ABB EPX-XT1N-TM1603 Protecta Power 160 A three-pole Tmax XT1N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.
£563.00
The ABB EPX-XT1N-TM1603 is a 160 A, three-pole moulded case circuit breaker (MCCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Tmax XT1N circuit breaker family and the Protecta Power Devices range, this MCCB combines a compact design with a 36 kA specified breaking capacity and thermal-magnetic protection for commercial and industrial installations.
Featuring a TMA thermal-magnetic trip unit, the EPX-XT1N-TM1603 provides protection against sustained overloads and short-circuit faults. Its thermal protection element responds to excessive current over time, while the magnetic element provides rapid tripping during high fault current conditions. These complementary protective functions help safeguard electrical conductors, connected equipment and distribution infrastructure.
With a 160 A rated current and three-pole construction, the EPX-XT1N-TM1603 is suitable for appropriately designed three-phase distribution circuits and outgoing feeders. Its ABB Protecta Power configuration supports integration into compatible distribution assemblies, making it a practical choice for electrical contractors, engineers and panel builders requiring a compact, high-current protective device.
The ABB EPX-XT1N-TM1603 provides circuit protection for three-phase electrical installations requiring a 160 A moulded case circuit breaker. Its TMA thermal-magnetic trip arrangement responds to sustained overloads that can cause excessive conductor heating and short-circuit faults that require rapid interruption. These protective functions help reduce the risk of damage to electrical equipment and distribution infrastructure caused by overcurrent conditions.
The ABB Tmax XT1N platform provides a compact circuit protection solution for compatible Protecta Power panelboards and distribution assemblies. With its 36 kA specified breaking capacity, the EPX-XT1N-TM1603 can be considered for installations where the prospective short-circuit current falls within its applicable rating. Electrical designers should verify the operating voltage, conductor sizing, protective coordination, trip characteristics, terminal arrangements and compatibility with the intended distribution assembly before installation.
| Product model | EPX-XT1N-TM1603 |
|---|---|
| ABB order code | 1SDX248655R1 |
| Product group | Protecta Power Devices |
| Circuit breaker series | Tmax XT |
| Circuit breaker family | XT1N |
| Frame designation | XT1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 160 A |
| Number of poles | 3 |
| Specified breaking capacity | 36 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Operating mechanism | Manual circuit breaker operation |
| Electrical system | Low-voltage electrical distribution |
| Distribution arrangement | Three-pole, three-phase applications |
| Installation | Compatible ABB Protecta Power distribution assembly |
| Primary application | Overload and short-circuit protection |
The ABB EPX-XT1N-TM1603 is a 160 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.
The EPX-XT1N-TM1603 has a 160 A rated current and a specified 36 kA breaking capacity. The applicable breaking capacity must be verified against the operating voltage and prospective short-circuit current of the installation.
TMA identifies the thermal-magnetic trip unit configuration. The thermal element provides protection against sustained overloads, while the magnetic element responds to short-circuit faults. Exact trip adjustment ranges and operating characteristics should be confirmed using the relevant ABB technical documentation.
Yes. Its three-pole configuration is intended for three-phase electrical circuits requiring coordinated switching and protection of all three phases. Suitability depends on the system voltage, prospective fault current, conductor sizing and distribution assembly requirements.
Both models are 160 A three-pole ABB Tmax XT1 thermal-magnetic MCCBs. The EPX-XT1N-TM1603 has a specified 36 kA breaking capacity, while the EPX-XT1S-TM1603 has a specified 50 kA breaking capacity. Selection depends on the prospective short-circuit current, operating voltage and protection requirements of the installation.
ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage circuit protection. The EPX-XT1N-TM1603 combines a 160 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.