1SDX248628R1 ABB EPX-XT5S-TM4003 Protecta Power 400A 3-Pole 50kA MCCB with TMA Thermal-Magnetic Trip

1SDX248628R1 ABB EPX-XT5S-TM4003 Protecta Power 400A 3-Pole 50kA MCCB with TMA Thermal-Magnetic Trip

ABB EPX-XT5S-TM4003 Protecta Power 400 A three-pole 50 kA moulded case circuit breaker with thermal-magnetic TMA protection, based on the ABB SACE Tmax XT5S platform, order code 1SDX248628R1, for compatible low-voltage electrical distribution installations.

SKU: 1SDX248628R1Alt SKU: EPX-XT5S-TM4003MPN: 1SDX248628R1
Price
List Price £1,416.50 ex VAT
Your Price (ex VAT)
£1,416.50
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,416.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,416.50

Why Choose the ABB EPX-XT5S-TM4003 400A 3-Pole MCCB?

The ABB EPX-XT5S-TM4003 is a 400 A three-pole moulded case circuit breaker (MCCB) designed for low-voltage circuit protection within compatible ABB Protecta Power electrical distribution assemblies. Based on the ABB SACE Tmax XT5S circuit breaker platform, this device combines a 50 kA breaking capacity with a thermal-magnetic (TMA) trip unit to provide overload and short-circuit protection for appropriately designed three-phase electrical circuits.

Part of the ABB Protecta Power Devices product group, the EPX-XT5S-TM4003 is identified by ABB order code 1SDX248628R1. Its manufacturer product description is EPX-XT5S-TM4003 400A 3P 50kA MCCB - TMA. The device is intended for installations requiring a manufacturer-specified 400 A three-pole protective device within the ABB Protecta Power distribution system.

The XT5S platform belongs to ABB's SACE Tmax XT range of moulded case circuit breakers. The 400 A rating identifies the nominal current of this device, while the three-pole configuration provides coordinated switching and protection of three phase conductors. Its 50 kA breaking capacity makes it suitable for applications where the prospective short-circuit current requires an appropriately rated protective device, subject to verification of the applicable operating voltage and installation conditions.

Key Advantages

  • 400 A rated current for appropriately designed higher-current distribution circuits.
  • Three-pole (3P) configuration for coordinated protection of three phase conductors.
  • 50 kA breaking capacity as specified in the ABB manufacturer product description.
  • Uses the established ABB SACE Tmax XT5S moulded case circuit breaker platform.
  • Thermal-magnetic TMA protection against overload and short-circuit conditions.
  • Suitable for compatible ABB Protecta Power electrical distribution assemblies.
  • Provides a manufacturer-defined MCCB option for commercial and industrial low-voltage installations.
  • Supports the design of distribution systems requiring three-phase circuit protection.
  • Offers thermal-magnetic protection without requiring an electronic trip unit.
  • Forms part of ABB's wider range of XT5 outgoing circuit breaker options.
  • Available alongside alternative XT5 devices with electronic protection functions.
  • Suitable for panel-building projects where the circuit breaker and installation accessories are selected as a coordinated system.
  • Clearly identified by ABB order code 1SDX248628R1 for accurate specification and procurement.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-XT5S-TM4003 manufacturer model reference.
  • 400 A nominal rated current.
  • Three-pole (3P) circuit breaker configuration.
  • 50 kA specified breaking capacity.
  • ABB SACE Tmax XT5S circuit breaker platform.
  • XT5 frame family.
  • S breaking-capacity performance class.
  • Thermal-magnetic trip technology.
  • TMA trip-unit designation.
  • Thermal response to sustained overload conditions.
  • Magnetic response to short-circuit fault conditions.
  • Common three-pole switching arrangement.
  • Designed for low-voltage electrical distribution applications.
  • Suitable for compatible Protecta Power outgoing MCCB installations.
  • Can be specified with the appropriate ABB mounting, connection and protective-cover accessories.
  • ABB recommends considering a side cableway extension box for XT5 outgoing devices where larger cables require additional installation space.
  • Distinct from XT5 electronic-trip variants offering LS/I or LSI protection functions.
  • ABB order code 1SDX248628R1.

400A Thermal-Magnetic Protection with 50kA Breaking Capacity

The ABB EPX-XT5S-TM4003 provides three-pole circuit protection using a thermal-magnetic TMA trip unit. Thermal-magnetic MCCBs combine two complementary operating principles to respond to different types of electrical overcurrent. The thermal element provides protection against sustained overload conditions, while the magnetic element responds to the substantially higher currents associated with short-circuit faults.

