1SDX248653R1 ABB EPX-XT1N-TM0633 Protecta Power 63A 3-Pole XT1N 36kA Thermal Magnetic MCCB

1SDX248653R1 ABB EPX-XT1N-TM0633 Protecta Power 63A 3-Pole XT1N 36kA Thermal Magnetic MCCB

ABB EPX-XT1N-TM0633 (1SDX248653R1) 63 A three-pole Tmax XT1N thermal-magnetic outgoing MCCB with a 36 kA breaking-capacity classification for compatible ABB Protecta Power electrical distribution panelboards.

SKU: 1SDX248653R1Alt SKU: EPX-XT1N-TM0633MPN: 1SDX248653R1
Price
List Price £348.06 ex VAT
Your Price (ex VAT)
£348.06
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £348.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£348.06

Why Choose the ABB EPX-XT1N-TM0633 63A Three-Pole 36kA Thermal-Magnetic MCCB?

The ABB EPX-XT1N-TM0633 is a 63 A three-pole moulded case circuit breaker (MCCB) with a 36 kA breaking-capacity classification, designed for compatible ABB Protecta Power electrical distribution panelboards. Identified by manufacturer order code 1SDX248653R1, this protective device belongs to the Protecta Power Devices product group and provides a dedicated outgoing circuit protection solution for low-voltage electrical distribution installations.

Based on the ABB SACE Tmax XT1N circuit breaker platform, the EPX-XT1N-TM0633 uses thermal-magnetic (TMA) protection to respond to overload and short-circuit conditions. Its 63 A rated current and three-pole (3P) configuration make it suitable for appropriately designed three-phase outgoing circuits where coordinated switching and overcurrent protection of all three phase conductors are required.

ABB's Protecta Power selection literature identifies the EPX-XT1N-TM0633 within its 63 A, three-pole, 36 kA thermal-magnetic MCCB range. The XT1 platform offers a compact arrangement for compatible outgoing positions, with a published 80 mm three-pole device width. This combination of current rating, pole configuration, protection technology and ABB product identification makes the EPX-XT1N-TM0633 a practical specification choice for electrical contractors, consulting engineers and professional panel builders.

Key Advantages

  • Purpose-designed 63 A outgoing MCCB for compatible ABB Protecta Power electrical distribution panelboards.
  • Three-pole (3P) configuration for suitable three-phase outgoing circuit protection.
  • Based on the ABB SACE Tmax XT1N moulded case circuit breaker platform.
  • Provides thermal-magnetic overload and short-circuit protection.
  • Specified with a 36 kA breaking-capacity classification, subject to verification of the applicable rated operational voltage.
  • Combines manual circuit switching with automatic overcurrent tripping.
  • Supports simultaneous operation of the three protected poles through a common breaker mechanism.
  • Compact 80 mm three-pole device width identified in ABB Protecta Power selection literature.
  • Supports coordinated outgoing circuit protection within compatible ABB distribution assemblies.
  • Provides a clearly identified 63 A option within the wider XT1N outgoing MCCB range.
  • Suitable for professional commercial, industrial and institutional low-voltage distribution applications.
  • Genuine ABB product identified by manufacturer order code 1SDX248653R1.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT1N-TM0633 manufacturer product reference.
  • 63 A rated current.
  • Three-pole (3P) circuit breaker configuration.
  • ABB SACE Tmax XT1 circuit breaker platform.
  • XT1N device variant.
  • XT1 frame family for compatible outgoing MCCB applications.
  • Thermal-magnetic (TMA) protection designation.
  • Thermal response to sustained overload conditions.
  • Magnetic response to short-circuit conditions.
  • 36 kA published breaking-capacity classification.
  • 80 mm published XT1 three-pole device width.
  • Designed for compatible ABB Protecta Power outgoing circuit positions.
  • Manual switching and automatic protective tripping.
  • Suitable for integration with an appropriately selected outgoing MCCB mounting arrangement.
  • ABB manufacturer order code 1SDX248653R1.

63A Three-Phase Outgoing Circuit Protection with ABB Tmax XT1N Technology

Outgoing circuit protection is an essential element of a professionally designed low-voltage distribution system. Each circuit breaker must be selected according to the connected electrical load, conductor characteristics, installation conditions and prospective fault current. The ABB EPX-XT1N-TM0633 provides a 63 A three-pole MCCB solution for compatible Protecta Power assemblies, helping protect the connected circuit against overload and short-circuit conditions.

The product uses the ABB SACE Tmax XT1N circuit breaker platform. The XT1 designation identifies the circuit breaker frame family, while the N designation identifies the relevant device variant. The 63 A current rating specifies the rating of this particular outgoing protective device and must be considered when selecting suitable conductors and connected equipment.

The thermal-magnetic protection arrangement combines two complementary overcurrent protection functions. The thermal element responds to sustained overload conditions that may cause excessive heating in electrical conductors and equipment. The magnetic element responds to sufficiently high short-circuit currents, providing rapid protective tripping when its operating threshold is reached. The precise operating characteristics and any available adjustment settings must be confirmed from ABB's technical documentation.

The three-pole configuration makes the EPX-XT1N-TM0633 suitable for appropriately designed three-phase circuits. The three protected poles operate together through the circuit breaker's common mechanism, enabling coordinated disconnection of the phase conductors. This is particularly relevant for three-phase distribution circuits where the electrical design requires common switching and protective operation.

ABB's Protecta Power selection literature lists the EPX-XT1N-TM0633 as a 63 A, three-pole, 36 kA thermal-magnetic MCCB. The 36 kA classification is an important part of the product specification, but the electrical designer must verify the applicable breaking-capacity rating at the intended operational voltage. The manufacturer's detailed data should be consulted for the relevant ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics).

