Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT1S-TM1603 (1SDX248658R1) is a 160 A three-pole SACE Tmax XT1S moulded case circuit breaker with a specified 50 kA short-circuit breaking capacity and thermal-magnetic adjustable protection for compatible ABB Protecta Power electrical distribution systems.
£609.26
The ABB EPX-XT1S-TM1603 is a compact, high-performance 160 A three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB SACE Tmax XT1S160 circuit breaker platform, this protective device combines robust electrical protection with a space-efficient design for commercial and industrial power distribution installations.
As part of the ABB Protecta Power Devices product group, the EPX-XT1S-TM1603 is configured for integration into compatible ABB Protecta Power distribution assemblies. Its thermal-magnetic adjustable (TMA) trip unit provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The three-pole construction enables simultaneous switching and protection of all three phase conductors in suitable electrical installations.
With a rated current of 160 A, a specified 50 kA short-circuit breaking capacity and a three-pole (3P) configuration, the EPX-XT1S-TM1603 is suitable for outgoing feeder protection and three-phase electrical distribution circuits. Its compact 80 mm nominal width makes it particularly useful where distribution board space is limited, providing a practical solution for electrical contractors, switchboard manufacturers, panel builders and facilities engineers.
Moulded case circuit breakers such as the ABB EPX-XT1S-TM1603 protect electrical distribution systems by automatically interrupting current when overload or short-circuit conditions occur. The thermal protection element responds to sustained overcurrent, while the magnetic protection element operates rapidly during short-circuit faults. This combined protection helps reduce the risk of cable damage, equipment failure and disruption to electrical distribution infrastructure.
The ABB SACE Tmax XT1S160 platform is designed to provide dependable low-voltage circuit protection in a compact format. Its three-pole configuration enables coordinated switching and protection of all three phase conductors, making the EPX-XT1S-TM1603 suitable for three-phase outgoing feeders and distribution circuits. The thermal-magnetic adjustable trip unit supports appropriate protection coordination with connected cables, electrical loads and downstream protective devices.
The 160 A rated current and 50 kA specified breaking capacity make this breaker suitable for appropriately designed commercial and industrial distribution installations. Its 80 mm nominal width helps conserve valuable panel space while maintaining robust circuit protection. The ABB Protecta Power configuration supports integration into compatible distribution assemblies, simplifying the selection of protective devices for new installations and distribution board upgrades.
Final breaker selection should consider the prospective short-circuit current, system operating voltage, conductor sizing, protective device coordination and installation requirements. The applicable breaking capacity and thermal-magnetic trip settings should be verified against the complete electrical distribution design and relevant ABB technical documentation.
| Product group | Protecta Power Devices |
|---|---|
| Series | SACE Tmax XT |
| Circuit breaker platform | XT1S160 |
| ABB order code | 1SDX248658R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 160 A |
| Frame rating | 160 A |
| Breaking capacity | 50 kA (specified Protecta Power application) |
| Number of poles | 3 |
| Pole configuration | Three-pole (3P) |
| Trip unit | Thermal-magnetic adjustable (TMA) |
| Trip technology | Thermal-magnetic |
| Thermal protection | Overload protection |
| Magnetic protection | Short-circuit protection |
| Protection functions | Overload and short-circuit protection |
| Applicable standard | IEC 60947-2 |
| Nominal device width | 80 mm |
| Mounting type | Compatible ABB Protecta Power distribution assembly |
| Installation | Fixed distribution board installation using compatible mounting and connection accessories |
| Application | Three-phase low-voltage electrical power distribution |
The ABB EPX-XT1S-TM1603 is a 160 A three-pole moulded case circuit breaker designed to protect three-phase electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.
The EPX-XT1S-TM1603 has a 160 A rated current and a specified 50 kA short-circuit breaking capacity within the ABB Protecta Power range. The applicable breaking capacity must be assessed against the installation operating voltage and prospective fault current.
TMA stands for Thermal-Magnetic Adjustable. This trip technology combines thermal protection against sustained overload currents with magnetic protection against short-circuit faults. The adjustable characteristics support protection coordination with electrical cables and connected equipment. Exact adjustment ranges should be checked against the specific ABB XT1S160 trip unit configuration.
The three-pole (3P) configuration enables the circuit breaker to protect and switch three phase conductors simultaneously. This makes it suitable for three-phase distribution circuits and appropriately designed three-phase equipment supplies. Unlike a four-pole breaker, the three-pole EPX-XT1S-TM1603 does not provide a dedicated switched neutral pole.
The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides protection for three-phase outgoing circuits. The ABB XT1S three-pole platform has a nominal width of 80 mm, making it suitable for compact distribution assemblies. Compatible mounting and connection accessories should be selected for the installation.
ABB SACE Tmax XT circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT1S-TM1603 combines 160 A current capacity, three-pole switching, 50 kA specified short-circuit protection and thermal-magnetic adjustable functionality to support reliable electrical installations in commercial and industrial ABB Protecta Power distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.