ABB EPX-XT5S-TM4004 Protecta Power 400 A four-pole Tmax XT5S moulded case circuit breaker with 50 kA specified breaking capacity and TMA thermal-magnetic protection for compatible low-voltage electrical distribution assemblies.
£1,881.25
The ABB EPX-XT5S-TM4004 is a 400 A, four-pole moulded case circuit breaker (MCCB) designed for low-voltage electrical distribution applications requiring reliable overload and short-circuit protection. Part of the ABB Tmax XT5S circuit breaker family and the Protecta Power Devices range, this MCCB combines a substantial current rating with a 50 kA breaking capacity and thermal-magnetic protection.
Featuring a TMA thermal-magnetic trip unit, the EPX-XT5S-TM4004 provides protection against sustained overload conditions and short-circuit faults. Its thermal protection element responds to excessive current over time, while the magnetic element provides rapid tripping during high fault current conditions. This combination makes the device suitable for protecting distribution circuits, electrical conductors and connected equipment in appropriately designed installations.
The four-pole configuration makes the EPX-XT5S-TM4004 suitable for three-phase distribution arrangements requiring a fourth switched pole. Its 400 A rated current and XT5S frame construction support integration into compatible ABB Protecta Power distribution assemblies, providing a practical solution for commercial and industrial electrical infrastructure.
The ABB EPX-XT5S-TM4004 provides circuit protection for low-voltage distribution systems operating at currents up to its specified 400 A rating. The TMA trip unit combines thermal protection against prolonged overloads with magnetic protection against short-circuit faults. These complementary functions help limit the effects of overcurrent conditions on cables, distribution equipment and connected electrical loads.
Its four-pole configuration is particularly relevant where the electrical design requires a fourth switched conductor alongside the three phases. The 50 kA breaking capacity provides a significant short-circuit protection capability, although the applicable rating must be confirmed at the installation voltage. Designers and installers should also verify conductor sizing, protective coordination, neutral-pole requirements, terminal arrangements and compatibility with the intended ABB Protecta Power assembly.
| Product model | EPX-XT5S-TM4004 |
|---|---|
| ABB order code | 1SDX248644R1 |
| Product group | Protecta Power Devices |
| Circuit breaker series | Tmax XT |
| Circuit breaker family | XT5S |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 400 A |
| Number of poles | 4 |
| Specified breaking capacity | 50 kA |
| Trip unit designation | TMA |
| Protection technology | Thermal-magnetic |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Operating mechanism | Manual circuit breaker operation |
| Electrical system | Low-voltage distribution |
| Distribution arrangement | Four-pole, three-phase applications |
| Installation | Compatible ABB Protecta Power distribution assembly |
| Primary application | Overload and short-circuit protection |
The ABB EPX-XT5S-TM4004 is a 400 A four-pole moulded case circuit breaker designed to provide overload and short-circuit protection in compatible ABB Protecta Power low-voltage electrical distribution assemblies.
The EPX-XT5S-TM4004 has a 400 A rated current and a specified 50 kA breaking capacity. The applicable short-circuit rating should be verified against the operating voltage and prospective fault current of the installation.
TMA identifies the thermal-magnetic trip unit configuration. Thermal protection responds to sustained overload currents, while magnetic protection responds to short-circuit faults. The precise trip settings and adjustment ranges should be confirmed from the applicable ABB technical documentation.
The four-pole configuration allows the circuit breaker to switch four conductors together, making it suitable for appropriately designed three-phase distribution systems requiring a fourth switched pole. The installation design must establish whether the fourth pole is suitable for the intended neutral arrangement.
Both are 400 A ABB XT5S thermal-magnetic MCCBs with a specified 50 kA breaking capacity. The EPX-XT5S-TM4004 has four poles, while the EPX-XT5S-TM4003 has three poles. The correct version depends on the number of conductors that must be switched and the requirements of the electrical distribution system.
ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical contractors, engineers and panel builders with established solutions for low-voltage electrical protection. The EPX-XT5S-TM4004 combines a 400 A current rating, four-pole construction, 50 kA breaking capacity and TMA thermal-magnetic protection to support dependable electrical distribution in commercial and industrial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.