1SDX248647R1 ABB EPX-XT5S-E1-4004 400A 4P 50kA LS/I Electronic Moulded Case Circuit Breaker

1SDX248647R1 ABB EPX-XT5S-E1-4004 400A 4P 50kA LS/I Electronic Moulded Case Circuit Breaker

ABB EPX-XT5S-E1-4004 (1SDX248647R1) is a 400 A four-pole SACE Tmax XT5S moulded case circuit breaker with a 50 kA breaking capacity at 415 V AC and Ekip Dip LS/I electronic protection for compatible ABB Protecta Power distribution systems.

SKU: 1SDX248647R1Alt SKU: EPX-XT5S-E1-4004MPN: 1SDX248647R1
Price
List Price £2,006.36 ex VAT
Your Price (ex VAT)
£2,006.36
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,006.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,006.36

Why Choose the ABB EPX-XT5S-E1-4004 400A 4-Pole Electronic MCCB?

The ABB EPX-XT5S-E1-4004 is a high-performance 400 A four-pole moulded case circuit breaker (MCCB) designed to provide advanced overload and short-circuit protection in low-voltage electrical distribution systems. Based on the ABB SACE Tmax XT5S400 circuit breaker platform, this device combines robust electrical protection with an intelligent electronic trip unit for reliable operation in commercial and industrial power distribution installations.

As part of the ABB Protecta Power Devices product group, the EPX-XT5S-E1-4004 is designed for integration into compatible ABB Protecta Power distribution assemblies. Its Ekip Dip LS/I electronic trip unit provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection characteristics. This electronic protection technology enables more flexible circuit protection coordination than conventional thermal-magnetic trip systems.

With a rated current of 400 A, a 50 kA short-circuit breaking capacity at 415 V AC and a four-pole (4P) configuration, the EPX-XT5S-E1-4004 is ideal for high-capacity outgoing feeders, electrical distribution boards and industrial power systems. Its compact XT5S construction and electronic protection functionality make it a dependable solution for electrical contractors, switchboard manufacturers, panel builders and facilities engineers.

Key Advantages

  • High-performance 400 A moulded case circuit breaker for commercial and industrial power distribution.
  • 50 kA short-circuit breaking capacity at 415 V AC for demanding electrical installations.
  • Four-pole (4P) configuration for coordinated switching of three phase conductors and a neutral conductor.
  • Advanced Ekip Dip LS/I electronic trip unit for overload and short-circuit protection.
  • Selectable short-time (S) or instantaneous (I) protection supports circuit protection coordination.
  • Based on the established ABB SACE Tmax XT5S400 platform.
  • Designed for integration into ABB Protecta Power distribution boards.
  • Electronic protection settings support accurate and consistent fault response.
  • Robust moulded case construction helps ensure dependable operation in demanding electrical environments.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-XT5S-E1-4004 product designation.
  • ABB order code 1SDX248647R1.
  • ABB SACE Tmax XT5S400 circuit breaker platform.
  • 400 A rated current for high-capacity electrical distribution circuits.
  • 400 A frame rating within the XT5S400 platform.
  • 50 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Four-pole (4P) configuration for three-phase distribution systems with a neutral conductor.
  • Ekip Dip LS/I electronic protection with configurable trip characteristics.
  • Long-time (L) overload protection for sustained overcurrent conditions.
  • Selectable short-time (S) or instantaneous (I) short-circuit protection.
  • Electronic trip technology supports protection coordination with downstream electrical devices.
  • 190 mm nominal device width for the XT5S four-pole configuration.
  • Designed for installation in compatible ABB Protecta Power distribution assemblies.
  • Suitable for commercial, industrial and building services electrical distribution systems.

Advanced Electronic Circuit Protection for Industrial Power Distribution

Electronic moulded case circuit breakers such as the ABB EPX-XT5S-E1-4004 protect electrical distribution systems by monitoring current and interrupting the circuit when abnormal operating conditions occur. Unlike conventional thermal-magnetic breakers, the Ekip Dip electronic trip unit uses electronic protection technology to provide configurable operating characteristics for overload and short-circuit faults.

