ABB EPX-XT1N-TM0323 (1SDX248652R1) 32 A three-pole Tmax XT1N thermal-magnetic outgoing MCCB with a 36 kA breaking-capacity classification for compatible ABB Protecta Power distribution panelboards.

SKU: 1SDX248652R1Alt SKU: EPX-XT1N-TM0323MPN: 1SDX248652R1
Price
List Price £348.06 ex VAT
Your Price (ex VAT)
£348.06
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £348.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£348.06

Why Choose the ABB EPX-XT1N-TM0323 32A Three-Pole 36kA Thermal-Magnetic MCCB?

The ABB EPX-XT1N-TM0323 is a 32 A three-pole moulded case circuit breaker (MCCB) with a 36 kA breaking-capacity classification, designed for compatible ABB Protecta Power electrical distribution panelboards. Identified by ABB manufacturer order code 1SDX248652R1, this device belongs to the Protecta Power Devices product group and provides an outgoing circuit protection solution for professional low-voltage electrical installations.

Based on the ABB SACE Tmax XT1N circuit breaker platform, the EPX-XT1N-TM0323 uses thermal-magnetic (TMA) protection to respond to overload and short-circuit conditions. Its 32 A current rating and three-pole (3P) configuration make it suitable for appropriately designed three-phase outgoing circuits where simultaneous switching of the three protected poles is required.

ABB's Protecta Power selection literature lists the EPX-XT1N-TM0323 within its three-pole, 36 kA thermal-magnetic MCCB range. The XT1 platform provides a compact circuit breaker arrangement for compatible outgoing positions, with a published device mounting width of 80 mm in the Protecta Power selection table. For electrical contractors, consulting engineers and panel builders, this genuine ABB product offers a clearly identified combination of current rating, pole configuration, breaking-capacity class and thermal-magnetic protection technology.

Key Advantages

  • Purpose-designed 32 A outgoing MCCB for compatible ABB Protecta Power distribution panelboards.
  • Three-pole (3P) configuration for suitable three-phase outgoing circuits.
  • Based on the ABB SACE Tmax XT1N moulded case circuit breaker platform.
  • Provides thermal-magnetic overload and short-circuit protection.
  • Listed with a 36 kA breaking-capacity classification in ABB's Protecta Power selection literature.
  • Combines manual circuit switching with automatic overcurrent tripping.
  • Offers a compact 80 mm device width classification within the Protecta Power outgoing MCCB range.
  • Supports coordinated protection of appropriately designed three-phase distribution circuits.
  • Provides a clearly identified alternative to higher-current XT1 devices and other XT frame sizes.
  • Designed for integration with the appropriate ABB Protecta Power outgoing MCCB base plate and cover.
  • Suitable for professional commercial, industrial and institutional electrical distribution installations.
  • Genuine ABB product identified by manufacturer order code 1SDX248652R1.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT1N-TM0323 product reference.
  • 32 A rated current.
  • Three-pole (3P) circuit breaker configuration.
  • ABB SACE Tmax XT1N circuit breaker platform.
  • XT1 frame family for compatible outgoing MCCB applications.
  • Thermal-magnetic (TMA) protection designation.
  • Thermal overload protection function.
  • Magnetic short-circuit protection function.
  • 36 kA published breaking-capacity classification.
  • 80 mm XT1 three-pole device width identified in Protecta Power selection literature.
  • Designed for compatible ABB Protecta Power outgoing circuit positions.
  • Manual switching and automatic protective tripping.
  • Compatible with the appropriate XT1 three-pole outgoing MCCB base plate and cover.
  • Part of ABB's broader XT1N three-pole thermal-magnetic outgoing device range.
  • ABB manufacturer order code 1SDX248652R1.

32A Three-Phase Circuit Protection with ABB Tmax XT1N Thermal-Magnetic Technology

Outgoing circuit breakers form an essential part of a low-voltage electrical distribution system. Each protective device must be selected to suit the connected load, conductor characteristics, installation conditions and prospective fault current. The ABB EPX-XT1N-TM0323 provides a 32 A three-pole MCCB solution for compatible Protecta Power assemblies, helping protect the connected circuit against overload and short-circuit conditions.

The device is based on the ABB SACE Tmax XT1N platform. The XT1 designation identifies the circuit breaker frame family, while the N designation identifies the relevant device variant. The 32 A rating specifies the current rating of this particular outgoing protective device. These characteristics should be considered together when selecting a circuit breaker for an electrical distribution installation.

The thermal-magnetic protection arrangement provides two complementary overcurrent protection functions. The thermal element responds to sustained overload conditions that can cause excessive heating in conductors and electrical equipment. The magnetic element responds to sufficiently high short-circuit currents, providing rapid protective tripping when its operating threshold is reached.

The three-pole configuration makes the EPX-XT1N-TM0323 suitable for appropriately designed three-phase circuits. A three-pole MCCB operates the three protected poles together, allowing the connected circuit to be disconnected through a common switching mechanism. This is particularly relevant where the electrical design requires coordinated switching and overcurrent protection of the three phase conductors.

ABB's Protecta Power selection literature identifies the EPX-XT1N-TM0323 as a 32 A, three-pole, 36 kA thermal-magnetic MCCB. The 36 kA figure is a key catalogue classification, but it must be interpreted alongside the applicable rated operational voltage and the manufacturer's detailed breaking-capacity information. Electrical designers should verify the relevant ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics) before specifying the device.

