1SDX248656R1 ABB EPX-XT1S-TM0323 Protecta Power 32A 3-Pole 50kA MCCB with TMA Thermal-Magnetic Trip

1SDX248656R1 ABB EPX-XT1S-TM0323 Protecta Power 32A 3-Pole 50kA MCCB with TMA Thermal-Magnetic Trip

ABB EPX-XT1S-TM0323 Protecta Power 32 A three-pole 50 kA moulded case circuit breaker with thermal-magnetic TMA protection, based on the ABB SACE Tmax XT1S platform, order code 1SDX248656R1, for compatible low-voltage electrical distribution installations.

SKU: 1SDX248656R1Alt SKU: EPX-XT1S-TM0323MPN: 1SDX248656R1
Price
List Price £394.63 ex VAT
Your Price (ex VAT)
£394.63
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £394.63
Trade pricing is personalised to your account

Manufacturer Lead Time

£394.63

Why Choose the ABB EPX-XT1S-TM0323 32A 3-Pole MCCB?

The ABB EPX-XT1S-TM0323 is a 32 A three-pole moulded case circuit breaker (MCCB) designed for outgoing circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies. Based on the ABB SACE Tmax XT1S circuit breaker platform, the device combines a 50 kA specified breaking capacity with thermal-magnetic TMA protection for appropriately designed three-phase electrical circuits.

Part of the ABB Protecta Power Devices product group, the EPX-XT1S-TM0323 is identified by ABB order code 1SDX248656R1. Its manufacturer product description is EPX-XT1S-TM0323 32A 3P 50kA MCCB - TMA. This combination of a 32 A current rating, three-pole configuration and 50 kA breaking capacity makes it a suitable candidate for distribution applications where a relatively low-rated outgoing circuit requires substantial short-circuit interruption capability.

The XT1S platform belongs to ABB's SACE Tmax XT family of moulded case circuit breakers. The 32 A rating identifies the nominal current of this protective device, while its three-pole configuration provides coordinated switching and protection of three phase conductors. ABB's Protecta Power selection information identifies the XT1S three-pole outgoing range as occupying a nominal 80 mm device width, supporting compact arrangements in compatible distribution panelboards.

Key Advantages

  • 32 A rated current for appropriately designed three-phase outgoing circuits.
  • Three-pole (3P) configuration for coordinated switching and protection of three phase conductors.
  • 50 kA specified breaking capacity for installations requiring suitably rated fault interruption.
  • Uses the established ABB SACE Tmax XT1S moulded case circuit breaker platform.
  • Thermal-magnetic TMA protection against overload and short-circuit conditions.
  • Suitable for compatible ABB Protecta Power electrical distribution assemblies.
  • 80 mm nominal device width identified for the XT1S three-pole outgoing range.
  • Combines a relatively low current rating with the XT1S 50 kA breaking-capacity class.
  • Supports the protection of appropriately rated three-phase circuits in commercial and industrial installations.
  • Provides a thermal-magnetic alternative to electronic-trip MCCBs where electronic protection functions are not required.
  • Forms part of ABB's coordinated range of Protecta Power outgoing protective devices.
  • Available alongside related XT1S devices with alternative current ratings and pole configurations.
  • Clearly identified by ABB order code 1SDX248656R1 for accurate specification and procurement.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT1S-TM0323 manufacturer model reference.
  • 32 A nominal rated current.
  • Three-pole (3P) circuit breaker configuration.
  • 50 kA specified breaking capacity.
  • ABB SACE Tmax XT1S circuit breaker platform.
  • XT1 frame family.
  • S breaking-capacity performance class.
  • Thermal-magnetic protection technology.
  • TMA trip-unit designation.
  • Thermal response to sustained overload conditions.
  • Magnetic response to short-circuit fault conditions.
  • Common three-pole switching arrangement.
  • 80 mm nominal width for the XT1S three-pole outgoing device range.
  • Designed for low-voltage electrical distribution applications.
  • Suitable for compatible ABB Protecta Power outgoing MCCB installations.
  • Requires appropriately selected mounting, connection and protective-cover arrangements for the completed installation.
  • Related XT1S variants available for other current ratings.
  • Manufacturer order code 1SDX248656R1.

32A Thermal-Magnetic Protection with 50kA Breaking Capacity

The ABB EPX-XT1S-TM0323 provides three-pole circuit protection through a thermal-magnetic TMA trip arrangement. Thermal-magnetic circuit breakers use complementary operating principles to respond to overload and short-circuit conditions, helping protect electrical conductors and connected equipment when correctly selected and installed.

