ABB SACE Emax 3 E4.3S 3200 is a 4-pole 3200 A withdrawable air circuit breaker with an Ekip Aware LSIG trip unit and 85 kA Icu at 415 V, supplied as the moving part only with the fixed part ordered separately.
£16,887.41
The ABB SACE Emax 3 E4.3S 3200 1SDA129014R1 is a high-performance air circuit breaker designed for reliable protection and control in demanding low-voltage power distribution systems. This 4-pole circuit breaker has a rated current of 3200 A and a high short-circuit breaking capacity of 85 kA at 415 V, making it suitable for high-capacity electrical installations.
Equipped with an Ekip Aware LSIG trip unit, the breaker provides comprehensive protection functions covering long-time, short-time, instantaneous and ground-fault conditions. The Ekip Aware platform supports advanced protection and monitoring capabilities for modern power distribution applications.
This is the withdrawable moving part only (WMP) of the ABB SACE Emax 3 E4.3S 3200 air circuit breaker. The corresponding fixed part is ordered separately, allowing the breaker assembly to be configured to suit the installation requirements.
The ABB SACE Emax 3 E4.3S 3200 combines a 3200 A current rating with an 85 kA short-circuit breaking capacity at 415 V to provide robust protection for high-capacity low-voltage distribution systems. Its 4-pole construction makes it suitable for applications where all required poles must be switched and protected.
The Ekip Aware LSIG trip unit provides the core protection functions required for managing overloads, short-circuit conditions and ground faults. With its withdrawable moving-part configuration, the 1SDA129014R1 can be integrated with the separately ordered fixed part to create the required SACE Emax 3 withdrawable installation.
The ABB 1SDA129014R1 is a SACE Emax 3 E4.3S 3200 air circuit breaker with a 3200 A rated current, 4-pole configuration, 85 kA Icu at 415 V and an Ekip Aware LSIG trip unit.
The ABB SACE Emax 3 E4.3S 3200 has a rated current (In) of 3200 A.
The rated ultimate short-circuit breaking capacity (Icu) is 85 kA at 415 V.
The 1SDA129014R1 is specified with an Ekip Aware LSIG trip unit, providing long-time, short-time, instantaneous and ground-fault protection functions.
No. The 1SDA129014R1 is the withdrawable moving part only (WMP). The corresponding fixed part is ordered separately.
Trusted by Power Distribution Professionals Worldwide
ABB SACE Emax 3 air circuit breakers provide high-capacity switching and protection for demanding low-voltage power distribution applications, with advanced trip-unit technology and configurable installation solutions.
Tick the specs you need, then view products that match.
| Trip Unit | LSIG | |
|---|---|---|
| Device Type | ACB | |
| Current | 3200 A | |
| Poles | 4-pole | |
| Phase | Three Phase | |
| Breaking Capacity | 85 kA | |
| Application | Power distribution | |
| Mounting Type | Withdrawable | |
| Manufacturer | ABB | |
| Series | SACE Emax 3 | |
| Frame | E4.3S 3200 | |
| Model | E4.3S 3200 | |
| Product type | Air circuit breaker | |
| Part number | 1SDA129014R1 | |
| Rated current (In) | 3200 A | |
| Rated ultimate short-circuit breaking capacity (Icu) | 85 kA at 415 V | |
| Number of poles | 4 | |
| Trip unit | Ekip Aware LSIG | |
| Protection functions | Long-time, short-time, instantaneous and ground-fault (LSIG) | |
| Installation type | Withdrawable | |
| Supplied configuration | Moving part only (WMP) | |
| Fixed part | Ordered separately | |
| HS Code | 85362090 |