ABB EPX-XT5S-TM6303 is a 630 A three-pole Tmax XT5S moulded case circuit breaker with a 50 kA breaking-capacity classification and adjustable TMA thermal-magnetic overload and short-circuit protection for compatible Protecta Power low-voltage distribution assemblies.

SKU: 1SDX248631R1Alt SKU: EPX-XT5S-TM6303MPN: 1SDX248631R1
Price
List Price £2,085.44 ex VAT
Your Price (ex VAT)
£2,085.44
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,085.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,085.44

ABB EPX-XT5S-TM6303 630A 3-Pole 50kA Thermal-Magnetic MCCB

The ABB EPX-XT5S-TM6303 is a high-performance 630 A, three-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT5S range, designed for compatible ABB Protecta Power low-voltage electrical distribution assemblies. Featuring a 50 kA breaking-capacity classification and an adjustable TMA thermal-magnetic trip unit, this circuit breaker provides dependable overload and short-circuit protection for demanding commercial and industrial installations.

Built around the ABB Tmax XT5S 630 circuit breaker platform, the EPX-XT5S-TM6303 combines a 630 A rated current with three-pole switching and adjustable protection characteristics. Its thermal-magnetic release responds to sustained overload conditions and high short-circuit currents, helping protect electrical conductors, distribution equipment and connected installations.

The TMA trip unit provides adjustable thermal overload protection and magnetic short-circuit protection. For the corresponding ABB XT5S 630 TMA configuration, the thermal setting range is 252–630 A, while the instantaneous magnetic setting range is 3150–6300 A. These adjustments allow electrical engineers to configure the protective response according to the installation's operating conditions and coordination requirements.

Identified by ABB order code 1SDX248631R1, the EPX-XT5S-TM6303 forms part of the ABB Protecta Power Devices range. It provides a manufacturer-specified 630 A outgoing MCCB option for compatible distribution panelboards requiring substantial current capacity, adjustable thermal-magnetic protection and a 50 kA fault-interruption classification.

Key Advantages

  • 630 A rated current: Suitable for high-capacity low-voltage electrical distribution circuits.
  • 50 kA breaking-capacity classification: Provides substantial short-circuit interruption capability at the manufacturer's specified operating voltage.
  • Three-pole construction: Supports coordinated switching and protection of three-phase circuits.
  • ABB Tmax XT5S technology: Uses ABB's established SACE Tmax XT moulded case circuit breaker platform.
  • Adjustable TMA protection: Allows thermal overload and magnetic short-circuit settings to be configured for the application.
  • Thermal adjustment range: Supports overload setting adjustment from 252–630 A on the corresponding XT5S 630 TMA breaker.
  • Magnetic adjustment range: Provides instantaneous short-circuit setting adjustment from 3150–6300 A.
  • Protecta Power compatibility: Designed for integration into suitable ABB Protecta Power distribution assemblies.
  • Mechanical switching: Provides manual circuit isolation and switching through the MCCB operating mechanism.
  • Professional distribution protection: Supports electrical contractors and panel builders working on high-current commercial and industrial installations.

Key Features

  • ABB EPX-XT5S-TM6303 moulded case circuit breaker.
  • 630 A rated current.
  • Three-pole (3P) configuration.
  • 50 kA Protecta Power breaking-capacity classification.
  • ABB SACE Tmax XT5S circuit breaker platform.
  • XT5S 630 frame configuration.
  • TMA adjustable thermal-magnetic trip unit.
  • Thermal overload protection with adjustable current setting.
  • Magnetic short-circuit protection with adjustable instantaneous threshold.
  • Thermal setting range of 252–630 A for the corresponding XT5S 630 TMA device.
  • Magnetic setting range of 3150–6300 A for the corresponding XT5S 630 TMA device.
  • Manual switching and reset operation.
  • Fixed circuit breaker configuration in the corresponding ABB XT5S 630 TMA product.
  • Front terminal connection arrangement in the corresponding ABB breaker configuration.
  • Designed for compatible ABB Protecta Power outgoing circuit installations.
  • Part of the ABB Protecta Power Devices product range.

Reliable 630A Circuit Protection with ABB Tmax XT5S Technology

High-current electrical distribution systems require protective devices capable of responding effectively to overloads and short-circuit faults. The ABB EPX-XT5S-TM6303 combines the ABB Tmax XT5S circuit breaker platform with an adjustable thermal-magnetic trip unit, supporting reliable protection of appropriately designed commercial and industrial distribution circuits.

The thermal protection function responds to sustained overload currents that could otherwise produce excessive heating in electrical conductors and connected equipment. On the corresponding ABB XT5S 630 TMA breaker, the thermal setting can be adjusted within a range of 252–630 A. This allows the protection setting to be coordinated with the cable current-carrying capacity and the intended operating load.

The magnetic protection function responds to high short-circuit currents. Its adjustable instantaneous operating threshold, specified as 3150–6300 A on the corresponding XT5S 630 TMA configuration, allows the short-circuit response to be selected according to the requirements of the installation.

Unlike electronic trip units, the TMA thermal-magnetic release provides protection through thermal and magnetic operating elements. This makes it a practical choice for installations where adjustable overload and instantaneous short-circuit protection are required without additional electronic monitoring functions.

The three-pole configuration provides coordinated switching and protection of the three phase conductors. It is suitable for appropriately designed three-phase electrical distribution circuits, with any neutral conductor arrangement addressed separately according to the electrical system design.

The 50 kA breaking-capacity classification is an important consideration when specifying protection for distribution systems with substantial prospective fault currents. The actual interrupting capability must be confirmed at the installation's rated operating voltage, and the device must be selected to satisfy the applicable short-circuit protection requirements.