The thermal protection element responds to sustained overcurrent conditions. Where a circuit carries current above the applicable protection threshold for a sufficient period, the thermal mechanism provides an overload response. This time-dependent behaviour is intended to distinguish sustained overloads from normal short-duration variations in current.

The magnetic protection element responds to the substantially higher currents associated with short-circuit faults. Rapid interruption of high fault currents is important because short circuits can produce significant thermal and mechanical stresses within electrical distribution equipment.

The EPX-XT1S-TM0323 is specified as a 50 kA MCCB. Its breaking capacity must be considered alongside the system operating voltage, prospective short-circuit current and the applicable ABB interruption ratings. The relevant ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics) should be checked in the manufacturer's technical documentation before the device is specified.

The TMA designation identifies the manufacturer's thermal-magnetic trip arrangement. The precise thermal and magnetic adjustment ranges, available settings and operating curves must be established from the documentation for the supplied device. They should not be inferred solely from the XT1 frame designation or the 32 A nominal current.

Three-Pole Protection for Low-Voltage Distribution Circuits

The three-pole configuration enables the EPX-XT1S-TM0323 to provide coordinated switching and protection of three phase conductors within a suitable three-phase electrical system. This makes the device relevant to circuits supplying three-phase equipment, downstream electrical distribution arrangements and other appropriately designed loads.

Although the device has a 32 A current rating, its specified 50 kA breaking capacity addresses a different aspect of circuit protection. Rated current relates to the circuit breaker's nominal current-carrying and protection characteristics, while breaking capacity relates to its ability to interrupt a short-circuit fault under defined conditions.

A 32 A device with a 50 kA breaking capacity may therefore be appropriate where a relatively modest load current is supplied from a distribution system with a high prospective fault level. The actual suitability must be established through the electrical design, including conductor protection, operating voltage, prospective fault current and protective-device coordination.

The EPX-XT1S-TM0323 is a three-pole MCCB, not a four-pole device. Where the electrical design requires a four-pole configuration, ABB lists the separate EPX-XT1S-TM0324 32 A four-pole 50 kA thermal-magnetic MCCB. The correct pole arrangement must be selected according to the electrical system and applicable installation requirements.

Compact XT1S Circuit Breaker Platform

The ABB SACE Tmax XT1S platform is part of ABB's wider Tmax XT range of moulded case circuit breakers. The XT1 family provides a compact circuit breaker format for appropriately rated low-voltage distribution applications.

ABB's Protecta Power selection information identifies the XT1S three-pole outgoing device range with a nominal width of 80 mm. This value is useful when comparing the space allocated to different outgoing MCCB families within the Protecta Power system.

The nominal width should not be treated as the complete installed dimensions of the circuit breaker, mounting components, terminals and protective covers. The final assembly layout must be checked against the applicable ABB panelboard drawings and installation instructions.

Within the same 50 kA performance class, ABB lists related XT1S devices including the EPX-XT1S-TM0633 rated at 63 A and the EPX-XT1S-TM1603 rated at 160 A. These are separate products with different current ratings and must be selected according to the requirements of the protected circuit.

Protecta Power Installation and Accessory Selection

The ABB Protecta Power system provides coordinated low-voltage distribution assemblies, protective devices and installation accessories. The EPX-XT1S-TM0323 is intended for use in compatible outgoing MCCB positions, subject to the specific panelboard configuration.

Correct installation requires confirmation of the MCCB mounting arrangement, electrical connections, protective covering and available cable termination space. The device should be installed only in a configuration supported by the relevant ABB technical and assembly documentation.

The cable size must be determined from the circuit design rather than the MCCB frame designation alone. Relevant factors include conductor material, current-carrying capacity, installation method, ambient temperature, grouping, voltage drop, fault protection and terminal compatibility.

The appropriate mounting, connection and cover accessories must be selected for the intended Protecta Power assembly. The exact components supplied under ABB order code 1SDX248656R1 should be confirmed before ordering. A complete panelboard or additional installation accessories should not be assumed to be included unless expressly specified.

Installation, inspection and commissioning should be carried out by suitably competent personnel in accordance with ABB's instructions and applicable electrical installation standards. The final protective-device settings and coordination requirements should be established from the approved electrical design.

XT1S 50kA vs XT1N 36kA MCCBs

ABB offers the EPX-XT1S-TM0323 alongside the related EPX-XT1N-TM0323. Both are 32 A three-pole thermal-magnetic MCCBs within the XT1 family, but they have different specified breaking capacities.

The EPX-XT1S-TM0323 is specified at 50 kA, while the EPX-XT1N-TM0323 is specified at 36 kA. The correct performance class must be selected according to the prospective short-circuit current, applicable operating voltage and electrical protection requirements.

