Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-A1C-125L3 is a 125 A single-pole Formula A1N125 moulded case circuit breaker with TMA thermal-magnetic protection and LSC L3 configuration, designed for compatible Protecta Power low-voltage distribution assemblies.
£210.79
The ABB EPX-A1C-125L3 is a reliable 125 A single-pole moulded case circuit breaker (MCCB) designed for overload and short-circuit protection in low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, this circuit breaker incorporates the ABB Formula A1N125 platform, providing dependable thermal-magnetic protection for commercial and industrial electrical installations.
The EPX-A1C-125L3 features a TMA thermal-magnetic trip unit, combining thermal overload protection with magnetic short-circuit protection. This arrangement helps protect electrical circuits against excessive current while providing a straightforward protective solution for outgoing distribution circuits. The device is specified with a single-pole configuration and LSC L3 arrangement for integration into compatible ABB Protecta Power assemblies.
With a rated current of 125 A and an A1N125 circuit breaker designation, the EPX-A1C-125L3 is suitable for single-phase outgoing circuit applications requiring appropriately rated protection. The ABB Formula A1N125 single-pole range is associated with a 25 kA ultimate short-circuit breaking capacity at 415 V AC, subject to the manufacturer's applicable operating conditions. Identified by ABB order code 1SDA123222R1, this device provides a coordinated solution for professional low-voltage distribution panel construction.
Moulded case circuit breakers protect electrical circuits by automatically interrupting current when overload or short-circuit conditions occur. Thermal-magnetic MCCBs combine two complementary protection mechanisms: a thermal element that responds to sustained overcurrent and a magnetic element that responds rapidly to high short-circuit currents.
The ABB EPX-A1C-125L3 uses a TMA thermal-magnetic trip arrangement to provide these protective functions within a compact single-pole circuit breaker. Thermal protection helps prevent prolonged overload conditions from damaging cables and connected equipment, while magnetic protection provides rapid fault interruption when sufficiently high short-circuit currents occur.
The ABB Formula A1N125 platform is developed for low-voltage circuit protection applications requiring reliable switching and protective performance. Its moulded case construction provides a practical solution for outgoing feeder protection in commercial and industrial electrical distribution systems.
Within the ABB Protecta Power system, the EPX-A1C-125L3 is specified for an LSC L3 outgoing arrangement. This configuration supports integration into the corresponding distribution assembly layout. Correct installation requires selection of compatible mounting accessories, verification of available fault current and coordination with upstream and downstream protective devices. Circuit breaker ratings and protective settings must be assessed against the applicable ABB documentation and installation requirements.
The ABB EPX-A1C-125L3 is a 125 A single-pole moulded case circuit breaker designed to protect outgoing electrical distribution circuits against overload and short-circuit conditions within compatible ABB Protecta Power assemblies.
The EPX-A1C-125L3 has a rated current of 125 A and uses the ABB Formula A1N125 circuit breaker platform.
The circuit breaker uses a TMA thermal-magnetic trip unit, combining thermal overload protection with magnetic short-circuit protection for low-voltage electrical distribution applications.
The corresponding ABB Formula A1N125 single-pole performance configuration has an ultimate short-circuit breaking capacity of 25 kA at 415 V AC. The applicable rating must be verified against the installation voltage and manufacturer-specified operating conditions.
LSC L3 is the manufacturer-specified configuration designation for this Protecta Power outgoing circuit breaker arrangement. The L3 designation identifies the associated outgoing position or phase arrangement within the compatible distribution system.
The EPX-A1C-125L3 is a single-pole (1P) MCCB, designed for applications requiring protection and switching of one circuit pole.
The ABB order code is 1SDA123222R1, identifying the EPX-A1C-125L3 A1N125 125 A single-pole MCCB with LSC L3 configuration and TMA thermal-magnetic protection.
ABB Formula moulded case circuit breakers and Protecta Power distribution components provide electrical contractors, panel builders and system integrators with coordinated solutions for low-voltage electrical protection. The EPX-A1C-125L3 combines a 125 A single-pole A1N125 circuit breaker with TMA thermal-magnetic protection and an LSC L3 configuration to support dependable outgoing circuit protection in compatible distribution assemblies.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.