The thermal protection element is intended to respond when current remains above the relevant operating threshold for a sufficient period. Its time-dependent response helps distinguish sustained overload conditions from normal short-duration variations in circuit loading. The precise operating characteristics depend on the installed trip unit and its documented settings.

The magnetic protection element responds to short-circuit current conditions. Magnetic protection is important because high fault currents can cause severe thermal and mechanical stresses within electrical distribution equipment. The selected MCCB must be capable of interrupting the prospective fault current at its installation point and must be appropriately coordinated with the remainder of the protection system.

The EPX-XT5S-TM4003 is specified as a 50 kA MCCB. This rating should not be considered independently of the operating voltage or applicable interruption-rating standard. Circuit breaker breaking capacity can vary according to the electrical system and the rating definition used. The relevant ABB documentation must therefore be consulted to establish the applicable Icu and Ics values for the intended installation.

The manufacturer's TMA designation identifies the thermal-magnetic protection arrangement. Exact thermal and magnetic adjustment ranges should be confirmed for the supplied XT5S device before commissioning. Protection settings must be determined through the electrical design and any required discrimination or coordination assessment rather than selected solely from the nominal 400 A rating.

Three-Pole Circuit Protection for Low-Voltage Distribution

The three-pole configuration enables the EPX-XT5S-TM4003 to provide coordinated switching and protection of the three phase conductors in a suitable three-phase electrical system. This makes it relevant to distribution circuits supplying three-phase equipment, downstream distribution assemblies and other appropriately designed electrical loads.

As a 400 A MCCB, the device must be selected with consideration of the circuit design current, conductor current-carrying capacity, installation conditions and prospective fault level. The nominal current rating alone does not determine whether the circuit breaker is suitable for a particular load or cable arrangement.

The device is a three-pole breaker and should not be described as a four-pole protective device. Where the electrical design requires neutral conductor switching or a four-pole configuration, a separately specified compatible product must be selected. ABB lists the related EPX-XT5S-TM4004 as a 400 A four-pole thermal-magnetic MCCB.

The XT5S platform is part of ABB's broader Tmax XT circuit breaker range, which includes devices with different current ratings, breaking-capacity classes and trip technologies. The correct product must be chosen according to the electrical design rather than substituted solely because it belongs to the same frame family.

ABB Protecta Power Installation and Accessory Selection

The EPX-XT5S-TM4003 is intended for integration into compatible ABB Protecta Power electrical distribution arrangements. Correct installation requires confirmation of the panelboard configuration, MCCB mounting provisions, connection components, protective covers and available cable termination space.

ABB's Protecta Power selection guidance notes that, for XT5 outgoing devices, a side cableway extension box should be considered where larger cables require additional space. This is particularly relevant for higher-current outgoing circuits, where conductor size, bending radius and termination access can influence the enclosure layout.

Cable sizing must be determined from the electrical design rather than from the circuit breaker frame size alone. The installation must account for conductor material, current-carrying capacity, installation method, ambient temperature, grouping factors, voltage drop and short-circuit withstand requirements. The selected terminal arrangement must also be suitable for the conductor type and cross-sectional area.

Compatible MCCB mounting and cover accessories should be selected according to the specific Protecta Power assembly. The exact components supplied under order code 1SDX248628R1 should be confirmed from ABB's product documentation and the supplier's scope of supply. A complete distribution panelboard, cableway extension or unrelated connection accessories should not be assumed to be included.

Choosing Between XT5 Thermal-Magnetic and Electronic MCCBs

The EPX-XT5S-TM4003 uses a TMA thermal-magnetic trip unit. This makes it a suitable option where the electrical protection design calls for thermal-magnetic overload and short-circuit protection rather than the additional protection characteristics available from an electronic trip system.

ABB also lists the EPX-XT5S-E1-4003, a 400 A three-pole 50 kA MCCB with an electronic LS/I protection arrangement. Electronic trip technologies can provide alternative adjustment and protection functions, depending on the selected trip unit.

For applications requiring different protection functions or higher nominal current ratings, ABB offers additional XT5 variants, including the EPX-XT5S-TM6303 630 A three-pole thermal-magnetic MCCB and electronic-trip XT5 alternatives. These are separate manufacturer products and should not be treated as direct substitutes without verifying the electrical and mechanical requirements.

