1SDX248661R1 ABB EPX-XT1N-TM0324 32A 4P 36kA TMA Moulded Case Circuit Breaker

1SDX248661R1 ABB EPX-XT1N-TM0324 32A 4P 36kA TMA Moulded Case Circuit Breaker

ABB EPX-XT1N-TM0324 (1SDX248661R1) is a 32 A four-pole SACE Tmax XT1N moulded case circuit breaker with a specified 36 kA short-circuit breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power electrical distribution systems.

SKU: 1SDX248661R1Alt SKU: EPX-XT1N-TM0324MPN: 1SDX248661R1
Price
List Price £468.53 ex VAT
Your Price (ex VAT)
£468.53
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £468.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£468.53

Why Choose the ABB EPX-XT1N-TM0324 32A 4-Pole Moulded Case Circuit Breaker?

The ABB EPX-XT1N-TM0324 is a compact and reliable 32 A four-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT1N160 circuit breaker platform, this protective device combines dependable circuit protection with a space-efficient design for commercial and industrial electrical installations.

As part of the ABB Protecta Power Devices product group, the EPX-XT1N-TM0324 is configured for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip unit provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The four-pole construction supports coordinated switching of three phase conductors and a neutral conductor in suitable electrical installations.

With a rated current of 32 A, a specified 36 kA short-circuit breaking capacity and a four-pole (4P) configuration, the EPX-XT1N-TM0324 is suitable for outgoing feeder protection in three-phase distribution systems. Its compact 110 mm nominal device width supports efficient use of distribution board space, making it a practical solution for electrical contractors, panel builders, switchboard manufacturers and building services engineers.

Key Advantages

  • Reliable 32 A moulded case circuit breaker for commercial and industrial low-voltage power distribution.
  • 36 kA short-circuit breaking capacity in the specified ABB Protecta Power configuration.
  • Four-pole (4P) construction for coordinated switching of three phase conductors and a neutral conductor.
  • Thermal-magnetic adjustable (TMA) protection against overload and short-circuit conditions.
  • Based on the established ABB SACE Tmax XT1N160 circuit breaker platform.
  • Compact 110 mm nominal width helps conserve valuable distribution board space.
  • Designed for integration into ABB Protecta Power distribution boards.
  • Adjustable protection characteristics support coordination with connected cables and electrical equipment.
  • Robust moulded case construction provides dependable circuit protection in demanding electrical environments.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT1N-TM0324 product designation.
  • ABB order code 1SDX248661R1.
  • ABB SACE Tmax XT1N160 circuit breaker platform.
  • 32 A rated current for outgoing circuit protection.
  • 160 A frame rating within the XT1N160 platform.
  • 36 kA breaking capacity in the specified Protecta Power application.
  • Four-pole (4P) configuration for three-phase distribution systems incorporating a neutral conductor.
  • Thermal-magnetic adjustable (TMA) trip unit for overload and short-circuit protection.
  • Thermal overload protection responds to sustained excessive current.
  • Magnetic short-circuit protection provides rapid fault interruption.
  • 110 mm nominal device width for compact distribution board installations.
  • Manual operating mechanism for circuit switching and isolation when correctly installed.
  • Designed for installation using compatible ABB Protecta Power mounting and connection accessories.
  • Suitable for commercial, industrial and building services electrical distribution systems.

Reliable Four-Pole Circuit Protection for Electrical Distribution Systems

Moulded case circuit breakers such as the ABB EPX-XT1N-TM0324 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained overcurrent, while the magnetic protection element operates rapidly during short-circuit faults. This combined protection helps reduce the risk of cable damage, electrical equipment failure and disruption to power distribution infrastructure.

The ABB SACE Tmax XT1N160 platform provides dependable low-voltage circuit protection in a compact moulded case design. Its four-pole configuration enables coordinated switching of three phase conductors and a neutral conductor, making the EPX-XT1N-TM0324 suitable for three-phase distribution systems where neutral switching is required. The thermal-magnetic adjustable trip unit supports appropriate protection coordination with connected cables, electrical loads and downstream protective devices.

The 32 A rated current makes this breaker suitable for appropriately designed outgoing feeders and electrical circuits, while its 36 kA specified breaking capacity provides short-circuit protection for compatible distribution applications. The 110 mm nominal width helps optimise available space within electrical distribution boards, making the device suitable for new installations and upgrades to existing ABB Protecta Power assemblies.

Correct circuit breaker selection should consider the installation operating voltage, prospective short-circuit current, conductor sizing, neutral arrangement and protective device coordination. The applicable breaking capacity, thermal-magnetic adjustment settings and mounting accessories should be assessed against the complete electrical installation design and relevant ABB technical documentation.

Typical Applications

  • ABB Protecta Power low-voltage electrical distribution boards.
  • Four-pole outgoing feeder protection in commercial buildings.
  • Three-phase and neutral electrical distribution circuits.
  • Industrial electrical distribution panels and manufacturing facilities.
  • Commercial building main and sub-distribution installations.
  • Electrical distribution for offices, retail premises and public buildings.
  • Building services infrastructure and mechanical plant electrical supplies.
  • Electrical switchboard manufacturing and distribution board assembly.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT
Circuit breaker platform XT1N160
ABB order code 1SDX248661R1
Product type Moulded case circuit breaker (MCCB)
Rated current 32 A
Frame rating 160 A
Breaking capacity 36 kA (specified Protecta Power application)
Number of poles 4
Pole configuration Four-pole (4P)
Trip unit Thermal-magnetic adjustable (TMA)
Trip technology Thermal-magnetic
Thermal protection Overload protection
Magnetic protection Short-circuit protection
Protection functions Overload and short-circuit protection
Applicable standard IEC 60947-2
Nominal device width 110 mm
Mounting type Compatible ABB Protecta Power distribution assembly
Installation Fixed distribution board installation using compatible mounting and connection accessories
Application Three-phase low-voltage electrical power distribution

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0324 used for?

The ABB EPX-XT1N-TM0324 is a 32 A four-pole moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.

What is the rated current and breaking capacity of this circuit breaker?

The EPX-XT1N-TM0324 has a 32 A rated current and a specified 36 kA short-circuit breaking capacity within the ABB Protecta Power range. It is based on the ABB XT1N160 platform, which has a 160 A frame rating. The applicable breaking capacity must be assessed against the installation voltage and prospective fault current.

What does TMA mean on the ABB EPX-XT1N-TM0324?

TMA stands for Thermal-Magnetic Adjustable. This protection technology combines a thermal element for sustained overload conditions with a magnetic element for short-circuit faults. Adjustable trip characteristics support coordination with electrical cables and connected equipment. Exact adjustment ranges depend on the specific ABB XT1N160 trip unit configuration.

What is the advantage of the four-pole configuration?

The four-pole (4P) configuration enables coordinated switching of three phase conductors and a neutral conductor. This makes the EPX-XT1N-TM0324 suitable for three-phase electrical distribution systems where neutral switching is required. The neutral protection arrangement must be selected in accordance with the electrical installation design and applicable regulations.

Where is the ABB EPX-XT1N-TM0324 typically installed?

The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. The ABB XT1N four-pole platform has a nominal width of 110 mm, making it suitable for compact electrical distribution assemblies. Compatible mounting and connection accessories should be selected for the installation.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT1N-TM0324 combines 32 A circuit protection, four-pole switching, 36 kA specified short-circuit breaking capacity and thermal-magnetic adjustable functionality to support reliable electrical installations in commercial and industrial ABB Protecta Power distribution systems.