1SDX248657R1 ABB EPX-XT1S-TM0633 Protecta Power 63A 3-Pole 50kA MCCB with TMA Thermal-Magnetic Trip

1SDX248657R1 ABB EPX-XT1S-TM0633 Protecta Power 63A 3-Pole 50kA MCCB with TMA Thermal-Magnetic Trip

ABB EPX-XT1S-TM0633 Protecta Power 63 A three-pole 50 kA moulded case circuit breaker with thermal-magnetic protection, based on the ABB SACE Tmax XT1S platform, order code 1SDX248657R1, for compatible low-voltage electrical distribution installations.

SKU: 1SDX248657R1Alt SKU: EPX-XT1S-TM0633MPN: 1SDX248657R1
Price
List Price £394.63 ex VAT
Your Price (ex VAT)
£394.63
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £394.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£394.63

Why Choose the ABB EPX-XT1S-TM0633 63A 3-Pole 50kA MCCB?

The ABB EPX-XT1S-TM0633 is a 63 A three-pole moulded case circuit breaker (MCCB) designed for circuit protection within compatible ABB Protecta Power low-voltage electrical distribution assemblies. Based on the ABB SACE Tmax XT1S circuit breaker platform, this device combines a 50 kA specified breaking capacity with thermal-magnetic protection to help safeguard appropriately designed three-phase circuits against overloads and short circuits.

Part of the ABB Protecta Power Devices product group, the EPX-XT1S-TM0633 is identified by ABB order code 1SDX248657R1. Its manufacturer product description is EPX-XT1S-TM0633 63A 3P 50kA MCCB - TMA. The product is intended for installations requiring a manufacturer-specified 63 A outgoing protective device with three-pole switching and a high short-circuit breaking capacity.

The ABB SACE Tmax XT1S platform forms part of the wider Tmax XT family of low-voltage circuit breakers. The 63 A rated current identifies the nominal current of this particular device, while its three-pole configuration allows coordinated switching and protection of three phase conductors. Its specified 50 kA breaking capacity makes it relevant to distribution systems where the prospective fault current requires an appropriately rated circuit breaker.

ABB's Protecta Power selection information identifies the XT1S three-pole outgoing MCCB range with a nominal device width of 80 mm. This compact arrangement supports efficient use of compatible distribution panelboard space while retaining the circuit protection characteristics associated with the XT1S platform.

Key Advantages

  • 63 A rated current for appropriately designed three-phase outgoing circuits.
  • Three-pole (3P) configuration for coordinated switching and protection of three phase conductors.
  • 50 kA specified breaking capacity for applications requiring substantial short-circuit interruption capability.
  • Based on the established ABB SACE Tmax XT1S moulded case circuit breaker platform.
  • Thermal-magnetic protection against sustained overloads and short-circuit faults.
  • TMA designation in the manufacturer product description.
  • Designed for compatible ABB Protecta Power electrical distribution assemblies.
  • 80 mm nominal width identified for the XT1S three-pole outgoing device range.
  • Combines a 63 A circuit rating with the XT1S 50 kA breaking-capacity class.
  • Suitable for commercial and industrial low-voltage distribution applications.
  • Supports protection coordination when correctly selected alongside upstream and downstream devices.
  • Provides a thermal-magnetic MCCB option without requiring an electronic trip unit.
  • Part of ABB's coordinated range of Protecta Power outgoing circuit breakers.
  • Related XT1S variants are available with alternative current ratings and pole configurations.
  • Clearly identified by ABB order code 1SDX248657R1 for accurate specification and procurement.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT1S-TM0633 manufacturer model reference.
  • 63 A nominal rated current.
  • Three-pole (3P) circuit breaker configuration.
  • 50 kA specified breaking capacity.
  • ABB SACE Tmax XT1S circuit breaker platform.
  • XT1 frame family.
  • S breaking-capacity performance class.
  • Thermal-magnetic trip technology.
  • TMA manufacturer trip designation.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit fault conditions.
  • Common three-pole switching arrangement.
  • 80 mm nominal width for the XT1S three-pole outgoing range.
  • Designed for low-voltage electrical distribution applications.
  • Suitable for compatible ABB Protecta Power outgoing MCCB positions.
  • Requires appropriately selected mounting, connection and protective-cover arrangements.
  • Available alongside related 32 A, 80 A, 100 A and 160 A XT1S devices.
  • Separate four-pole XT1S configuration available for applications requiring four-pole switching.
  • ABB order code 1SDX248657R1.

63A Thermal-Magnetic Protection with 50kA Breaking Capacity

The ABB EPX-XT1S-TM0633 provides circuit protection using a thermal-magnetic trip arrangement. Thermal-magnetic MCCBs employ complementary operating principles to respond to sustained overloads and short-circuit faults. When correctly specified and installed, these functions help protect electrical conductors and connected equipment against the effects of excessive current.

