1SDX248662R1 ABB EPX-XT1N-TM0634 63A 4-Pole 36kA Thermal-Magnetic MCCB Tmax XT1N Protecta Power

1SDX248662R1 ABB EPX-XT1N-TM0634 63A 4-Pole 36kA Thermal-Magnetic MCCB Tmax XT1N Protecta Power

ABB EPX-XT1N-TM0634 is a 63 A four-pole Tmax XT1N160 moulded case circuit breaker with a 36 kA breaking-capacity classification and thermal-magnetic overload and short-circuit protection for compatible ABB Protecta Power low-voltage distribution assemblies.

SKU: 1SDX248662R1Alt SKU: EPX-XT1N-TM0634MPN: 1SDX248662R1
Price
List Price £468.53 ex VAT
Your Price (ex VAT)
£468.53
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £468.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£468.53

ABB EPX-XT1N-TM0634 63A 4-Pole 36kA Thermal-Magnetic MCCB

The ABB EPX-XT1N-TM0634 is a 63 A, four-pole moulded case circuit breaker (MCCB) designed for compatible ABB Protecta Power low-voltage distribution assemblies. Built around the ABB SACE Tmax XT1N160 circuit breaker platform, this device combines a 36 kA breaking-capacity classification with thermal-magnetic protection for commercial and industrial electrical installations.

Featuring a four-pole (4P) configuration, the EPX-XT1N-TM0634 provides coordinated switching of three phase conductors and the neutral in appropriately designed three-phase, four-wire distribution systems. Its 63 A rated current makes it suitable for outgoing feeders, sub-distribution circuits and other applications requiring a compact protective device.

The circuit breaker incorporates thermal-magnetic overcurrent protection, combining a thermal element for sustained overload conditions with a magnetic element for short-circuit faults. ABB identifies this Protecta Power product with the TMA designation, while the corresponding 63 A Tmax XT1N breaker uses a fixed thermal-magnetic trip arrangement. The actual trip characteristics should therefore be confirmed from the supplied device documentation.

Identified by ABB order code 1SDX248662R1, the EPX-XT1N-TM0634 belongs to the ABB Protecta Power Devices range. It offers electrical contractors, consultants and panel builders a manufacturer-specified protective device for compatible low-voltage distribution panelboards.

Key Advantages

  • 63 A rated current: Provides overload and short-circuit protection for appropriately designed distribution circuits.
  • Four-pole construction: Supports coordinated switching in suitable three-phase, four-wire installations.
  • 36 kA breaking-capacity classification: Suitable for distribution applications requiring the specified short-circuit interruption capability.
  • ABB Tmax XT1N technology: Uses ABB's established compact moulded case circuit breaker platform.
  • Thermal-magnetic protection: Combines overload and short-circuit protective functions in one device.
  • Compact XT1 frame: Helps make efficient use of space within compatible distribution assemblies.
  • Protecta Power integration: Designed for the appropriate ABB outgoing MCCB mounting and connection arrangement.
  • Manual switching: Provides a means of operating and resetting the circuit breaker.
  • Manufacturer-matched selection: Supports consistent specification of protective devices within ABB distribution systems.
  • Practical maintenance: Clear model and order-code identification assists with replacement and refurbishment projects.

Key Features

  • ABB EPX-XT1N-TM0634 moulded case circuit breaker.
  • 63 A rated current.
  • Four-pole (4P) configuration.
  • 36 kA Protecta Power breaking-capacity classification.
  • ABB SACE Tmax XT1N160 circuit breaker family.
  • 160 A maximum frame-current designation.
  • Thermal-magnetic overcurrent protection.
  • Thermal response to sustained overload currents.
  • Magnetic response to short-circuit faults.
  • TMA designation in the Protecta Power product description.
  • Fixed thermal-magnetic protection characteristics for the corresponding 63 A XT1N breaker.
  • Manual circuit breaker operating mechanism.
  • Four-pole switching for compatible three-phase distribution arrangements.
  • Compact moulded case construction.
  • Suitable for designated ABB Protecta Power outgoing positions.
  • Part of the ABB Protecta Power Devices product range.

Reliable 63A Circuit Protection with ABB Tmax XT1N Technology

The ABB EPX-XT1N-TM0634 is designed to protect appropriately rated electrical distribution circuits against overload and short-circuit conditions. Its compact Tmax XT1N construction makes it a practical choice for compatible Protecta Power panelboards where dependable circuit protection and efficient use of enclosure space are important.

The thermal protection element responds to sustained overcurrent conditions. When a circuit carries excessive current for a sufficient period, the thermal mechanism initiates operation of the breaker to help protect conductors and connected equipment from overheating.

The magnetic protection element responds to short-circuit conditions, providing rapid interruption when fault current reaches the device's magnetic operating threshold. The precise operating characteristic depends on the supplied breaker configuration and should be checked against ABB's technical data.

The Protecta Power description identifies this device as TMA. However, the corresponding ABB XT1N 63 A circuit breaker uses a fixed thermal-magnetic release. Installers should therefore avoid assuming that adjustable thermal or magnetic settings are provided unless confirmed by the actual product marking and manufacturer's documentation.

The four-pole arrangement enables coordinated switching of the phase conductors and neutral in suitable electrical systems. The neutral pole configuration, neutral protection requirements and earthing arrangement must be checked against the installation design before commissioning.

With a 36 kA breaking-capacity classification, the EPX-XT1N-TM0634 is intended for applications requiring the corresponding level of short-circuit interruption capability. The actual ultimate and service breaking capacities must be verified at the installation's operating voltage, and the selected breaker must be suitable for the prospective fault current.

