Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB SACE Emax 3 E1.3N 1250 is a 4-pole 1250 A fixed air circuit breaker with front terminals, an Ekip Aware LSIG trip unit and 66 kA Icu at 415 V.
£6,210.69
The ABB SACE Emax 3 E1.3N 1250 1SDA128868R1 is a high-performance air circuit breaker designed for reliable protection and control in demanding low-voltage power distribution systems. This 4-pole circuit breaker has a rated current of 1250 A and a high short-circuit breaking capacity of 66 kA at 415 V, making it suitable for high-capacity electrical installations.
Equipped with an Ekip Aware LSIG trip unit, the breaker provides comprehensive protection functions covering long-time, short-time, instantaneous and ground-fault conditions. The Ekip Aware platform supports advanced protection and monitoring capabilities for modern power distribution applications.
This is the fixed version of the ABB SACE Emax 3 E1.3N 1250 air circuit breaker, specified with front terminals for straightforward integration into low-voltage switchboards and power distribution assemblies.
The ABB SACE Emax 3 E1.3N 1250 combines a 1250 A current rating with a 66 kA short-circuit breaking capacity at 415 V to provide robust protection for low-voltage distribution systems. Its 4-pole construction makes it suitable for applications where all required poles must be switched and protected.
The Ekip Aware LSIG trip unit provides the core protection functions required for managing overloads, short-circuit conditions and ground faults. The fixed configuration and front terminals of the 1SDA128868R1 support integration into compatible switchboards and electrical distribution assemblies.
The ABB 1SDA128868R1 is a SACE Emax 3 E1.3N 1250 air circuit breaker with a 1250 A rated current, 4-pole configuration, 66 kA Icu at 415 V and an Ekip Aware LSIG trip unit.
The ABB SACE Emax 3 E1.3N 1250 has a rated current (In) of 1250 A.
The rated ultimate short-circuit breaking capacity (Icu) is 66 kA at 415 V.
The 1SDA128868R1 is specified with an Ekip Aware LSIG trip unit, providing long-time, short-time, instantaneous and ground-fault protection functions.
The 1SDA128868R1 is the fixed version of the ABB SACE Emax 3 E1.3N 1250 air circuit breaker and is specified with front terminals.
Trusted by Power Distribution Professionals Worldwide
ABB SACE Emax 3 air circuit breakers provide high-capacity switching and protection for demanding low-voltage power distribution applications, with advanced trip-unit technology and configurable installation solutions.
Tick the specs you need, then view products that match.
| Trip Unit | LSIG | |
|---|---|---|
| Device Type | ACB | |
| Current | 1250 A | |
| Poles | 4-pole | |
| Phase | Three Phase | |
| Breaking Capacity | 66 kA | |
| Application | Power distribution | |
| Mounting Type | Fixed | |
| Manufacturer | ABB | |
| Series | SACE Emax 3 | |
| Frame | E1.3N 1250 | |
| Model | E1.3N 1250 | |
| Product type | Air circuit breaker | |
| Part number | 1SDA128868R1 | |
| Rated current (In) | 1250 A | |
| Rated ultimate short-circuit breaking capacity (Icu) | 66 kA at 415 V | |
| Number of poles | 4 | |
| Trip unit | Ekip Aware LSIG | |
| Protection functions | Long-time, short-time, instantaneous and ground-fault (LSIG) | |
| Installation type | Fixed | |
| Terminal configuration | Front terminals | |
| HS Code | 85362090 |