ABB SACE Emax 3 E1.3N 1600 is a three-pole 1600 A fixed air circuit breaker with Ekip Aware LSIG trip unit, front terminals and 66 kA ultimate short-circuit breaking capacity at 415 V.
£5,136.89
The ABB SACE Emax 3 E1.3N 1600 is a high-performance air circuit breaker (ACB) designed for reliable protection and switching of low-voltage electrical distribution systems. As part of the advanced ABB SACE Emax 3 series, this three-pole breaker is engineered for demanding industrial and commercial power distribution applications requiring dependable circuit protection and high interruption capability.
This breaker combines a 1600 A rated current with an Ekip Aware LSIG electronic trip unit, providing comprehensive long-time, short-time, instantaneous and earth-fault protection functions. The fixed construction with front terminals enables straightforward integration into compatible switchboards and electrical distribution assemblies.
With a rated ultimate short-circuit breaking capacity of 66 kA at 415 V, the ABB E1.3N 1600 delivers robust fault interruption performance for industrial low-voltage distribution systems. Its three-pole fixed design provides reliable switching and protection for high-current electrical installations.
Air circuit breakers such as the ABB SACE Emax 3 E1.3N 1600 are designed to protect electrical distribution systems against overloads and short-circuit conditions while providing controlled switching of high-current circuits. Their robust construction and high interruption capability make them suitable for industrial switchboards and demanding electrical installations.
The Ekip Aware LSIG trip unit provides electronic protection functions covering long-time, short-time, instantaneous and earth-fault conditions. This enables effective coordination of circuit protection within modern low-voltage electrical distribution networks.
Tick the specs you need, then view products that match.
| Trip Unit | LSIG | |
|---|---|---|
| Device Type | ACB | |
| Current | 1600 A | |
| Poles | 3-pole | |
| Phase | Three Phase | |
| Breaking Capacity | 66 kA | |
| Application | Power distribution | |
| Mounting Type | Fixed | |
| Manufacturer | ABB | |
| Series | SACE Emax 3 | |
| Model | E1.3N 1600 | |
| Product type | Air circuit breaker | |
| Part number | 1SDA128816R1 | |
| Rated current (In) | 1600 A | |
| Number of poles | 3 | |
| Rated ultimate short-circuit breaking capacity (Icu) | 66 kA at 415 V | |
| Trip unit | Ekip Aware LSIG | |
| Installation type | Fixed | |
| Terminal configuration | Front terminals | |
| HS Code | 85362090 |
This air circuit breaker is used for protection and switching of high-current low-voltage electrical distribution systems in industrial, commercial and infrastructure installations.
The ABB E1.3N 1600 has a rated current of 1600 A.
The breaker has a rated ultimate short-circuit breaking capacity of 66 kA at 415 V.
The ABB E1.3N 1600 is a three-pole air circuit breaker.
This version is fitted with the Ekip Aware LSIG electronic trip unit, providing long-time, short-time, instantaneous and earth-fault protection functions.
The ABB 1SDA128816R1 is a fixed version air circuit breaker with front terminals.
ABB SACE Emax 3 air circuit breakers are engineered for demanding low-voltage distribution systems where dependable circuit protection, high interruption capability and reliable switching performance are required.
We use cookies