ABB EPX-XT1N-TM0634 is a 63 A four-pole Tmax XT1N160 moulded case circuit breaker with a 36 kA breaking-capacity classification and thermal-magnetic overload and short-circuit protection for compatible ABB Protecta Power low-voltage distribution assemblies.
£468.53
The ABB EPX-XT1N-TM0634 is a 63 A, four-pole moulded case circuit breaker (MCCB) designed for compatible ABB Protecta Power low-voltage distribution assemblies. Built around the ABB SACE Tmax XT1N160 circuit breaker platform, this device combines a 36 kA breaking-capacity classification with thermal-magnetic protection for commercial and industrial electrical installations.
Featuring a four-pole (4P) configuration, the EPX-XT1N-TM0634 provides coordinated switching of three phase conductors and the neutral in appropriately designed three-phase, four-wire distribution systems. Its 63 A rated current makes it suitable for outgoing feeders, sub-distribution circuits and other applications requiring a compact protective device.
The circuit breaker incorporates thermal-magnetic overcurrent protection, combining a thermal element for sustained overload conditions with a magnetic element for short-circuit faults. ABB identifies this Protecta Power product with the TMA designation, while the corresponding 63 A Tmax XT1N breaker uses a fixed thermal-magnetic trip arrangement. The actual trip characteristics should therefore be confirmed from the supplied device documentation.
Identified by ABB order code 1SDX248662R1, the EPX-XT1N-TM0634 belongs to the ABB Protecta Power Devices range. It offers electrical contractors, consultants and panel builders a manufacturer-specified protective device for compatible low-voltage distribution panelboards.
The ABB EPX-XT1N-TM0634 is designed to protect appropriately rated electrical distribution circuits against overload and short-circuit conditions. Its compact Tmax XT1N construction makes it a practical choice for compatible Protecta Power panelboards where dependable circuit protection and efficient use of enclosure space are important.
The thermal protection element responds to sustained overcurrent conditions. When a circuit carries excessive current for a sufficient period, the thermal mechanism initiates operation of the breaker to help protect conductors and connected equipment from overheating.
The magnetic protection element responds to short-circuit conditions, providing rapid interruption when fault current reaches the device's magnetic operating threshold. The precise operating characteristic depends on the supplied breaker configuration and should be checked against ABB's technical data.
The Protecta Power description identifies this device as TMA. However, the corresponding ABB XT1N 63 A circuit breaker uses a fixed thermal-magnetic release. Installers should therefore avoid assuming that adjustable thermal or magnetic settings are provided unless confirmed by the actual product marking and manufacturer's documentation.
The four-pole arrangement enables coordinated switching of the phase conductors and neutral in suitable electrical systems. The neutral pole configuration, neutral protection requirements and earthing arrangement must be checked against the installation design before commissioning.
With a 36 kA breaking-capacity classification, the EPX-XT1N-TM0634 is intended for applications requiring the corresponding level of short-circuit interruption capability. The actual ultimate and service breaking capacities must be verified at the installation's operating voltage, and the selected breaker must be suitable for the prospective fault current.
The ABB Tmax XT1N160 frame provides a compact construction, with the four-pole XT1 device occupying a nominal width of 110 mm. This is useful when planning outgoing device layouts within compatible distribution assemblies, although the complete installation space must also account for connections, covers and cable routing.
For installation in an ABB Protecta Power panelboard, the correct mounting components, outgoing connections and protective covers must be selected for the specific assembly. Compatibility should be confirmed using the relevant ABB Protecta Power selection and installation documentation.
Electrical designers should also verify conductor current-carrying capacity, termination suitability, operating temperature, fault protection and coordination with upstream protective devices. The completed assembly must be installed and tested in accordance with the applicable electrical installation requirements.
By combining a 63 A current rating, four-pole construction and established ABB thermal-magnetic protection technology, the EPX-XT1N-TM0634 provides a practical protective device for commercial and industrial low-voltage distribution applications.
| Product group | Protecta Power Devices |
|---|---|
| Product model | EPX-XT1N-TM0634 |
| ABB order code | 1SDX248662R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Circuit breaker range | ABB SACE Tmax XT |
| Circuit breaker family | XT1N |
| Frame designation | XT1N160 |
| Frame-current designation | 160 A |
| Rated current | 63 A |
| Number of poles | 4 |
| Pole configuration | Four-pole (4P) |
| Breaking-capacity classification | 36 kA, subject to the applicable operating voltage and ABB technical data |
| Protecta Power trip designation | TMA |
| Protection technology | Thermal-magnetic |
| Corresponding 63 A XT1N trip arrangement | Fixed thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Operating mechanism | Manual |
| Four-pole XT1 device width | 110 mm |
| Applicable circuit breaker standard | IEC 60947-2 |
| Corresponding ABB XT1N breaker reference | 1SDA067422R1 |
| Compatible distribution system | ABB Protecta Power |
| Related 32 A four-pole model | EPX-XT1N-TM0324 |
| Related 100 A four-pole model | EPX-XT1N-TM1004 |
| Related 63 A three-pole model | EPX-XT1N-TM0633 |
| Related 63 A four-pole 50 kA model | EPX-XT1S-TM0634 |
| Primary application | Outgoing circuit protection in compatible low-voltage distribution assemblies |
The ABB EPX-XT1N-TM0634 is a 63 A four-pole thermal-magnetic MCCB designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies.
The EPX-XT1N-TM0634 has a rated current of 63 A and uses the ABB Tmax XT1N160 circuit breaker platform.
The EPX-XT1N-TM0634 has a 36 kA breaking-capacity classification in the ABB Protecta Power range. The applicable breaking capacity must be verified at the installation's operating voltage.
Yes. The EPX-XT1N-TM0634 is a four-pole (4P) MCCB suitable for appropriately designed three-phase distribution systems requiring coordinated four-pole switching.
TMA is the thermal-magnetic protection designation used in the Protecta Power product description. The corresponding 63 A ABB XT1N breaker uses fixed thermal-magnetic protection, so adjustable settings should not be assumed without checking the supplied device documentation.
Yes. Its thermal-magnetic protection provides a thermal response to sustained overloads and a magnetic response to short-circuit faults, subject to the breaker's specified operating characteristics.
The EPX-XT1N-TM0634 is a 63 A four-pole circuit breaker, while the EPX-XT1N-TM0633 is the corresponding 63 A three-pole version. Both belong to the ABB Tmax XT1N 36 kA Protecta Power range.
The EPX-XT1N-TM0634 has a 36 kA breaking-capacity classification, while the EPX-XT1S-TM0634 is the corresponding 50 kA XT1S version. Both are 63 A four-pole thermal-magnetic MCCBs.
Yes. The EPX-XT1N-TM0634 belongs to the ABB Protecta Power Devices range and is intended for compatible distribution assemblies. The correct mounting arrangement, electrical connections and protective covers must be confirmed before installation.
ABB Protecta Power moulded case circuit breakers provide a coordinated solution for low-voltage electrical distribution. The EPX-XT1N-TM0634 combines a 63 A rating, four-pole Tmax XT1N construction and 36 kA breaking-capacity classification, supporting electrical contractors and panel builders in creating dependable, professionally assembled distribution systems.