1SDX248633R1 ABB EPX-XT5S-E2-6303 Protecta Power XT5S 630A 3-Pole 50kA MCCB with Ekip Dip LSI Protection

1SDX248633R1 ABB EPX-XT5S-E2-6303 Protecta Power XT5S 630A 3-Pole 50kA MCCB with Ekip Dip LSI Protection

ABB EPX-XT5S-E2-6303 Protecta Power 630 A three-pole Tmax XT5S moulded case circuit breaker with 50 kA breaking capacity, Ekip Dip LSI electronic protection and load side connector configuration for compatible low-voltage electrical distribution assemblies.

SKU: 1SDX248633R1Alt SKU: EPX-XT5S-E2-6303MPN: 1SDX248633R1
Price
List Price £2,780.84 ex VAT
Your Price (ex VAT)
£2,780.84
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,780.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,780.84

Why Choose the ABB EPX-XT5S-E2-6303 630A 3-Pole 50kA MCCB with LSI Protection?

The ABB EPX-XT5S-E2-6303 is a high-performance 630 A, three-pole moulded case circuit breaker (MCCB) designed for demanding low-voltage power distribution applications. Part of the ABB Tmax XT5S range and configured for ABB Protecta Power distribution assemblies, this circuit breaker combines a 50 kA breaking capacity with electronic LSI protection to provide effective overload, short-circuit and short-time fault protection.

Equipped with an ABB Ekip Dip LSI electronic trip unit, the EPX-XT5S-E2-6303 offers three essential protection functions: long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I). These functions support coordinated circuit protection and allow electrical designers to configure suitable protective settings for the installation.

The 630 A rated current, three-pole construction and XT5S 630 frame make this MCCB suitable for substantial three-phase distribution loads. Supplied in a Protecta Power configuration with an LSC load side connector, it supports integration into compatible ABB distribution assemblies, providing a practical protective solution for main distribution circuits, sub-distribution systems and industrial electrical infrastructure.

Key Advantages

  • 630 A rated current for high-capacity low-voltage power distribution.
  • Three-pole construction provides protection across three-phase electrical circuits.
  • 50 kA breaking capacity for applications with significant prospective short-circuit currents, subject to the applicable voltage rating.
  • Electronic LSI protection combines long-time, short-time and instantaneous protective functions.
  • ABB Ekip Dip trip technology provides configurable electronic protection settings.
  • ABB Tmax XT5S platform delivers advanced circuit protection for commercial and industrial installations.
  • Protecta Power configuration supports integration into compatible ABB distribution assemblies.
  • Load side connector arrangement simplifies integration with the designated distribution system.
  • Suitable for electrical distribution projects requiring coordinated protection and dependable circuit isolation.

Key Features

  • ABB Protecta Power Devices range.
  • ABB Tmax XT5S 630 MCCB platform.
  • 630 A rated current.
  • Three-pole circuit breaker configuration.
  • 50 kA breaking capacity in the specified Protecta Power configuration.
  • Ekip Dip LSI electronic trip unit.
  • Long-time protection (L): responds to sustained overload conditions.
  • Short-time protection (S): provides short-circuit protection with intentional delay for coordination.
  • Instantaneous protection (I): responds rapidly to high short-circuit currents.
  • Electronic trip settings support protection coordination within the distribution system.
  • Fixed circuit breaker configuration for compatible electrical distribution assemblies.
  • Front-terminal arrangement identified by the manufacturer's F F designation.
  • LSC load side connector for ABB Protecta Power integration.
  • Manual switching, circuit isolation and resetting after protective operation.
  • ABB manufacturer order code 1SDX248633R1.

Advanced Electronic Protection for Three-Phase Power Distribution

The ABB EPX-XT5S-E2-6303 is designed to protect high-current three-phase distribution circuits against overloads and short-circuit faults. Its Ekip Dip LSI electronic trip unit provides long-time protection against sustained overloads, short-time protection to support selective coordination with downstream protective devices, and instantaneous protection against severe short-circuit conditions. These functions help maintain electrical safety while reducing the likelihood of unnecessary interruption to unaffected circuits when the protection system is correctly coordinated.

