ABB SACE Emax 3 E6.3X 4000 three-pole withdrawable air circuit breaker moving part with Ekip Aware LSIG trip unit, 4000 A rated current and 150 kA Icu at 415 V.
£29,139.69
The ABB 1SDA128968R1 is a high-performance SACE Emax 3 air circuit breaker moving part designed for reliable protection and control of high-current low-voltage electrical distribution systems. Configured as an E6.3X 4000 three-pole withdrawable circuit breaker, it combines a 4000 A rated current with an Ekip Aware LSIG electronic trip unit for comprehensive electrical protection.
This ABB SACE Emax 3 circuit breaker incorporates an Ekip Aware LSIG trip unit providing long-time, short-time, instantaneous and earth-fault protection functions. Its withdrawable construction allows the moving part to be withdrawn from the corresponding fixed installation, supporting practical inspection, maintenance and servicing of industrial switchgear.
With a rated current of 4000 A and a rated ultimate short-circuit breaking capacity of 150 kA at 415 V, the E6.3X 4000 is designed for demanding low-voltage power distribution applications where a very high short-circuit breaking capacity is required. This product is supplied as the moving part only (WMP); the compatible fixed part is ordered separately.
Air circuit breakers such as the ABB SACE Emax 3 E6.3X 4000 provide high-current switching and protection for low-voltage electrical distribution systems. The circuit breaker is designed to interrupt fault currents when required while its electronic trip unit manages the configured protection functions.
The Ekip Aware LSIG trip unit combines long-time, short-time, instantaneous and earth-fault protection functions, providing comprehensive protection for electrical distribution equipment. The withdrawable construction also supports maintenance procedures by allowing the moving part to be separated from the fixed installation.
Tick the specs you need, then view products that match.
| Trip Unit | LSIG | |
|---|---|---|
| Device Type | ACB | |
| Current | 4000 A | |
| Poles | 3-pole | |
| Phase | Three Phase | |
| Breaking Capacity | 150 kA | |
| Application | Power distribution | |
| Mounting Type | Withdrawable | |
| Manufacturer | ABB | |
| Series | SACE Emax 3 | |
| Model | E6.3X 4000 | |
| Part number | 1SDA128968R1 | |
| Product type | Air circuit breaker moving part | |
| Configuration | Withdrawable moving part (WMP) | |
| Number of poles | 3 | |
| Rated current (In) | 4000 A | |
| Rated ultimate short-circuit breaking capacity (Icu) | 150 kA at 415 V | |
| Trip unit | Ekip Aware LSIG | |
| Trip protection | Long-time, short-time, instantaneous and earth-fault protection | |
| Fixed part | Ordered separately | |
| HS Code | 85362090 |
The ABB 1SDA128968R1 is the moving part of a SACE Emax 3 E6.3X 4000 withdrawable air circuit breaker used for high-current low-voltage power distribution and electrical protection.
The circuit breaker has a rated current of 4000 A.
The E6.3X 4000 has a rated ultimate short-circuit breaking capacity of 150 kA at 415 V.
The moving part is equipped with an Ekip Aware LSIG electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection functions.
No. The 1SDA128968R1 is the withdrawable moving part (WMP) only, and the compatible fixed part is ordered separately.
ABB SACE Emax 3 air circuit breakers provide high-current switching and protection for demanding low-voltage power distribution systems, with electronic trip technology and withdrawable configurations supporting modern switchgear maintenance requirements.