ABB SACE Emax 3 E4.3H 3200 air circuit breaker moving part with Ekip Aware LSIG trip unit, 3200 A rated current and 100 kA breaking capacity at 415 V for low-voltage power distribution systems.
£17,775.47
The ABB 1SDA129015R1 is a high-performance SACE Emax 3 E4.3H 3200 air circuit breaker moving part designed for reliable protection and control of low-voltage electrical distribution systems. As part of the advanced ABB SACE Emax 3 series, this withdrawable circuit breaker component provides dependable protection, monitoring and switching performance for demanding industrial and commercial power applications.
This model is supplied as the moving part only (WMP) of a withdrawable air circuit breaker, with the compatible fixed part ordered separately. The integrated Ekip Aware LSIG trip unit provides comprehensive long-time, short-time, instantaneous and ground-fault protection for electrical distribution installations.
With a 3200 A rated current, 4-pole configuration and 100 kA Icu at 415 V, the ABB SACE Emax 3 E4.3H 3200 is suited to high-capacity low-voltage power distribution applications requiring robust circuit protection and reliable operational performance.
The ABB SACE Emax 3 E4.3H 3200 combines high current-handling capability with an advanced Ekip Aware LSIG trip unit to support dependable protection of high-capacity low-voltage distribution systems. Its LSIG protection functions address long-time, short-time, instantaneous and ground-fault conditions, helping provide comprehensive circuit protection in demanding installations.
As a withdrawable moving part, the 1SDA129015R1 is intended for use with the appropriate SACE Emax 3 fixed part, which is ordered separately. This configuration supports practical maintenance and equipment management while providing the high breaking performance expected from the SACE Emax 3 platform.
Tick the specs you need, then view products that match.
| Trip Unit | LSIG | |
|---|---|---|
| Device Type | ACB | |
| Current | 3200 A | |
| Poles | 4-pole | |
| Phase | Three Phase | |
| Breaking Capacity | 100 kA | |
| Application | Power distribution | |
| Mounting Type | Withdrawable | |
| Manufacturer | ABB | |
| Series | SACE Emax 3 | |
| Model | E4.3H 3200 | |
| Part number | 1SDA129015R1 | |
| Product type | Air circuit breaker moving part | |
| Rated current In | 3200 A | |
| Number of poles | 4-pole | |
| Ultimate short-circuit breaking capacity Icu | 100 kA at 415 V | |
| Trip unit | Ekip Aware LSIG | |
| Installation | Withdrawable | |
| Supplied configuration | Moving part only (WMP) | |
| Fixed part | Ordered separately | |
| HS Code | 85362090 |
ABB 1SDA129015R1 is the moving part of a withdrawable SACE Emax 3 E4.3H 3200 air circuit breaker, designed for protection and switching in high-capacity low-voltage power distribution systems.
The ABB SACE Emax 3 E4.3H 3200 has a rated current In of 3200 A.
The E4.3H 3200 configuration provides an ultimate short-circuit breaking capacity Icu of 100 kA at 415 V.
ABB 1SDA129015R1 is specified with an Ekip Aware LSIG trip unit providing long-time, short-time, instantaneous and ground-fault protection functions.
No. ABB 1SDA129015R1 is the withdrawable moving part only (WMP); the compatible fixed part is ordered separately.
ABB SACE Emax 3 air circuit breakers are widely used by electrical engineers and system designers to deliver dependable protection, intelligent monitoring and reliable performance in modern low-voltage distribution systems.