The LS/I protection configuration provides long-time overload protection together with a choice between short-time delayed and instantaneous short-circuit protection. Long-time protection helps prevent damage caused by sustained excessive current, while the selectable short-circuit protection characteristic enables engineers to adapt the breaker response to the electrical distribution network. This flexibility supports improved selectivity and coordination between upstream and downstream protective devices.

The ABB SACE Tmax XT5S400 platform is engineered for reliable high-current circuit protection. Its four-pole construction enables coordinated switching of three phase conductors and a neutral conductor in suitable electrical installations. The electronic trip system and 400 A rated current make the EPX-XT5S-E1-4004 particularly suitable for high-capacity outgoing feeders and distribution circuits in compatible ABB Protecta Power assemblies.

For XT5 outgoing circuit breakers, ABB recommends considering a side cableway extension box where larger cables require additional installation space. Final selection of protection settings, neutral configuration, installation accessories and short-circuit ratings should be based on the complete electrical distribution system design and applicable ABB technical documentation.

Typical Applications

  • ABB Protecta Power low-voltage electrical distribution boards.
  • High-capacity outgoing feeder protection in commercial buildings.
  • Industrial power distribution systems and manufacturing facilities.
  • Three-phase and neutral electrical distribution circuits.
  • Commercial building main and sub-distribution installations.
  • Electrical distribution for warehouses, logistics centres and industrial premises.
  • Building services infrastructure and mechanical plant distribution systems.
  • Electrical switchboard manufacturing and power distribution panel assembly.

Technical Specifications

Product group Protecta Power Devices
Series SACE Tmax XT
Circuit breaker platform XT5S400
ABB order code 1SDX248647R1
Product type Electronic moulded case circuit breaker (MCCB)
Rated current 400 A
Frame rating 400 A
Ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Number of poles 4
Pole configuration Four-pole (4P)
Trip unit Ekip Dip LS/I electronic release
Trip technology Electronic
Long-time protection (L) Overload protection
Short-time protection (S) Delayed short-circuit protection, selectable within the LS/I configuration
Instantaneous protection (I) Instantaneous short-circuit protection, selectable within the LS/I configuration
Protection configuration L with selectable S or I characteristics
Applicable standard IEC 60947-2
Nominal device width 190 mm
Mounting type Compatible ABB Protecta Power distribution assembly
Installation Fixed distribution board installation using compatible mounting and connection accessories
Application Three-phase low-voltage electrical power distribution

Frequently Asked Questions

What is the ABB EPX-XT5S-E1-4004 used for?

The ABB EPX-XT5S-E1-4004 is a 400 A four-pole electronic moulded case circuit breaker designed to protect high-current electrical distribution circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.

What is the rated current and breaking capacity of this circuit breaker?

The EPX-XT5S-E1-4004 has a 400 A rated current and a 50 kA ultimate short-circuit breaking capacity at 415 V AC. Its ABB XT5S400 platform is designed for high-performance low-voltage circuit protection. The prospective fault current and operating voltage of the installation must be considered when selecting the breaker.

What does LS/I mean on the ABB EPX-XT5S-E1-4004?

LS/I identifies the electronic protection configuration of the ABB Ekip Dip trip unit. It provides long-time (L) overload protection together with selectable short-time delayed (S) or instantaneous (I) short-circuit protection. This allows engineers to select suitable protection characteristics for the electrical distribution system.

What is the difference between an LS/I electronic trip unit and a TMA trip unit?

An LS/I electronic trip unit uses electronic protection technology to provide configurable overload and short-circuit trip characteristics, including selectable short-time or instantaneous protection. A thermal-magnetic adjustable (TMA) trip unit uses thermal and magnetic mechanisms to detect overload and short-circuit conditions. Electronic protection can provide greater flexibility when coordinating protective devices in complex electrical distribution systems.

Where is the ABB EPX-XT5S-E1-4004 typically installed?

The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides protection for high-current outgoing circuits. The ABB XT5S four-pole platform has a nominal width of 190 mm, and additional cableway space may be required for larger conductors. Compatible mounting and connection accessories should be selected for the distribution assembly.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT electronic circuit breakers are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage power distribution. The EPX-XT5S-E1-4004 combines 400 A current capacity, four-pole switching, 50 kA short-circuit protection and advanced Ekip Dip LS/I electronic trip functionality to support reliable and flexible electrical protection in commercial and industrial ABB Protecta Power installations.