The thermal protection element responds to overload conditions in which current exceeds the applicable operating threshold for a sufficient period. Its time-dependent operating characteristic allows the circuit breaker to respond to sustained overloads while accommodating normal short-duration current variations within the device's specified operating limits.

The magnetic protection element responds to substantially higher fault currents associated with short circuits. Rapid fault interruption is particularly important because high short-circuit currents can produce significant thermal and mechanical stresses within distribution equipment, conductors and electrical connections.

The EPX-XT1S-TM0633 is specified as a 50 kA MCCB. This breaking-capacity figure must be assessed against the operating voltage and the prospective short-circuit current at the installation point. The relevant ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics) should be confirmed from the applicable ABB technical documentation.

The manufacturer's TMA designation identifies the specified thermal-magnetic protection arrangement. The exact trip characteristics and any available adjustment facilities must be verified against the supplied device documentation before commissioning. The required protection settings and coordination should be determined from the electrical design rather than inferred solely from the nominal 63 A current rating.

Three-Pole Protection for Commercial and Industrial Distribution

The three-pole configuration allows the EPX-XT1S-TM0633 to provide coordinated switching and protection of three phase conductors within a suitable three-phase electrical system. This makes the device relevant to distribution circuits supplying three-phase equipment, downstream distribution assemblies and other appropriately designed electrical loads.

The 63 A rated current and 50 kA breaking capacity describe different aspects of the circuit breaker's performance. Rated current relates to its nominal current-carrying and overload protection characteristics, while breaking capacity relates to its ability to interrupt short-circuit current under specified conditions.

A 63 A outgoing circuit may therefore require a 50 kA circuit breaker when supplied from an electrical distribution system with a sufficiently high prospective fault level. Conversely, the presence of a 50 kA breaking-capacity rating does not permit the device to protect a circuit whose normal operating current exceeds its appropriately applied current rating.

The EPX-XT1S-TM0633 is a three-pole device and should not be treated as a four-pole circuit breaker. Where the electrical design requires four-pole switching, ABB lists the separately specified EPX-XT1S-TM0634. The correct pole configuration must be selected according to the distribution system and applicable installation requirements.

Compact ABB Tmax XT1S Circuit Breaker Platform

The ABB SACE Tmax XT1S platform forms part of the wider Tmax XT moulded case circuit breaker range. The XT1 frame family provides a compact protective-device format for low-voltage distribution applications requiring suitable current ratings and short-circuit protection.

ABB's Protecta Power selection information identifies the XT1S three-pole outgoing range with a nominal width of 80 mm. This dimension relates to the device range identified in the selection guide and can assist with planning compatible outgoing MCCB arrangements.

The nominal device width must not be interpreted as the complete installed dimensions of the circuit breaker, mounting components, cable terminals and protective covers. Final layout requirements must be checked against the relevant ABB panelboard drawings and installation instructions.

The XT1S frame family includes devices with nominal currents up to 160 A, but the EPX-XT1S-TM0633 itself is rated at 63 A. The frame family does not alter the current rating of this particular protective device. Cable sizing and circuit protection must therefore be based on the specified 63 A device and its actual operating characteristics.

Protecta Power Installation and Compatibility

The ABB Protecta Power system provides a coordinated range of low-voltage electrical distribution assemblies, protective devices and installation accessories. The EPX-XT1S-TM0633 is intended for use in compatible outgoing MCCB positions, subject to the specific panelboard configuration and approved connection arrangements.

Correct installation requires confirmation of the mechanical mounting arrangement, electrical connections, protective covering and available cable termination space. The circuit breaker must be installed using components suitable for the relevant Protecta Power assembly and in accordance with ABB's applicable installation instructions.

The required cable size must be determined from the electrical design. Important considerations include conductor material, current-carrying capacity, installation method, ambient temperature, grouping factors, voltage drop, short-circuit withstand requirements and the compatibility of the selected terminals.

The appropriate MCCB mounting, connection and cover accessories must be selected for the intended installation. The exact scope of supply associated with ABB order code 1SDX248657R1 should be confirmed before ordering. A complete panelboard, mounting kit or unrelated connection accessories should not be assumed to be included unless expressly specified.

Installation, inspection and commissioning should be carried out by suitably competent personnel in accordance with the manufacturer's instructions and applicable electrical installation standards. The final protection settings and coordination requirements should be established from the approved electrical design.

XT1S 50kA vs XT1N 36kA: Choosing the Correct MCCB

ABB offers the EPX-XT1S-TM0633 alongside the related EPX-XT1N-TM0633. Both products are 63 A three-pole thermal-magnetic XT1 MCCBs, but they have different specified short-circuit breaking capacities.

The EPX-XT1S-TM0633 is specified at 50 kA, while the EPX-XT1N-TM0633 is specified at 36 kA. The correct performance class must be selected according to the prospective short-circuit current, operating voltage and the applicable circuit protection requirements.

