1SDA124913R1 ABB E4.3V 3200 Ekip Aware LSI 3p FHR Air Circuit Breaker

1SDA124913R1 ABB E4.3V 3200 Ekip Aware LSI 3p FHR Air Circuit Breaker

ABB E4.3V 3200 Ekip Aware LSI 3p FHR SACE Emax 3 three-pole fixed air circuit breaker rated at 3200 A with an Ekip Aware LSI electronic trip unit and rear horizontal terminals.

SKU: 1SDA124913R1MPN: 1SDA124913R1
Price
List Price £18,926.68 ex VAT
Your Price (ex VAT) Save 25%
£14,195.01 25% OFF
You save £4,731.67 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £14,195.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£14,195.01

Why Choose the ABB E4.3V 3200 Ekip Aware LSI 3p FHR Air Circuit Breaker?

The ABB E4.3V 3200 Ekip Aware LSI 3p FHR (1SDA124913R1) is a high-performance SACE Emax 3 air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. Rated at 3200 A, this three-pole fixed breaker combines ABB's E4.3 frame with the high-performance V breaking-capacity level and an advanced Ekip Aware LSI electronic trip unit.

As part of the ABB SACE Emax 3 generation, the E4.3V 3200 is designed around intelligent protection, monitoring and future-ready system integration. The Ekip Aware platform supports ABB's upgradeable digital architecture, while the LSI configuration provides long-time, short-time and instantaneous overcurrent protection for critical electrical distribution systems.

This model features a three-pole fixed configuration with rear horizontal terminals and a rated current of 3200 A. Its Ekip Aware LSI release provides an adjustable long-time protection range of 1280–3200 A and instantaneous protection adjustment from 4800–48000 A, allowing the breaker protection settings to be coordinated with the requirements of the installation.

Key Advantages

  • Next-generation ABB SACE Emax 3 air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated current for high-current industrial and infrastructure applications.
  • Advanced Ekip Aware LSI electronic trip unit with long-time, short-time and instantaneous protection.
  • Three-pole fixed construction for permanent installation within low-voltage switchgear.
  • V performance level for applications requiring high short-circuit breaking capability.
  • Upgradeable Ekip Aware architecture supports intelligent power management and evolving system requirements.

Key Features

  • ABB SACE Emax 3 E4.3V air circuit breaker.
  • 3200 A rated current.
  • Three-pole fixed configuration.
  • Ekip Aware LSI electronic trip unit.
  • Long-time, short-time and instantaneous protection functions.
  • 1280–3200 A long-time protection setting range.
  • 4800–48000 A instantaneous protection setting range.
  • Rear horizontal main terminal arrangement.
  • Four auxiliary contacts for signalling and control integration.
  • Open/closed circuit breaker status indication.
  • Part of ABB's intelligent and upgradeable Emax 3 circuit breaker platform.

Intelligent Power Protection for Modern Electrical Systems

ABB SACE Emax 3 is a next-generation low-voltage air circuit breaker platform developed for secure, resilient and increasingly digital power infrastructure. The range combines advanced electrical protection with intelligent power management, measurement, diagnostics and scalable connectivity, helping operators improve system visibility and continuity across critical installations.

The Ekip Aware LSI electronic trip unit gives the E4.3V 3200 configurable long-time, short-time and instantaneous protection while forming part of ABB's upgradeable Ekip architecture. This makes the breaker particularly suitable for installations that require dependable high-current protection today while retaining flexibility for future monitoring, communication and power-management requirements.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Data centres and critical power infrastructure.
  • Manufacturing and process industry switchboards.
  • Commercial and large-building electrical distribution.
  • Utility and infrastructure power systems.
  • High-current main distribution and protection switchboards.

Technical Specifications

Series SACE Emax 3
Order code 1SDA124913R1
EAN 8056221254656
Product type Air circuit breaker
Frame E4.3
Performance level V
Rated current 3200 A
Number of poles 3P
Mounting configuration Fixed
Trip unit Ekip Aware
Protection functions LSI
Long-time protection setting (I1) 1280–3200 A
Instantaneous protection setting (I3) 4800–48000 A
Main terminal arrangement Rear horizontal
Auxiliary contacts 4
Position indication Circuit breaker open / closed

Frequently Asked Questions

What is the ABB E4.3V 3200 Ekip Aware LSI 3p FHR used for?

This SACE Emax 3 air circuit breaker is designed for switching and protecting high-current low-voltage power distribution systems in industrial, commercial and infrastructure applications.

What is the rated current of ABB 1SDA124913R1?

The ABB E4.3V 3200 Ekip Aware LSI 3p FHR has a rated current of 3200 A.

What protection functions does the Ekip Aware LSI trip unit provide?

The Ekip Aware LSI trip unit provides long-time, short-time and instantaneous overcurrent protection functions for coordinated electrical system protection.

Is ABB 1SDA124913R1 fixed or withdrawable?

This model is a three-pole fixed air circuit breaker with rear horizontal main terminals.

What are the protection setting ranges?

The long-time protection setting range is 1280–3200 A, while the instantaneous protection setting range is 4800–48000 A.

Trusted by Industrial Power Engineers Worldwide

ABB SACE Emax 3 air circuit breakers combine advanced circuit protection, intelligent power management and upgradeable digital capabilities for demanding low-voltage electrical distribution systems.