The ABB Tmax XT1N160 frame provides a compact construction, with the four-pole XT1 device occupying a nominal width of 110 mm. This is useful when planning outgoing device layouts within compatible distribution assemblies, although the complete installation space must also account for connections, covers and cable routing.

For installation in an ABB Protecta Power panelboard, the correct mounting components, outgoing connections and protective covers must be selected for the specific assembly. Compatibility should be confirmed using the relevant ABB Protecta Power selection and installation documentation.

Electrical designers should also verify conductor current-carrying capacity, termination suitability, operating temperature, fault protection and coordination with upstream protective devices. The completed assembly must be installed and tested in accordance with the applicable electrical installation requirements.

By combining a 63 A current rating, four-pole construction and established ABB thermal-magnetic protection technology, the EPX-XT1N-TM0634 provides a practical protective device for commercial and industrial low-voltage distribution applications.

Typical Applications

  • ABB Protecta Power outgoing circuit protection.
  • 63 A three-phase distribution circuits.
  • Three-phase, four-wire electrical installations.
  • Commercial low-voltage distribution panelboards.
  • Industrial electrical distribution assemblies.
  • Office buildings and retail premises.
  • Warehouses and logistics facilities.
  • Building services electrical installations.
  • Suitable machinery and equipment supply circuits.
  • Electrical sub-distribution boards.
  • Distribution board refurbishment and maintenance.
  • Professional electrical panel building projects.
  • Replacement of compatible ABB Tmax XT1N outgoing circuit breakers.

Technical Specifications

Product group Protecta Power Devices
Product model EPX-XT1N-TM0634
ABB order code 1SDX248662R1
Product type Moulded case circuit breaker (MCCB)
Circuit breaker range ABB SACE Tmax XT
Circuit breaker family XT1N
Frame designation XT1N160
Frame-current designation 160 A
Rated current 63 A
Number of poles 4
Pole configuration Four-pole (4P)
Breaking-capacity classification 36 kA, subject to the applicable operating voltage and ABB technical data
Protecta Power trip designation TMA
Protection technology Thermal-magnetic
Corresponding 63 A XT1N trip arrangement Fixed thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Operating mechanism Manual
Four-pole XT1 device width 110 mm
Applicable circuit breaker standard IEC 60947-2
Corresponding ABB XT1N breaker reference 1SDA067422R1
Compatible distribution system ABB Protecta Power
Related 32 A four-pole model EPX-XT1N-TM0324
Related 100 A four-pole model EPX-XT1N-TM1004
Related 63 A three-pole model EPX-XT1N-TM0633
Related 63 A four-pole 50 kA model EPX-XT1S-TM0634
Primary application Outgoing circuit protection in compatible low-voltage distribution assemblies

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0634 used for?

The ABB EPX-XT1N-TM0634 is a 63 A four-pole thermal-magnetic MCCB designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies.

What is the rated current of the EPX-XT1N-TM0634?

The EPX-XT1N-TM0634 has a rated current of 63 A and uses the ABB Tmax XT1N160 circuit breaker platform.

What is the breaking capacity of the EPX-XT1N-TM0634?

The EPX-XT1N-TM0634 has a 36 kA breaking-capacity classification in the ABB Protecta Power range. The applicable breaking capacity must be verified at the installation's operating voltage.

Is the EPX-XT1N-TM0634 a four-pole circuit breaker?

Yes. The EPX-XT1N-TM0634 is a four-pole (4P) MCCB suitable for appropriately designed three-phase distribution systems requiring coordinated four-pole switching.

What does TMA mean on the ABB EPX-XT1N-TM0634?

TMA is the thermal-magnetic protection designation used in the Protecta Power product description. The corresponding 63 A ABB XT1N breaker uses fixed thermal-magnetic protection, so adjustable settings should not be assumed without checking the supplied device documentation.

Does the EPX-XT1N-TM0634 provide overload and short-circuit protection?

Yes. Its thermal-magnetic protection provides a thermal response to sustained overloads and a magnetic response to short-circuit faults, subject to the breaker's specified operating characteristics.

What is the difference between EPX-XT1N-TM0634 and EPX-XT1N-TM0633?

The EPX-XT1N-TM0634 is a 63 A four-pole circuit breaker, while the EPX-XT1N-TM0633 is the corresponding 63 A three-pole version. Both belong to the ABB Tmax XT1N 36 kA Protecta Power range.

What is the difference between EPX-XT1N-TM0634 and EPX-XT1S-TM0634?

The EPX-XT1N-TM0634 has a 36 kA breaking-capacity classification, while the EPX-XT1S-TM0634 is the corresponding 50 kA XT1S version. Both are 63 A four-pole thermal-magnetic MCCBs.

Can the EPX-XT1N-TM0634 be installed in ABB Protecta Power panelboards?

Yes. The EPX-XT1N-TM0634 belongs to the ABB Protecta Power Devices range and is intended for compatible distribution assemblies. The correct mounting arrangement, electrical connections and protective covers must be confirmed before installation.

Trusted by Electrical Contractors and Panel Builders

ABB Protecta Power moulded case circuit breakers provide a coordinated solution for low-voltage electrical distribution. The EPX-XT1N-TM0634 combines a 63 A rating, four-pole Tmax XT1N construction and 36 kA breaking-capacity classification, supporting electrical contractors and panel builders in creating dependable, professionally assembled distribution systems.