ABB EPX-XT5S-E1-4003 Protecta Power 400 A three-pole 50 kA electronic-trip moulded case circuit breaker with Ekip LS/I protection, based on the ABB SACE Tmax XT5S platform, order code 1SDX248629R1, for compatible low-voltage electrical distribution installations.
£1,507.13
The ABB EPX-XT5S-E1-4003 is a 400 A three-pole moulded case circuit breaker (MCCB) designed for outgoing circuit protection within compatible ABB Protecta Power low-voltage distribution assemblies. Built around the ABB SACE Tmax XT5S circuit breaker platform, this device combines a 50 kA specified breaking capacity with an electronic Ekip LS/I trip unit, providing configurable overload and short-circuit protection for appropriately designed three-phase electrical circuits.
Part of the ABB Protecta Power Devices product group, the EPX-XT5S-E1-4003 is identified by ABB order code 1SDX248629R1. Its manufacturer product description is EPX-XT5S-E1-4003 400A 3P 50kA MCCB -LS/I. The device is intended for installations requiring a 400 A three-pole outgoing circuit breaker with electronic protection characteristics rather than a conventional thermal-magnetic trip unit.
ABB's Protecta Power selection information places the EPX-XT5S-E1-4003 in its three-pole, 50 kA electronic-trip MCCB range. The LS/I designation identifies an electronic protection arrangement providing long-time overload protection (L), with selection between short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I), subject to the capabilities and settings of the supplied trip unit. This makes the device relevant to distribution systems where protection adjustment and coordination are important design considerations.
The ABB EPX-XT5S-E1-4003 uses an electronic Ekip trip unit to provide protection against overload and short-circuit conditions. Unlike a conventional thermal-magnetic MCCB, an electronic-trip device uses electronic current measurement and processing to determine when the applicable protection thresholds have been reached.
The L protection function provides long-time overload protection. It is intended to respond to sustained overcurrent conditions that could otherwise cause excessive heating of cables and connected electrical equipment. The relevant current threshold and operating characteristics must be selected in accordance with the circuit design and the adjustment facilities available on the supplied trip unit.
The S protection function provides short-time delayed short-circuit protection. Where supported and selected, a short intentional delay may assist with protection coordination between upstream and downstream devices. The suitability of any delay depends on the fault withstand capability of the electrical installation and the results of the protection coordination study.
The I protection function provides instantaneous short-circuit protection. It is intended to respond rapidly when fault current reaches the applicable operating threshold. ABB describes its Ekip LS/I arrangement as providing L protection with a choice between S and I protection. It should therefore not be assumed that the EPX-XT5S-E1-4003 provides independently adjustable L, S and I functions simultaneously; ABB identifies that broader arrangement as Ekip LSI.
The exact settings, adjustment increments, operating curves and available functions depend on the supplied Ekip trip-unit configuration. These details must be checked against the applicable ABB documentation before commissioning. Electronic protection should be configured by a suitably competent person using the electrical design and the relevant protection coordination requirements.
The EPX-XT5S-E1-4003 has a manufacturer-specified 50 kA breaking capacity. This is a key consideration when selecting an MCCB for a low-voltage distribution system, particularly where the prospective short-circuit current may be significant.
A circuit breaker must be capable of safely interrupting the fault current expected at its installation point. The stated 50 kA rating must be considered alongside the applicable operating voltage and the manufacturer's published interruption ratings. In particular, the relevant ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics) should be confirmed for the intended electrical system.
The three-pole configuration provides coordinated switching and protection of three phase conductors. This makes the device suitable for appropriately designed three-phase distribution circuits, including submains, downstream distribution assemblies and industrial electrical loads.
The EPX-XT5S-E1-4003 is a three-pole MCCB, not a four-pole device. Where the electrical design requires a four-pole configuration, ABB offers the separately specified EPX-XT5S-E1-4004. The appropriate pole arrangement must be selected according to the system earthing arrangement, neutral conductor requirements and applicable installation standards.
The ABB Protecta Power system provides a coordinated range of low-voltage distribution assemblies, protective devices and installation accessories. The EPX-XT5S-E1-4003 is listed as a compatible outgoing MCCB option within ABB's Protecta Power selection information.
ABB identifies a 140 mm nominal width for the XT5S three-pole outgoing device range in its Protecta Power selection guide. This value is useful for understanding the panelboard selection arrangement, but it should not be treated as the complete installed dimensions of the MCCB and all associated connection components.
For XT5 outgoing devices, ABB advises considering a side cableway extension box where larger cables require additional installation space. At a nominal current of 400 A, conductor routing, cable bending radius and termination access can have a significant influence on the distribution assembly layout.
The actual cable size must be established from the electrical design, taking account of current-carrying capacity, conductor material, installation method, ambient conditions, grouping factors, voltage drop and short-circuit withstand requirements. Terminal compatibility must also be verified against the selected ABB connection arrangement.