A higher specified breaking capacity does not change the nominal current rating of the device. Both variants remain 32 A circuit breakers, and the conductor protection and load assessment must be based on the actual device characteristics.

For installations requiring different current ratings or pole configurations, ABB provides additional XT1S variants. Selection should always be based on the electrical design and verified compatibility with the intended Protecta Power assembly.

Typical Applications

  • ABB Protecta Power outgoing circuit protection installations.
  • 32 A three-phase electrical distribution circuits.
  • Commercial building low-voltage distribution panelboards.
  • Industrial electrical distribution systems.
  • Three-phase plant and equipment supply circuits.
  • Electrical switchrooms and building services distribution installations.
  • Circuits requiring thermal-magnetic overload and short-circuit protection.
  • Installations where a suitably rated 50 kA outgoing MCCB is specified.
  • Distribution systems with relatively low outgoing circuit currents and higher prospective fault levels.
  • Switchboard manufacturing and electrical panel-building projects.
  • Compatible Protecta Power panelboard extensions and circuit additions.
  • Replacement of a correctly matched ABB Protecta Power XT1S protective device.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power
ABB order code 1SDX248656R1
Manufacturer product description EPX-XT1S-TM0323 32A 3P 50kA MCCB - TMA
Product type Moulded case circuit breaker
Product category Low-voltage circuit protection devices
Circuit breaker family ABB SACE Tmax XT
Device platform XT1S
Frame family XT1
Breaking-capacity class S
Rated current 32 A
Number of poles 3
Pole configuration 3P
Specified breaking capacity 50 kA
Protection technology Thermal-magnetic
Trip-unit designation TMA
Protection functions Overload and short-circuit protection
Nominal width listed for XT1S three-pole outgoing devices 80 mm
Primary application Three-phase low-voltage circuit protection
Associated distribution system ABB Protecta Power
Typical installation position Compatible outgoing MCCB arrangement
Operating voltage Confirm from the applicable ABB technical documentation
Applicable Icu and Ics ratings Verify at the intended operating voltage
Thermal and magnetic adjustment ranges Confirm for the supplied TMA trip unit
Terminal configuration Confirm against the supplied device and connection accessories
Maximum conductor capacity Dependent on the selected terminal arrangement
Mounting accessories Select according to the Protecta Power assembly
Related 32 A 36 kA variant EPX-XT1N-TM0323
Related 63 A 50 kA variant EPX-XT1S-TM0633
Related 32 A four-pole variant EPX-XT1S-TM0324

Frequently Asked Questions

What is the ABB EPX-XT1S-TM0323 used for?

The ABB EPX-XT1S-TM0323 is a 32 A three-pole moulded case circuit breaker designed for compatible ABB Protecta Power low-voltage distribution installations. It provides thermal-magnetic overload and short-circuit protection for appropriately designed three-phase electrical circuits.

What is the breaking capacity of the ABB EPX-XT1S-TM0323?

The EPX-XT1S-TM0323 has a manufacturer-specified 50 kA breaking capacity. The applicable interruption rating must be verified at the intended operating voltage using ABB's technical documentation, together with the prospective short-circuit current at the installation point.

What does TMA mean on the ABB EPX-XT1S-TM0323?

TMA identifies the circuit breaker's thermal-magnetic trip arrangement. The thermal element provides overload protection, while the magnetic element provides short-circuit protection. The exact adjustment ranges and operating characteristics must be confirmed from the documentation for the supplied device.

What is the difference between EPX-XT1S-TM0323 and EPX-XT1N-TM0323?

Both products are 32 A three-pole thermal-magnetic XT1 MCCBs. The EPX-XT1S-TM0323 has a specified breaking capacity of 50 kA, while the EPX-XT1N-TM0323 is specified at 36 kA. The correct version depends on the prospective fault current, operating voltage and electrical protection design.

What is the ABB order code for the EPX-XT1S-TM0323?

The ABB order code is 1SDX248656R1, and the model reference is EPX-XT1S-TM0323. The manufacturer product description is EPX-XT1S-TM0323 32A 3P 50kA MCCB - TMA, within the ABB Protecta Power Devices product group.

Trusted ABB Protecta Power Circuit Protection Solutions

ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage protective devices, panelboards and installation accessories. The EPX-XT1S-TM0323 combines a 32 A three-pole ABB SACE Tmax XT1S circuit breaker with 50 kA specified breaking capacity and thermal-magnetic TMA protection, supporting dependable outgoing circuit protection within compatible Protecta Power electrical distribution assemblies.