For installation within the ABB Protecta Power system, the EPX-XT5S-TM6303 must be matched with the appropriate panelboard mounting and connection arrangements. ABB advises that a side cableway extension box may be considered for XT5 outgoing devices where larger cables require additional installation space.

Electrical designers should also verify conductor sizes, terminal compatibility, protective coordination, ambient temperature and the thermal performance of the completed assembly. The corresponding ABB XT5S 630 TMA breaker uses a fixed configuration with front terminals, but the supplied Protecta Power arrangement should be checked before installation.

With its substantial current rating, adjustable thermal-magnetic protection and ABB Tmax XT5S construction, the EPX-XT5S-TM6303 provides a practical solution for high-capacity outgoing circuit protection in professionally assembled low-voltage distribution systems.

Typical Applications

  • ABB Protecta Power outgoing circuit protection.
  • 630 A three-phase electrical distribution circuits.
  • Commercial low-voltage distribution panelboards.
  • Industrial electrical switchgear assemblies.
  • Manufacturing plants and production facilities.
  • Warehouses and logistics distribution centres.
  • Large office buildings and commercial developments.
  • Mechanical and electrical building services distribution.
  • Industrial machinery distribution feeders.
  • Sub-main electrical distribution circuits.
  • Distribution board refurbishment and upgrades.
  • Electrical panel building and switchgear assembly projects.
  • Installations requiring adjustable thermal-magnetic overload and short-circuit protection.

Technical Specifications

Product group Protecta Power Devices
Product model EPX-XT5S-TM6303
ABB order code 1SDX248631R1
Product type Moulded case circuit breaker (MCCB)
Circuit breaker range ABB SACE Tmax XT
Circuit breaker family XT5S
Frame configuration XT5S 630
Rated current 630 A
Number of poles 3
Pole configuration Three-pole (3P)
Breaking-capacity classification 50 kA, subject to the applicable operating voltage and ABB technical data
Trip unit TMA
Trip technology Adjustable thermal-magnetic
Overload protection Thermal
Short-circuit protection Magnetic
Thermal adjustment range 252–630 A for the corresponding XT5S 630 TMA breaker
Instantaneous magnetic adjustment range 3150–6300 A for the corresponding XT5S 630 TMA breaker
Operating mechanism Manual toggle operation
Installation configuration Fixed in the corresponding XT5S 630 TMA breaker
Terminal arrangement Front terminals in the corresponding XT5S 630 TMA breaker
Applicable circuit breaker standard IEC 60947-2
Compatible distribution system ABB Protecta Power
Related 400 A three-pole model EPX-XT5S-TM4003
Related 630 A four-pole model EPX-XT5S-TM6304
Related 630 A electronic LS/I model EPX-XT5S-E1-6303
Related 630 A electronic LSI model EPX-XT5S-E2-6303
Application High-capacity outgoing circuit protection in compatible low-voltage distribution assemblies

Frequently Asked Questions

What is the ABB EPX-XT5S-TM6303 used for?

The ABB EPX-XT5S-TM6303 is a 630 A three-pole thermal-magnetic MCCB designed for high-capacity outgoing circuit protection in compatible ABB Protecta Power low-voltage distribution assemblies.

What is the rated current of the EPX-XT5S-TM6303?

The EPX-XT5S-TM6303 has a rated current of 630 A and uses the ABB Tmax XT5S 630 circuit breaker platform.

What is the breaking capacity of the EPX-XT5S-TM6303?

The EPX-XT5S-TM6303 is specified with a 50 kA breaking-capacity classification in the ABB Protecta Power range. The applicable breaking capacity must be verified at the installation's operating voltage.

Is the EPX-XT5S-TM6303 a three-pole circuit breaker?

Yes. The EPX-XT5S-TM6303 is a three-pole (3P) MCCB designed to protect and switch three phase conductors in suitable low-voltage electrical distribution systems.

What does TMA mean on the ABB EPX-XT5S-TM6303?

TMA identifies an adjustable thermal-magnetic trip unit. It provides thermal overload protection and magnetic short-circuit protection, with adjustable settings on the corresponding ABB XT5S 630 TMA breaker.

What is the thermal adjustment range of the XT5S 630 TMA breaker?

The corresponding ABB XT5S 630 TMA breaker provides a thermal adjustment range of 252–630 A. The selected setting must be coordinated with the connected conductors and installation requirements.

What is the magnetic adjustment range of the XT5S 630 TMA breaker?

The corresponding ABB XT5S 630 TMA breaker has an instantaneous magnetic adjustment range of 3150–6300 A. The setting must be selected according to the installation's fault conditions and protection coordination requirements.

What is the difference between EPX-XT5S-TM6303 and EPX-XT5S-E1-6303?

The EPX-XT5S-TM6303 uses adjustable TMA thermal-magnetic protection, while the EPX-XT5S-E1-6303 is the corresponding 630 A three-pole XT5S model with electronic LS/I protection.

Can the EPX-XT5S-TM6303 be used in ABB Protecta Power panelboards?

Yes. The EPX-XT5S-TM6303 belongs to the ABB Protecta Power Devices range and is intended for compatible low-voltage distribution assemblies. The appropriate panelboard mounting, connection and cable accommodation arrangements must be confirmed before installation.

Trusted by Electrical Contractors and Panel Builders

ABB Protecta Power moulded case circuit breakers provide a coordinated solution for demanding electrical distribution applications. The EPX-XT5S-TM6303 combines a 630 A rating, three-pole Tmax XT5S construction, 50 kA breaking-capacity classification and adjustable TMA protection, supporting professional electrical contractors and panel builders in delivering dependable low-voltage distribution assemblies.