1SDA125754R1 ABB E4.3V 2500 Ekip Aware LSI 4p W MP Air Circuit Breaker

1SDA125754R1 ABB E4.3V 2500 Ekip Aware LSI 4p W MP Air Circuit Breaker

ABB E4.3V 2500 Ekip Aware LSI 4p W MP SACE Emax 3 four-pole withdrawable air circuit breaker moving part rated at 2500 A with Ekip Aware LSI electronic protection and V-level high-breaking-capacity performance.

SKU: 1SDA125754R1MPN: 1SDA125754R1
Price
List Price £20,298.72 ex VAT
Your Price (ex VAT) Save 25%
£15,224.04 25% OFF
You save £5,074.68 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15,224.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£15,224.04

Why Choose the ABB E4.3V 2500 Ekip Aware LSI 4p W MP Air Circuit Breaker?

The ABB E4.3V 2500 Ekip Aware LSI 4p W MP (1SDA125754R1) is a high-performance SACE Emax 3 air circuit breaker moving part designed for protection and switching in demanding low-voltage power distribution systems. Rated at 2500 A, this four-pole withdrawable breaker combines ABB's E4.3 frame with the V high-breaking-capacity performance level and an advanced Ekip Aware LSI electronic trip unit.

As part of the ABB SACE Emax 3 generation, the E4.3V 2500 is engineered for installations requiring high fault-interruption capability, intelligent electronic protection and convenient maintenance. The Ekip Aware LSI configuration provides long-time, short-time and instantaneous overcurrent protection, allowing coordinated protection across complex industrial and infrastructure distribution systems.

This model is supplied as a four-pole withdrawable moving part for integration with a compatible Emax 3 fixed part. Its protection system provides an overload adjustment range of 1000–2500 A, a short-time delayed short-circuit adjustment range of 1500–25000 A and an instantaneous short-circuit adjustment range of 3750–37500 A. The E4.3V platform also delivers an ultimate short-circuit breaking capacity of 150 kA at 400/440 V.

Key Advantages

  • Next-generation ABB SACE Emax 3 air circuit breaker for demanding low-voltage distribution systems.
  • 2500 A rated uninterrupted current for high-current industrial and infrastructure applications.
  • Advanced Ekip Aware LSI electronic trip unit with long-time, short-time and instantaneous protection.
  • Four-pole withdrawable moving-part construction for convenient servicing and replacement.
  • 150 kA ultimate short-circuit breaking capacity at 400/440 V.
  • 100 kA short-time withstand current for 1 second for demanding distribution networks.

Key Features

  • ABB SACE Emax 3 E4.3V air circuit breaker.
  • 2500 A rated uninterrupted current.
  • Four-pole withdrawable moving-part configuration.
  • Ekip Aware LSI electronic trip unit.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • 1000–2500 A overload protection setting range.
  • 1500–25000 A short-time short-circuit setting range.
  • 3750–37500 A instantaneous short-circuit setting range.
  • V high-breaking-capacity performance level.
  • 150 kA Icu at 400/440 V.
  • 100 kA Icw for 1 second.
  • Four auxiliary change-over contacts for signalling and control integration.

Intelligent Power Protection for Modern Electrical Systems

ABB SACE Emax 3 is a next-generation low-voltage air circuit breaker platform developed for resilient and intelligent electrical distribution. The range combines high short-circuit performance with advanced electronic protection and an upgradeable architecture, supporting demanding industrial, commercial and infrastructure power systems.

The Ekip Aware LSI electronic trip unit provides adjustable long-time, short-time and instantaneous protection. Combined with the E4.3V platform's high breaking performance, four-pole construction and withdrawable moving-part design, it provides a flexible protection solution for installations where selectivity, fault-current capability, maintainability and dependable power distribution are critical.

Typical Applications

  • High-current industrial low-voltage power distribution systems.
  • Data centres and critical power infrastructure.
  • Manufacturing and process industry switchboards.
  • Large commercial and building electrical distribution systems.
  • Utility and infrastructure power installations.
  • Four-pole withdrawable main and feeder protection switchboards.

Technical Specifications

Series SACE Emax 3
Order code 1SDA125754R1
EAN / GTIN 8056221263061
Product type Air circuit breaker moving part
Frame E4.3
Performance level V
Rated uninterrupted current (Iu) 2500 A
Rated voltage 690 V
Number of poles 4P
Mounting configuration Withdrawable moving part
Trip unit Ekip Aware LSI
Protection functions LSI
Overload release setting 1000–2500 A
Short-time delayed short-circuit release setting 1500–25000 A
Instantaneous short-circuit release setting 3750–37500 A
Ultimate short-circuit breaking capacity (Icu) at 400/440 V 150 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Main circuit connection Via separate chassis / fixed part
Auxiliary change-over contacts 4
Power loss 743 W
Degree of protection IP30
Operating element Push button
Optional motor operator Yes

Frequently Asked Questions

What is the ABB E4.3V 2500 Ekip Aware LSI 4p W MP used for?

This SACE Emax 3 air circuit breaker moving part is designed for switching and protecting high-current low-voltage power distribution systems in industrial, commercial and infrastructure applications.

What is the rated current of ABB 1SDA125754R1?

The ABB E4.3V 2500 Ekip Aware LSI 4p W MP has a rated uninterrupted current of 2500 A.

What protection functions does the Ekip Aware LSI trip unit provide?

The Ekip Aware LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

Is ABB 1SDA125754R1 fixed or withdrawable?

This model is a four-pole withdrawable moving part designed for integration with a compatible ABB SACE Emax 3 fixed part.

What are the protection setting ranges of ABB 1SDA125754R1?

The overload release is adjustable from 1000–2500 A, the short-time delayed short-circuit release from 1500–25000 A, and the instantaneous short-circuit release from 3750–37500 A.

Trusted by Industrial Power Engineers Worldwide

ABB SACE Emax 3 air circuit breakers combine advanced electronic protection, high short-circuit performance and serviceable withdrawable construction for demanding low-voltage electrical distribution systems.