Selection between thermal-magnetic and electronic-trip MCCBs should be based on the circuit protection study, required operating characteristics, prospective fault current and any discrimination requirements. The final device selection and protection settings should follow ABB's applicable technical documentation and relevant electrical installation standards.

Typical Applications

  • ABB Protecta Power outgoing circuit protection installations.
  • 400 A three-phase electrical distribution circuits.
  • Commercial building low-voltage distribution panelboards.
  • Industrial electrical distribution systems.
  • Electrical switchrooms and main distribution installations.
  • Submain circuits supplying downstream distribution assemblies.
  • Three-phase plant and equipment distribution circuits.
  • Electrical installations requiring an appropriately rated 50 kA MCCB.
  • Distribution systems using thermal-magnetic overload and short-circuit protection.
  • Switchboard manufacturing and electrical panel-building projects.
  • Compatible Protecta Power distribution system upgrades and extensions.
  • Replacement of a correctly matched ABB Protecta Power XT5S protective device.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power
ABB order code 1SDX248628R1
Manufacturer product description EPX-XT5S-TM4003 400A 3P 50kA MCCB - TMA
Product type Moulded case circuit breaker
Product category Low-voltage circuit protection devices
Circuit breaker family ABB SACE Tmax XT
Device platform XT5S
Frame family XT5
Breaking-capacity class S
Rated current 400 A
Number of poles 3
Pole configuration 3P
Specified breaking capacity 50 kA
Protection technology Thermal-magnetic
Trip-unit designation TMA
Protection functions Overload and short-circuit protection
Primary application Three-phase low-voltage circuit protection
Associated distribution system ABB Protecta Power
Typical installation position Compatible outgoing MCCB arrangement
Operating voltage and corresponding interruption rating Confirm from the applicable ABB technical documentation
Thermal and magnetic adjustment ranges Confirm for the supplied TMA trip unit
Terminal configuration Confirm against the supplied device and connection accessories
Maximum conductor capacity Dependent on the selected terminal arrangement
Mounting accessories Select according to the Protecta Power assembly
Related 400 A electronic-trip variant EPX-XT5S-E1-4003
Related 630 A thermal-magnetic variant EPX-XT5S-TM6303
Related 400 A four-pole variant EPX-XT5S-TM4004

Frequently Asked Questions

What is the ABB EPX-XT5S-TM4003 used for?

The ABB EPX-XT5S-TM4003 is a 400 A three-pole moulded case circuit breaker designed for compatible ABB Protecta Power low-voltage distribution installations. It provides thermal-magnetic overload and short-circuit protection for appropriately designed three-phase circuits.

What is the breaking capacity of the ABB EPX-XT5S-TM4003?

The EPX-XT5S-TM4003 has a manufacturer-specified 50 kA breaking capacity. The applicable interruption rating must be verified at the intended operating voltage using ABB's technical documentation, together with the prospective short-circuit current at the installation point.

What does TMA mean on the ABB EPX-XT5S-TM4003?

TMA identifies the circuit breaker's thermal-magnetic trip unit. The thermal element provides overload protection, while the magnetic element provides short-circuit protection. The exact adjustment ranges and trip characteristics must be confirmed from the documentation for the supplied device.

Is the EPX-XT5S-TM4003 a three-pole or four-pole MCCB?

The EPX-XT5S-TM4003 is a three-pole (3P) MCCB rated at 400 A. For applications requiring a four-pole configuration, ABB lists the separate EPX-XT5S-TM4004 400 A four-pole thermal-magnetic MCCB. The correct device must be selected according to the electrical system design.

What is the ABB order code for the EPX-XT5S-TM4003?

The ABB order code is 1SDX248628R1, and the model reference is EPX-XT5S-TM4003. The manufacturer product description is EPX-XT5S-TM4003 400A 3P 50kA MCCB - TMA, within the ABB Protecta Power Devices product group.

Trusted ABB Protecta Power Circuit Protection Solutions

ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage circuit breakers, panelboards and installation accessories. The EPX-XT5S-TM4003 combines a 400 A three-pole ABB SACE Tmax XT5S circuit breaker with 50 kA breaking capacity and thermal-magnetic TMA protection, supporting robust outgoing circuit protection within compatible Protecta Power electrical distribution assemblies.