The 63 A rating distinguishes this model from other XT1N outgoing circuit breakers, including the 32 A EPX-XT1N-TM0323 and higher-rated variants within the same family. Devices with different current ratings should not be substituted without checking the circuit design. The selected protective device must be suitable for the load, conductor current-carrying capacity, fault protection requirements and applicable installation regulations.

ABB's Protecta Power selection literature identifies the XT1 three-pole device width as 80 mm. This provides a useful reference for panelboard device selection and layout planning. However, the published width should not be interpreted as the total installed space requirement, as the completed assembly may also require mounting components, covers, cable termination space and appropriate electrical clearances.

The ABB Protecta Power system uses coordinated outgoing MCCB mounting arrangements to integrate circuit breakers into compatible distribution assemblies. The appropriate XT1 three-pole base plate, cover and associated installation components must be selected for the intended panelboard. These components should be checked against the current ABB installation instructions and ordering information rather than assumed to be included with the circuit breaker.

When designing a three-phase outgoing circuit, the prospective short-circuit current at the installation point must be considered alongside the circuit breaker's breaking-capacity rating. Where protective coordination, discrimination or backup protection is required, the designer should refer to ABB's published coordination tables. The use of devices from the same manufacturer does not automatically guarantee selectivity under every fault condition.

Before installation, the electrical designer must verify the rated operational voltage, breaking capacity, thermal-magnetic trip characteristics, conductor termination requirements, mounting arrangement and panelboard compatibility. The completed distribution assembly must also satisfy applicable electrical installation and low-voltage switchgear assembly requirements. Installation, inspection and commissioning should be carried out by competent electrical personnel using current ABB technical documentation.

Typical Applications

  • ABB Protecta Power outgoing electrical distribution circuits.
  • 63 A three-pole MCCB protection within compatible panelboards.
  • Three-phase outgoing circuits requiring thermal-magnetic overcurrent protection.
  • Commercial building low-voltage distribution systems.
  • Industrial electrical distribution panelboards.
  • Appropriately designed three-phase machinery supply circuits.
  • Electrical plant and equipment distribution.
  • Office buildings and retail developments.
  • Warehouses and logistics facilities.
  • Manufacturing and light industrial premises.
  • Educational and institutional electrical infrastructure.
  • Electrical switchrooms and sub-distribution assemblies.
  • Professional electrical panel building and switchgear manufacturing.
  • Compatible outgoing MCCB replacement and refurbishment projects.

Technical Specifications

Product group Protecta Power Devices
Compatible distribution range ABB Protecta Power
ABB order code 1SDX248653R1
Manufacturer product description 63A 3P 36kA MCCB - TMA
Product type Moulded case circuit breaker (MCCB)
Device application Outgoing circuit protection
Rated current 63 A
Number of poles 3P (three-pole)
Circuit breaker platform ABB SACE Tmax XT1
Device variant XT1N
Frame family XT1
Protection technology Thermal-magnetic
Trip designation TMA
Overload protection Thermal trip function
Short-circuit protection Magnetic trip function
Published breaking-capacity classification 36 kA
Breaking-capacity verification Confirm applicable rated operational voltage and detailed ABB Icu/Ics ratings
Published XT1 three-pole device width 80 mm
Mounting arrangement Compatible ABB Protecta Power outgoing MCCB assembly
Associated installation components Appropriate XT1 three-pole mounting accessories and protective covers, as specified for the panelboard
Operating functionality Manual switching and automatic overcurrent tripping
System type Low-voltage electrical distribution
Intended installation position Compatible outgoing distribution circuit
Typical circuit arrangement Three-phase outgoing circuit

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0633 used for?

The ABB EPX-XT1N-TM0633 is a 63 A three-pole thermal-magnetic MCCB designed for compatible ABB Protecta Power outgoing distribution circuits. It provides overload and short-circuit protection using the ABB SACE Tmax XT1N circuit breaker platform.

What does TMA mean on the ABB EPX-XT1N-TM0633?

TMA identifies the device's thermal-magnetic protection arrangement. The thermal element responds to sustained overload conditions, while the magnetic element responds to short-circuit conditions. The exact trip characteristics and available adjustment settings must be confirmed from the relevant ABB technical documentation.

What is the current rating and pole configuration of the EPX-XT1N-TM0633?

The EPX-XT1N-TM0633 has a 63 A current rating and a three-pole (3P) configuration. It belongs to the ABB SACE Tmax XT1N circuit breaker range and is intended for suitable three-phase outgoing circuit protection applications.

What is the breaking capacity of the ABB EPX-XT1N-TM0633?

The EPX-XT1N-TM0633 is specified as a 36 kA MCCB. The applicable short-circuit breaking capacity must be verified at the intended operational voltage, including the relevant Icu and Ics ratings, before the device is selected for an installation.

Does the ABB EPX-XT1N-TM0633 require additional mounting components?

The EPX-XT1N-TM0633 must be installed using the appropriate ABB Protecta Power outgoing MCCB mounting arrangement. The compatible XT1 three-pole base plate, protective cover and any associated installation components should be confirmed against the selected panelboard and current ABB documentation. These components should not be assumed to be included with the circuit breaker.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB Protecta Power provides coordinated low-voltage electrical distribution components for commercial and industrial installations. The EPX-XT1N-TM0633 combines a 63 A three-pole Tmax XT1N circuit breaker with thermal-magnetic protection and a 36 kA breaking-capacity classification, offering electrical contractors and panel builders a clearly identified outgoing protective device for compatible Protecta Power assemblies.