Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-XT1N-TM0323 (1SDX248652R1) 32 A three-pole Tmax XT1N thermal-magnetic outgoing MCCB with a 36 kA breaking-capacity classification for compatible ABB Protecta Power distribution panelboards.
£348.06
The ABB EPX-XT1N-TM0323 is a 32 A three-pole moulded case circuit breaker (MCCB) with a 36 kA breaking-capacity classification, designed for compatible ABB Protecta Power electrical distribution panelboards. Identified by ABB manufacturer order code 1SDX248652R1, this device belongs to the Protecta Power Devices product group and provides an outgoing circuit protection solution for professional low-voltage electrical installations.
Based on the ABB SACE Tmax XT1N circuit breaker platform, the EPX-XT1N-TM0323 uses thermal-magnetic (TMA) protection to respond to overload and short-circuit conditions. Its 32 A current rating and three-pole (3P) configuration make it suitable for appropriately designed three-phase outgoing circuits where simultaneous switching of the three protected poles is required.
ABB's Protecta Power selection literature lists the EPX-XT1N-TM0323 within its three-pole, 36 kA thermal-magnetic MCCB range. The XT1 platform provides a compact circuit breaker arrangement for compatible outgoing positions, with a published device mounting width of 80 mm in the Protecta Power selection table. For electrical contractors, consulting engineers and panel builders, this genuine ABB product offers a clearly identified combination of current rating, pole configuration, breaking-capacity class and thermal-magnetic protection technology.
Outgoing circuit breakers form an essential part of a low-voltage electrical distribution system. Each protective device must be selected to suit the connected load, conductor characteristics, installation conditions and prospective fault current. The ABB EPX-XT1N-TM0323 provides a 32 A three-pole MCCB solution for compatible Protecta Power assemblies, helping protect the connected circuit against overload and short-circuit conditions.
The device is based on the ABB SACE Tmax XT1N platform. The XT1 designation identifies the circuit breaker frame family, while the N designation identifies the relevant device variant. The 32 A rating specifies the current rating of this particular outgoing protective device. These characteristics should be considered together when selecting a circuit breaker for an electrical distribution installation.
The thermal-magnetic protection arrangement provides two complementary overcurrent protection functions. The thermal element responds to sustained overload conditions that can cause excessive heating in conductors and electrical equipment. The magnetic element responds to sufficiently high short-circuit currents, providing rapid protective tripping when its operating threshold is reached.
The three-pole configuration makes the EPX-XT1N-TM0323 suitable for appropriately designed three-phase circuits. A three-pole MCCB operates the three protected poles together, allowing the connected circuit to be disconnected through a common switching mechanism. This is particularly relevant where the electrical design requires coordinated switching and overcurrent protection of the three phase conductors.
ABB's Protecta Power selection literature identifies the EPX-XT1N-TM0323 as a 32 A, three-pole, 36 kA thermal-magnetic MCCB. The 36 kA figure is a key catalogue classification, but it must be interpreted alongside the applicable rated operational voltage and the manufacturer's detailed breaking-capacity information. Electrical designers should verify the relevant ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics) before specifying the device.
The ABB Protecta Power range includes multiple XT1N thermal-magnetic outgoing MCCBs with different current ratings. Selecting the 32 A version helps match the protective device to a circuit designed for that rating. Higher-rated breakers should not be substituted simply because they share the same XT1 platform, as the selected overcurrent characteristics must remain appropriate for the connected conductors and equipment.
ABB's Protecta Power selection table identifies the XT1 three-pole device width as 80 mm. This dimension assists with panelboard device selection and arrangement planning. It should not be interpreted as the complete installed space requirement, which may also depend on mounting accessories, terminal arrangements, cable routing, shrouding and the enclosure design.