The appropriate MCCB mounting, connection and cover accessories must be selected for the intended Protecta Power panelboard. The exact scope of supply under order code 1SDX248629R1 should be confirmed before ordering. A complete panelboard, side cableway extension or additional installation accessories should not be assumed to be included unless expressly specified.
ABB offers both electronic and thermal-magnetic circuit breaker options within the XT5S range. The EPX-XT5S-E1-4003 is the 400 A three-pole electronic LS/I version, while the EPX-XT5S-TM4003 is a corresponding 400 A three-pole thermal-magnetic TMA version.
The principal distinction is the protection technology. A TMA circuit breaker uses thermal and magnetic operating elements, whereas an Ekip electronic-trip MCCB uses electronic protection processing and offers the settings associated with its specified trip-unit functions.
The LS/I version may be preferred where the electrical design requires electronic protection characteristics or coordination flexibility. However, it must not be confused with a full LSI electronic trip unit, which provides all three L, S and I protection characteristics as separately available functions according to the applicable ABB configuration.
ABB also lists related products such as the EPX-XT5S-E1-6303, a 630 A three-pole electronic LS/I MCCB, and the EPX-XT5S-E1-4004, a 400 A four-pole electronic LS/I MCCB. These are distinct devices and should not be substituted without checking the circuit rating, pole configuration, protection requirements and panelboard compatibility.
| Product group | Protecta Power Devices |
|---|---|
| Series | Protecta Power |
| ABB order code | 1SDX248629R1 |
| Manufacturer product description | EPX-XT5S-E1-4003 400A 3P 50kA MCCB -LS/I |
| Product type | Electronic-trip moulded case circuit breaker |
| Product category | Low-voltage circuit protection devices |
| Circuit breaker family | ABB SACE Tmax XT |
| Device platform | XT5S |
| Frame family | XT5 |
| Breaking-capacity class | S |
| Rated current | 400 A |
| Number of poles | 3 |
| Pole configuration | 3P |
| Specified breaking capacity | 50 kA |
| Protection technology | Electronic |
| Trip-unit family | ABB Ekip |
| Trip-unit designation | LS/I |
| Overload protection | L — long-time protection |
| Short-circuit protection | S or I — selectable according to the supplied trip-unit configuration |
| Nominal width listed for XT5S three-pole outgoing devices | 140 mm |
| Primary application | Three-phase low-voltage circuit protection |
| Associated distribution system | ABB Protecta Power |
| Typical installation position | Compatible outgoing MCCB arrangement |
| Operating voltage | Refer to ABB technical documentation |
| Applicable Icu and Ics ratings | Verify at the intended operating voltage |
| Electronic trip adjustment ranges | Confirm from the supplied Ekip trip-unit documentation |
| Terminal configuration | Confirm against the supplied device and connection accessories |
| Maximum conductor capacity | Dependent on the selected terminal arrangement |
| Mounting accessories | Select according to the Protecta Power assembly |
| Related thermal-magnetic variant | EPX-XT5S-TM4003 |
| Related four-pole electronic variant | EPX-XT5S-E1-4004 |
| Related 630 A electronic variant | EPX-XT5S-E1-6303 |
The ABB EPX-XT5S-E1-4003 is a 400 A three-pole electronic-trip MCCB designed for compatible ABB Protecta Power low-voltage distribution installations. It provides overload and short-circuit protection through an Ekip LS/I electronic trip arrangement.
The EPX-XT5S-E1-4003 has a manufacturer-specified 50 kA breaking capacity. The applicable interruption rating must be verified at the intended operating voltage using ABB's technical documentation, together with the prospective short-circuit current at the installation point.
LS/I identifies an electronic protection arrangement providing L long-time overload protection with a choice between S short-time delayed short-circuit protection and I instantaneous short-circuit protection. ABB distinguishes LS/I from LSI, which provides all three protection characteristics. The available settings must be confirmed from the supplied Ekip trip-unit documentation.
Both products are 400 A three-pole 50 kA XT5S MCCBs. The EPX-XT5S-E1-4003 uses an electronic Ekip LS/I trip unit, while the EPX-XT5S-TM4003 uses a thermal-magnetic TMA trip unit. The correct version depends on the required protection characteristics and electrical coordination design.
The ABB order code is 1SDX248629R1, and the model reference is EPX-XT5S-E1-4003. The manufacturer product description is EPX-XT5S-E1-4003 400A 3P 50kA MCCB -LS/I, within the ABB Protecta Power Devices product group.
ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage protective devices, distribution assemblies and installation accessories. The EPX-XT5S-E1-4003 combines a 400 A three-pole ABB SACE Tmax XT5S circuit breaker with 50 kA specified breaking capacity and electronic Ekip LS/I protection, supporting configurable outgoing circuit protection within compatible Protecta Power installations.