The ABB Protecta Power range includes multiple XT1N thermal-magnetic outgoing MCCBs with different current ratings. Selecting the 32 A version helps match the protective device to a circuit designed for that rating. Higher-rated breakers should not be substituted simply because they share the same XT1 platform, as the selected overcurrent characteristics must remain appropriate for the connected conductors and equipment.

ABB's Protecta Power selection table identifies the XT1 three-pole device width as 80 mm. This dimension assists with panelboard device selection and arrangement planning. It should not be interpreted as the complete installed space requirement, which may also depend on mounting accessories, terminal arrangements, cable routing, shrouding and the enclosure design.

For outgoing XT1 three-pole MCCBs, ABB identifies the EPX-BPCXT1-3P outgoing MCCB base plate and cover. The manufacturer's selection literature states that an MCCB base plate and cover are required with each outgoing device and are to be ordered separately. The EPX-XT1N-TM0323 should therefore be considered a circuit breaker for integration into a compatible assembly, rather than a complete enclosed distribution product.

Correct installation also requires consideration of the incoming supply arrangement, panelboard busbar system and upstream protective device. A 32 A outgoing MCCB must be selected with adequate breaking capacity for the prospective short-circuit current at its installed position. Where selectivity or backup protection is required, the designer should consult ABB's published coordination information rather than assuming that two protective devices will operate selectively.

Before installation, the electrical designer must confirm the rated operational voltage, breaking capacity, thermal-magnetic trip characteristics, terminal suitability, conductor sizes and panelboard compatibility. The complete assembly must also meet applicable electrical installation and low-voltage switchgear assembly requirements. Installation, inspection and commissioning should be undertaken by competent electrical personnel using the current ABB documentation.

Typical Applications

  • ABB Protecta Power outgoing electrical distribution circuits.
  • 32 A three-pole MCCB protection within compatible panelboards.
  • Three-phase outgoing circuits requiring thermal-magnetic overcurrent protection.
  • Commercial building low-voltage distribution systems.
  • Industrial electrical distribution panelboards.
  • Appropriately designed three-phase machinery supply circuits.
  • Electrical plant and equipment distribution.
  • Office buildings and retail developments.
  • Warehouses and logistics facilities.
  • Manufacturing and light industrial premises.
  • Educational and institutional electrical infrastructure.
  • Electrical switchrooms and sub-distribution assemblies.
  • Professional electrical panel building and switchgear manufacturing.
  • Compatible outgoing MCCB replacement and refurbishment projects.

Technical Specifications

Product group Protecta Power Devices
Compatible distribution range ABB Protecta Power
ABB order code 1SDX248652R1
Manufacturer product description 32A 3P 36kA MCCB - TMA
Product type Moulded case circuit breaker (MCCB)
Device application Outgoing circuit protection
Rated current 32 A
Number of poles 3P (three-pole)
Circuit breaker platform ABB SACE Tmax XT1
Device variant XT1N
Protection technology Thermal-magnetic
Trip designation TMA
Overload protection Thermal trip function
Short-circuit protection Magnetic trip function
Published breaking-capacity classification 36 kA
Breaking-capacity verification Confirm the applicable rated operational voltage and detailed ABB Icu/Ics ratings
Published XT1 three-pole device width 80 mm
Associated mounting accessory EPX-BPCXT1-3P outgoing MCCB base plate and cover
Mounting accessory supply Ordered separately where required by the panelboard configuration
Operating functionality Manual switching and automatic overcurrent tripping
System type Low-voltage electrical distribution
Intended installation position Compatible outgoing distribution circuit
Typical circuit arrangement Three-phase outgoing circuit

Frequently Asked Questions

What is the ABB EPX-XT1N-TM0323 used for?

The ABB EPX-XT1N-TM0323 is a 32 A three-pole thermal-magnetic MCCB designed for compatible ABB Protecta Power outgoing distribution circuits. It provides overload and short-circuit protection using the ABB SACE Tmax XT1N circuit breaker platform.

What does TMA mean on the ABB EPX-XT1N-TM0323?

TMA identifies the device's thermal-magnetic protection arrangement. The thermal element responds to sustained overload conditions, while the magnetic element responds to short-circuit conditions. The exact trip characteristics and available adjustment settings must be confirmed from the relevant ABB device documentation.

What is the current rating and pole configuration of the EPX-XT1N-TM0323?

The EPX-XT1N-TM0323 has a 32 A current rating and a three-pole (3P) configuration. It belongs to the ABB SACE Tmax XT1N circuit breaker range and is intended for suitable three-phase outgoing circuit protection applications.

What is the breaking capacity of the ABB EPX-XT1N-TM0323?

ABB's Protecta Power selection literature lists the EPX-XT1N-TM0323 as a 36 kA MCCB. The applicable short-circuit breaking capacity must be verified at the intended operational voltage, including the relevant Icu and Ics ratings, before the device is selected for an installation.

Does the ABB EPX-XT1N-TM0323 require a separate base plate and cover?

Yes. ABB's Protecta Power selection literature specifies that an MCCB base plate and cover are required with each outgoing device. The corresponding accessory for an XT1 three-pole outgoing MCCB is EPX-BPCXT1-3P, which should be ordered separately where required by the approved panelboard configuration.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB Protecta Power provides coordinated low-voltage electrical distribution components for commercial and industrial installations. The EPX-XT1N-TM0323 combines a 32 A three-pole Tmax XT1N circuit breaker with thermal-magnetic protection and a published 36 kA breaking-capacity classification, offering electrical contractors and panel builders a clearly identified outgoing protective device for compatible Protecta Power assemblies.