For outgoing XT1 three-pole MCCBs, ABB identifies the EPX-BPCXT1-3P outgoing MCCB base plate and cover. The manufacturer's selection literature states that an MCCB base plate and cover are required with each outgoing device and are to be ordered separately. The EPX-XT1N-TM0323 should therefore be considered a circuit breaker for integration into a compatible assembly, rather than a complete enclosed distribution product.
Correct installation also requires consideration of the incoming supply arrangement, panelboard busbar system and upstream protective device. A 32 A outgoing MCCB must be selected with adequate breaking capacity for the prospective short-circuit current at its installed position. Where selectivity or backup protection is required, the designer should consult ABB's published coordination information rather than assuming that two protective devices will operate selectively.
Before installation, the electrical designer must confirm the rated operational voltage, breaking capacity, thermal-magnetic trip characteristics, terminal suitability, conductor sizes and panelboard compatibility. The complete assembly must also meet applicable electrical installation and low-voltage switchgear assembly requirements. Installation, inspection and commissioning should be undertaken by competent electrical personnel using the current ABB documentation.
| Product group | Protecta Power Devices |
|---|---|
| Compatible distribution range | ABB Protecta Power |
| ABB order code | 1SDX248652R1 |
| Manufacturer product description | 32A 3P 36kA MCCB - TMA |
| Product type | Moulded case circuit breaker (MCCB) |
| Device application | Outgoing circuit protection |
| Rated current | 32 A |
| Number of poles | 3P (three-pole) |
| Circuit breaker platform | ABB SACE Tmax XT1 |
| Device variant | XT1N |
| Protection technology | Thermal-magnetic |
| Trip designation | TMA |
| Overload protection | Thermal trip function |
| Short-circuit protection | Magnetic trip function |
| Published breaking-capacity classification | 36 kA |
| Breaking-capacity verification | Confirm the applicable rated operational voltage and detailed ABB Icu/Ics ratings |
| Published XT1 three-pole device width | 80 mm |
| Associated mounting accessory | EPX-BPCXT1-3P outgoing MCCB base plate and cover |
| Mounting accessory supply | Ordered separately where required by the panelboard configuration |
| Operating functionality | Manual switching and automatic overcurrent tripping |
| System type | Low-voltage electrical distribution |
| Intended installation position | Compatible outgoing distribution circuit |
| Typical circuit arrangement | Three-phase outgoing circuit |
The ABB EPX-XT1N-TM0323 is a 32 A three-pole thermal-magnetic MCCB designed for compatible ABB Protecta Power outgoing distribution circuits. It provides overload and short-circuit protection using the ABB SACE Tmax XT1N circuit breaker platform.
TMA identifies the device's thermal-magnetic protection arrangement. The thermal element responds to sustained overload conditions, while the magnetic element responds to short-circuit conditions. The exact trip characteristics and available adjustment settings must be confirmed from the relevant ABB device documentation.
The EPX-XT1N-TM0323 has a 32 A current rating and a three-pole (3P) configuration. It belongs to the ABB SACE Tmax XT1N circuit breaker range and is intended for suitable three-phase outgoing circuit protection applications.
ABB's Protecta Power selection literature lists the EPX-XT1N-TM0323 as a 36 kA MCCB. The applicable short-circuit breaking capacity must be verified at the intended operational voltage, including the relevant Icu and Ics ratings, before the device is selected for an installation.
Yes. ABB's Protecta Power selection literature specifies that an MCCB base plate and cover are required with each outgoing device. The corresponding accessory for an XT1 three-pole outgoing MCCB is EPX-BPCXT1-3P, which should be ordered separately where required by the approved panelboard configuration.
ABB Protecta Power provides coordinated low-voltage electrical distribution components for commercial and industrial installations. The EPX-XT1N-TM0323 combines a 32 A three-pole Tmax XT1N circuit breaker with thermal-magnetic protection and a published 36 kA breaking-capacity classification, offering electrical contractors and panel builders a clearly identified outgoing protective device for compatible Protecta Power assemblies.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.