A higher breaking capacity does not increase the device's nominal current rating. Both products remain 63 A circuit breakers, and the suitability of either variant depends on the electrical system design, conductor protection and protective-device coordination.

ABB also provides related XT1S options, including the EPX-XT1S-TM0323 rated at 32 A and the EPX-XT1S-TM1603 rated at 160 A. Where a four-pole arrangement is required, the EPX-XT1S-TM0634 provides a separately specified 63 A option. These variants should not be substituted without checking their electrical and mechanical suitability.

Typical Applications

  • ABB Protecta Power outgoing circuit protection installations.
  • 63 A three-phase electrical distribution circuits.
  • Commercial building low-voltage distribution panelboards.
  • Industrial electrical distribution assemblies.
  • Three-phase plant and equipment supply circuits.
  • Electrical switchrooms and building services distribution installations.
  • Submain circuits supplying appropriately rated downstream equipment.
  • Circuits requiring thermal-magnetic overload and short-circuit protection.
  • Installations requiring a suitably rated 50 kA outgoing MCCB.
  • Distribution systems with relatively modest outgoing circuit currents and higher prospective fault levels.
  • Switchboard manufacturing and electrical panel-building projects.
  • Compatible Protecta Power panelboard extensions and circuit additions.
  • Replacement of a correctly matched ABB Protecta Power XT1S protective device.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power
ABB order code 1SDX248657R1
Manufacturer product description EPX-XT1S-TM0633 63A 3P 50kA MCCB - TMA
Product type Moulded case circuit breaker
Product category Low-voltage circuit protection devices
Circuit breaker family ABB SACE Tmax XT
Device platform XT1S
Frame family XT1
Nominal frame family size 160 A
Breaking-capacity class S
Rated current 63 A
Number of poles 3
Pole configuration 3P
Specified breaking capacity 50 kA
Protection technology Thermal-magnetic
Manufacturer trip designation TMA
Protection functions Overload and short-circuit protection
Nominal width listed for XT1S three-pole outgoing devices 80 mm
Primary application Three-phase low-voltage circuit protection
Associated distribution system ABB Protecta Power
Typical installation position Compatible outgoing MCCB arrangement
Operating voltage Confirm from the applicable ABB technical documentation
Applicable Icu and Ics ratings Verify at the intended operating voltage
Thermal and magnetic trip characteristics Confirm for the supplied device
Terminal configuration Confirm against the supplied MCCB and connection accessories
Maximum conductor capacity Dependent on the selected terminal arrangement
Mounting and protective-cover accessories Select according to the Protecta Power assembly
Related 63 A 36 kA variant EPX-XT1N-TM0633
Related 32 A 50 kA variant EPX-XT1S-TM0323
Related 63 A four-pole variant EPX-XT1S-TM0634
Related 160 A 50 kA variant EPX-XT1S-TM1603

Frequently Asked Questions

What is the ABB EPX-XT1S-TM0633 used for?

The ABB EPX-XT1S-TM0633 is a 63 A three-pole moulded case circuit breaker designed for compatible ABB Protecta Power low-voltage distribution installations. It provides thermal-magnetic overload and short-circuit protection for appropriately designed three-phase electrical circuits.

What is the breaking capacity of the ABB EPX-XT1S-TM0633?

The EPX-XT1S-TM0633 has a manufacturer-specified 50 kA breaking capacity. The applicable interruption rating must be verified at the intended operating voltage using ABB's technical documentation, together with the prospective short-circuit current at the installation point.

What does TMA mean on the ABB EPX-XT1S-TM0633?

TMA identifies the manufacturer's thermal-magnetic trip arrangement. The thermal element provides overload protection, while the magnetic element provides short-circuit protection. The exact trip characteristics and any available adjustment facilities must be confirmed from the documentation for the supplied device.

What is the difference between EPX-XT1S-TM0633 and EPX-XT1N-TM0633?

Both products are 63 A three-pole thermal-magnetic XT1 MCCBs. The EPX-XT1S-TM0633 has a specified breaking capacity of 50 kA, while the EPX-XT1N-TM0633 is specified at 36 kA. The correct version depends on the prospective fault current, operating voltage and electrical protection design.

What is the ABB order code for the EPX-XT1S-TM0633?

The ABB order code is 1SDX248657R1, and the model reference is EPX-XT1S-TM0633. The manufacturer product description is EPX-XT1S-TM0633 63A 3P 50kA MCCB - TMA, within the ABB Protecta Power Devices product group.

Trusted ABB Protecta Power Circuit Protection Solutions

ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage protective devices, panelboards and installation accessories. The EPX-XT1S-TM0633 combines a 63 A three-pole ABB SACE Tmax XT1S circuit breaker with 50 kA specified breaking capacity and thermal-magnetic protection, supporting outgoing circuit protection within compatible Protecta Power electrical distribution assemblies.