The ABB 1SDA124818R1 is an E2.3N 1250 three-pole fixed Emax 3 air circuit breaker with Ekip Aware LSI electronic protection and rear horizontal connections.

SKU: 1SDA124818R1
Price
List Price £6,108.40 ex VAT
Your Price (ex VAT) Save 25%
£4,581.30 25% OFF
You save £1,527.10 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,581.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,581.30

ABB 1SDA124818R1 E2.3N 1250 Ekip Aware LSI 3P FHR Air Circuit Breaker

The ABB 1SDA124818R1 is an Emax 3 E2.3N 1250 air circuit breaker featuring an Ekip Aware LSI electronic trip unit, three-pole fixed construction and rear horizontal connections for dependable low-voltage power distribution.

With a rated current of 1250 A and a rated voltage of up to 690 V AC, this SACE Emax 3 circuit breaker provides long-time, short-time and instantaneous protection for demanding industrial and commercial electrical distribution systems.

The fixed FHR configuration provides rear horizontal terminals and four auxiliary contacts, making the ABB 1SDA124818R1 suitable for integration into compatible switchboards, main distribution boards and high-capacity feeder applications.

Key Advantages

  • 1250 A rated current for high-capacity power distribution.
  • Ekip Aware electronic trip unit with LSI protection functions.
  • Three-pole fixed configuration for straightforward switchboard installation.
  • 66 kA interrupting capability at 440 V AC.
  • 66 kA short-time withstand capability for 1 s.
  • Rear horizontal terminal arrangement for practical panel integration.
  • Four auxiliary contacts for additional control and signalling functions.

Key Features

  • ABB SACE Emax 3 E2.3N air circuit breaker.
  • Order code: 1SDA124818R1.
  • Ekip Aware LSI electronic release.
  • Long-time, short-time and instantaneous protection functions.
  • 1250 A rated current.
  • 690 V AC rated voltage.
  • 3-pole fixed construction.
  • Rear horizontal terminal configuration.
  • Four auxiliary contacts.
  • Open/closed position indication.
  • Suitable for high-capacity low-voltage distribution applications.

High-Capacity Electronic Circuit Protection

The ABB 1SDA124818R1 combines the Emax 3 E2.3N platform with Ekip Aware LSI electronic protection to provide controlled interruption and protection for high-current distribution circuits. Its LSI protection arrangement addresses overload and short-circuit conditions through configurable long-time, short-time and instantaneous functions.

The 1250 A frame is designed for high-capacity low-voltage distribution, while the fixed three-pole construction and rear horizontal terminals support integration into compatible switchboards. The 66 kA interrupting and short-time withstand ratings provide a robust protection capability for demanding electrical distribution environments.

Typical Applications

  • Main low-voltage distribution boards.
  • Industrial power distribution systems.
  • Commercial electrical switchboards.
  • High-current feeder protection.
  • Manufacturing and process installations.
  • Infrastructure and building power systems.
  • Power distribution and electrical protection assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Trip Unit LSI
Device Type ACB
Current 1250 A
Poles 3-pole
Phase Three Phase
Breaking Capacity 66 kA
Application Power distribution
Mounting Type Fixed
Manufacturer ABB
Product family SACE Emax 3
Series E2.3N
Order code 1SDA124818R1
Rated current 1250 A
Rated voltage 690 V AC
Mounting configuration Fixed
Trip unit Ekip Aware
Protection LSI
Long-time protection setting I1 500–1250 A
Instantaneous protection setting I3 1875–18750 A
Rated ultimate short-circuit breaking capacity Icu 66 kA at 440 V AC
Short-time withstand current Icw 66 kA for 1 s
Terminal arrangement Rear horizontal
Configuration FHR
Auxiliary contacts 4
EAN 8056221253703
HS Code 85362090

Frequently Asked Questions

What is the ABB 1SDA124818R1?

The ABB 1SDA124818R1 is an Emax 3 E2.3N 1250 three-pole fixed air circuit breaker with an Ekip Aware LSI electronic trip unit.

What is the rated current of the 1SDA124818R1?

The ABB 1SDA124818R1 has a rated current of 1250 A.

What protection functions does the Ekip Aware LSI release provide?

The Ekip Aware LSI release provides long-time, short-time and instantaneous protection functions for managing overload and short-circuit conditions.

What is the short-circuit rating of the ABB 1SDA124818R1?

The ABB 1SDA124818R1 has an Icu of 66 kA at 440 V AC and an Icw of 66 kA for 1 s.

Where can the ABB 1SDA124818R1 be used?

The 1SDA124818R1 is suitable for high-capacity low-voltage distribution applications including industrial switchboards, commercial distribution systems and high-current feeder circuits.

Trusted for Industrial Power Distribution

The ABB 1SDA124818R1 E2.3N 1250 Ekip Aware LSI 3P FHR combines high-current switching capability, electronic LSI protection and a fixed rear-horizontal configuration for dependable integration into demanding low-voltage power distribution systems.