ABB EPX-XT1N-TM1003 Protecta Power 100 A three-pole Tmax XT1N moulded case circuit breaker with 36 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.
£357.48
The ABB EPX-XT1N-TM1003 is a 100 A, three-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Part of the ABB Tmax XT1N circuit breaker family and the Protecta Power Devices range, this MCCB combines a compact construction with a 36 kA specified breaking capacity and thermal-magnetic protection for commercial and industrial applications.
Featuring a TMA thermal-magnetic trip unit, the EPX-XT1N-TM1003 provides two essential protective functions. Its thermal element responds to sustained overload conditions, while its magnetic element provides rapid tripping during short-circuit faults. These functions help protect electrical conductors, connected equipment and distribution infrastructure against potentially damaging overcurrent conditions.
With a 100 A rated current, three-pole construction and the established ABB Tmax XT1N platform, the EPX-XT1N-TM1003 is suited to outgoing feeder protection and three-phase distribution circuits. Its Protecta Power configuration supports integration into compatible ABB electrical distribution assemblies, providing a practical solution for electrical contractors, engineers and panel builders.
The ABB EPX-XT1N-TM1003 provides protection for three-phase electrical circuits requiring a 100 A moulded case circuit breaker. Its thermal-magnetic trip arrangement responds to two different types of overcurrent condition: sustained overloads that can cause excessive conductor heating, and short-circuit faults that require rapid interruption. This combination makes the device suitable for protecting distribution feeders and connected electrical infrastructure.
The ABB Tmax XT1N platform offers a compact solution for low-voltage distribution applications where installation space, protective performance and compatibility with the distribution assembly are important considerations. The specified 36 kA breaking capacity must be assessed against the prospective fault current and operating voltage of the installation. Electrical designers should also verify conductor sizing, protective coordination, trip settings, terminal arrangements and compatibility with the intended ABB Protecta Power assembly before installation.
| Product model | EPX-XT1N-TM1003 |
|---|---|
| ABB order code | 1SDX248654R1 |
| Product group | Protecta Power Devices |
| Circuit breaker series | Tmax XT |
| Circuit breaker family | XT1N |
| Frame designation | XT1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 100 A |
| Number of poles | 3 |
| Specified breaking capacity | 36 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Operating mechanism | Manual circuit breaker operation |
| Electrical system | Low-voltage electrical distribution |
| Distribution arrangement | Three-pole, three-phase applications |
| Installation | Compatible ABB Protecta Power distribution assembly |
| Primary application | Overload and short-circuit protection |
The ABB EPX-XT1N-TM1003 is a 100 A three-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.
The EPX-XT1N-TM1003 has a 100 A rated current and a specified 36 kA breaking capacity. The applicable short-circuit breaking capacity must be verified against the operating voltage and prospective fault current of the installation.
TMA identifies the thermal-magnetic trip unit configuration. The thermal element provides overload protection, while the magnetic element responds to short-circuit faults. The applicable adjustment ranges and trip characteristics should be confirmed from ABB technical documentation for the exact circuit breaker configuration.
Yes. The three-pole configuration is designed for three-phase electrical circuits requiring coordinated switching and protection of all three phases. Suitability depends on the system voltage, prospective fault current, conductor sizing and distribution assembly requirements.
The EPX-XT1N-TM1003 is a 100 A three-pole XT1N thermal-magnetic MCCB with a specified 36 kA breaking capacity. The EPX-XT1S-TM1003 is a corresponding 100 A three-pole XT1S configuration with a specified 50 kA breaking capacity. Selection depends on the installation's prospective short-circuit current, operating voltage and protective requirements.
ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with established solutions for low-voltage electrical protection. The EPX-XT1N-TM1003 combines a 100 A rated current, three-pole construction, 36 kA specified breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.