The ABB Tmax XT5S 630 platform combines a substantial 630 A current rating with a 50 kA breaking capacity for suitable low-voltage distribution applications. The Protecta Power configuration incorporates a load side connector arrangement for integration into compatible ABB distribution equipment. Electrical designers should verify operating voltage, prospective short-circuit current, trip settings, discrimination requirements, conductor sizing and assembly compatibility before installation.

Typical Applications

  • ABB Protecta Power low-voltage distribution assemblies.
  • Main distribution boards and sub-main electrical distribution.
  • Commercial and industrial three-phase power systems.
  • High-current outgoing feeder protection.
  • Manufacturing facilities and industrial production plants.
  • Large commercial buildings, warehouses and logistics centres.
  • Electrical plant rooms and building services infrastructure.
  • Industrial machinery distribution and motor control centre supply circuits.
  • Electrical distribution systems requiring 630 A three-pole MCCB protection with electronic LSI functionality.

Technical Specifications

Product range Protecta Power Devices
Circuit breaker series Tmax XT
Circuit breaker model XT5S 630
Product model EPX-XT5S-E2-6303
ABB order code 1SDX248633R1
Product type Electronic moulded case circuit breaker
Rated current 630 A
Electronic trip unit rated current 630 A
Number of poles 3
Breaking capacity 50 kA, subject to the applicable operating voltage
Circuit breaker frame XT5S 630
Trip unit Ekip Dip LSI
Protection technology Electronic
Protection functions L, S and I
Long-time protection L – overload protection
Short-time protection S – delayed short-circuit protection
Instantaneous protection I – instantaneous short-circuit protection
Mounting configuration Fixed
Terminal arrangement Front terminals, F F
Connector configuration LSC load side connector
Distribution assembly ABB Protecta Power IV compatible configuration
Electrical system Three-phase low-voltage distribution
Product group Protecta Power Devices
Application Main and sub-distribution circuit protection

Frequently Asked Questions

What is the ABB EPX-XT5S-E2-6303 used for?

The ABB EPX-XT5S-E2-6303 is a 630 A three-pole electronic moulded case circuit breaker designed to protect high-current, three-phase outgoing circuits within compatible ABB Protecta Power low-voltage distribution assemblies.

What is the current rating and breaking capacity of the EPX-XT5S-E2-6303?

The EPX-XT5S-E2-6303 has a 630 A rated current and a specified 50 kA breaking capacity. The applicable short-circuit breaking capacity must be verified against the operating voltage and prospective fault current of the installation.

What does LSI protection mean on this ABB MCCB?

LSI stands for Long-time, Short-time and Instantaneous protection. Long-time protection responds to sustained overloads, short-time protection provides delayed short-circuit protection for coordination, and instantaneous protection responds rapidly to high fault currents.

Does the EPX-XT5S-E2-6303 use an electronic trip unit?

Yes. The EPX-XT5S-E2-6303 incorporates an ABB Ekip Dip LSI electronic trip unit rated at 630 A. Electronic protection enables configurable protective settings to support the requirements of the electrical distribution system.

What is the difference between the EPX-XT5S-E2-6303 and EPX-XT5S-E1-6303?

Both models are 630 A, three-pole, 50 kA ABB XT5S moulded case circuit breakers for compatible Protecta Power assemblies. The EPX-XT5S-E2-6303 provides LSI protection, including a short-time protective function, whereas the EPX-XT5S-E1-6303 is designated LS/I. The appropriate version depends on the required protection functions and coordination study.

Trusted by Electrical Contractors and Panel Builders

ABB Tmax XT circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with advanced solutions for low-voltage electrical protection. The EPX-XT5S-E2-6303 combines a 630 A three-pole configuration, 50 kA breaking capacity and Ekip Dip LSI electronic protection to support reliable circuit protection and coordinated power distribution in demanding commercial and industrial installations.