this device combines a 36 kA breaking-capacity classification with thermal-magnetic protection for commercial and industrial electrical installations.
Featuring a four-pole (4P) configuration, the EPX-XT1N-TM1004 provides coordinated switching of three phase conductors and a neutral conductor in appropriately designed three-phase, four-wire electrical systems. Its 100 A rated current makes it suitable for distribution feeders, sub-distribution circuits and electrical installations requiring compact, reliable overcurrent protection.
The circuit breaker uses thermal-magnetic protection, combining a thermal element that responds to sustained overload currents with a magnetic element that responds to short-circuit faults. ABB's Protecta Power product description identifies this configuration as TMA, while the corresponding XT1N160 100 A protective device is listed within the manufacturer's thermal-magnetic outgoing breaker range. The precise trip characteristics and available adjustments should be confirmed against the supplied device markings.
Identified by ABB order code 1SDX248664R1, the EPX-XT1N-TM1004 belongs to the ABB Protecta Power Devices range. Its combination of compact XT1N construction, four-pole switching and a 36 kA fault-interruption classification makes it a practical solution for professional distribution panelboard installations.
The ABB EPX-XT1N-TM1004 provides thermal-magnetic overcurrent protection for suitably rated electrical distribution circuits. Its compact Tmax XT1N160 construction is particularly useful in compatible Protecta Power panelboards where effective circuit protection must be combined with efficient use of available installation space.
The thermal protection element responds to sustained overload currents. If a circuit carries excessive current for a sufficient period, the thermal mechanism initiates operation of the breaker, helping reduce the risk of excessive conductor heating and damage to connected equipment.
The magnetic protection element responds to short-circuit conditions. When fault current reaches the breaker's magnetic operating threshold, the protective mechanism trips to interrupt the circuit. The precise operating characteristic must be checked against the manufacturer's technical information for the fitted device.
The supplied Protecta Power specification identifies the EPX-XT1N-TM1004 with the TMA thermal-magnetic designation. Because ABB offers different thermal-magnetic release arrangements across the Tmax XT family, installers should confirm whether the supplied breaker has fixed or adjustable settings rather than assuming a particular adjustment range.
The four-pole arrangement allows coordinated switching of three phase conductors and a neutral conductor in suitable electrical systems. Neutral protection, neutral switching requirements and the earthing arrangement must be considered during the design process, particularly when selecting protection for three-phase, four-wire distribution circuits.
The 36 kA breaking-capacity classification is an important consideration when selecting a circuit breaker for installations with substantial prospective fault currents. The actual ultimate and service short-circuit breaking capacities must be verified at the relevant system voltage, and the device must be suitable for the installation's calculated fault level.
The ABB Tmax XT1N160 frame provides a compact mechanical design. ABB identifies a nominal width of 110 mm for four-pole XT1 outgoing devices in its Protecta Power selection information. This supports efficient distribution board planning, although the completed installation must also allow adequate space for cable connections, protective covers and maintenance access.
For integration into ABB Protecta Power distribution assemblies, the correct MCCB mounting arrangement, connection components and protective covers must be selected. The compatibility of the breaker and the panelboard should be verified using the relevant ABB selection and installation documentation.
Electrical designers should also assess conductor current-carrying capacity, terminal suitability, installation temperature, fault protection and coordination with upstream protective devices. The completed assembly must be installed and tested in accordance with the applicable electrical installation requirements.
Combining a 100 A rated current, four-pole construction and established ABB thermal-magnetic protection technology, the EPX-XT1N-TM1004 provides a practical outgoing MCCB solution for commercial, industrial and building services distribution applications.
| Product group | Protecta Power Devices |
|---|---|
| Product model | EPX-XT1N-TM1004 |
| ABB order code | 1SDX248664R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Circuit breaker range | ABB SACE Tmax XT |
| Circuit breaker family | XT1N |
| Frame designation | XT1N160 |
| Frame-current designation | 160 A |
| Rated current | 100 A |
| Number of poles | 4 |
| Pole configuration | Four-pole (4P) |
| Breaking-capacity classification | 36 kA, subject to the manufacturer's applicable operating-voltage conditions |
| Protecta Power trip designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Operating mechanism | Manual |
| Nominal four-pole XT1 device width | 110 mm |
| Circuit breaker standard | IEC 60947-2 |
| Corresponding ABB protective device reference | 1SDA067424R1 |
| Compatible distribution system | ABB Protecta Power |
| Related 80 A four-pole model | EPX-XT1N-TM0804 |
| Related 125 A four-pole model | EPX-XT1N-TM1254 |
| Related 100 A three-pole model | EPX-XT1N-TM1003 |
| Related 100 A XT4N four-pole model | EPX-XT4N-TM1004 |
| Primary application | Outgoing circuit protection in compatible low-voltage distribution assemblies |
The ABB EPX-XT1N-TM1004 is a 100 A four-pole thermal-magnetic MCCB designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies.
The EPX-XT1N-TM1004 has a rated current of 100 A and belongs to the ABB Tmax XT1N160 circuit breaker family, which uses a 160 A frame designation.
The EPX-XT1N-TM1004 has a 36 kA breaking-capacity classification in the ABB Protecta Power range. The applicable breaking capacity must be confirmed at the installation's operating voltage.
Yes. The EPX-XT1N-TM1004 is a four-pole (4P) MCCB suitable for appropriately designed three-phase distribution systems requiring coordinated four-pole switching.
TMA is the thermal-magnetic trip designation included in the supplied Protecta Power product specification. The actual protective settings and whether adjustment is available must be confirmed from the markings and technical documentation of the supplied breaker.
Yes. The circuit breaker uses thermal-magnetic protection, providing a thermal response to sustained overload currents and a magnetic response to short-circuit faults.
The EPX-XT1N-TM1004 is a 100 A four-pole circuit breaker, while the EPX-XT1N-TM1003 is the corresponding 100 A three-pole version. Both belong to the ABB Tmax XT1N Protecta Power outgoing device range.
The EPX-XT1N-TM1004 has a rated current of 100 A, while the EPX-XT1N-TM0804 has a rated current of 80 A. Both are four-pole ABB Tmax XT1N thermal-magnetic MCCB configurations with a 36 kA breaking-capacity classification.
Yes. The EPX-XT1N-TM1004 belongs to the ABB Protecta Power Devices range and is intended for compatible distribution assemblies. The appropriate mounting arrangement, connections and protective covers must be confirmed before installation.
ABB Protecta Power moulded case circuit breakers offer a coordinated approach to low-voltage electrical distribution. The EPX-XT1N-TM1004 combines a 100 A rating, four-pole Tmax XT1N construction and 36 kA breaking-capacity classification, supporting electrical contractors and panel builders in creating dependable, professionally assembled distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.