1SDA123219R1 ABB EPX-A1C-080L3 A1N125 80A 1P LSC L3 TMA Circuit Breaker

1SDA123219R1 ABB EPX-A1C-080L3 A1N125 80A 1P LSC L3 TMA Circuit Breaker

ABB EPX-A1C-080L3 is an 80 A single-pole A1N125 moulded case circuit breaker assembly with TMA thermal-magnetic protection, 25 kA breaking capacity and an LSC L3 connection arrangement for compatible Protecta Power distribution systems.

SKU: 1SDA123219R1Alt SKU: EPX-A1C-080L3MPN: 1SDA123219R1
Price
List Price £204.11 ex VAT
Your Price (ex VAT)
£204.11
Manufacturer Lead Time Estimated Delivery 4 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £204.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£204.11

Why Choose the ABB EPX-A1C-080L3 Protecta Power Circuit Breaker?

The ABB EPX-A1C-080L3 is a reliable 80 A single-pole moulded case circuit breaker (MCCB) assembly designed for electrical circuit protection in commercial and industrial low-voltage distribution systems. As part of the ABB Protecta Power Devices range, this product combines an ABB Formula A1N125 circuit breaker with an LSC L3 connection arrangement and thermal-magnetic protection for integration into compatible electrical distribution boards.

The EPX-A1C-080L3 provides dependable protection against overloads and short circuits, helping safeguard electrical conductors, connected equipment and distribution infrastructure. Its TMA thermal-magnetic protection configuration combines thermal overload protection with magnetic short-circuit protection, while the L3 connection arrangement supports phase-specific installation within ABB Protecta Power assemblies.

With a rated current of 80 A, a 125 A circuit breaker frame and a 25 kA short-circuit breaking capacity for the specified Protecta Power application, the EPX-A1C-080L3 is suitable for outgoing circuit protection in commercial switchboards, industrial distribution panels and building electrical infrastructure.

Key Advantages

  • 80 A single-pole MCCB designed for reliable outgoing circuit protection.
  • ABB Formula A1N125 circuit breaker platform for low-voltage electrical distribution.
  • 25 kA short-circuit breaking capacity for the specified Protecta Power application.
  • TMA thermal-magnetic protection provides overload and short-circuit protection.
  • LSC L3 connection configuration supports integration into compatible ABB distribution assemblies.
  • 125 A frame rating provides a standardised circuit breaker platform.
  • Compact single-pole design supports efficient use of distribution board space.
  • Suitable for commercial, industrial and building services electrical installations.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-A1C-080L3 model designation.
  • ABB Formula A1N125 moulded case circuit breaker platform.
  • 80 A rated current.
  • 125 A frame size.
  • Single-pole (1P) circuit protection configuration.
  • 25 kA breaking capacity in the specified Protecta Power application.
  • TMA thermal-magnetic trip arrangement.
  • LSC L3 connection configuration.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit faults.
  • Designed for compatible ABB Protecta Power outgoing MCCB installations.
  • Suitable for low-voltage electrical distribution and circuit isolation.

Reliable Thermal-Magnetic Protection for Electrical Distribution

The ABB EPX-A1C-080L3 provides electrical circuit protection using thermal-magnetic technology. The thermal protection element responds to sustained overcurrent conditions, helping prevent overheating of electrical conductors and connected equipment. The magnetic protection element responds rapidly to short-circuit faults, reducing the potential for damage within electrical distribution systems.

The ABB Formula A1N125 platform is designed for compact and dependable low-voltage circuit protection. Its single-pole configuration enables protection of individual outgoing phase circuits, while the LSC L3 connection arrangement supports integration into compatible ABB Protecta Power distribution board assemblies.

The ABB Protecta Power system provides a structured approach to electrical distribution using compatible circuit breakers, mounting components and connection arrangements. Correct selection of the circuit breaker, associated accessories and upstream protection is essential to ensure safe operation and suitable protection coordination.

Typical Applications

  • ABB Protecta Power electrical distribution boards.
  • Commercial building power distribution systems.
  • Industrial low-voltage electrical switchboards.
  • 80 A outgoing feeder and circuit protection.
  • Single-pole electrical distribution circuits.
  • Building services and electrical infrastructure panels.
  • Office, retail and commercial electrical installations.
  • Electrical panel manufacturing and switchboard assembly.

Technical Specifications

Product range Protecta Power Devices
Series ABB Formula A1
ABB order code 1SDA123219R1
Product type Moulded case circuit breaker (MCCB) assembly
Circuit breaker designation A1N125
Rated current 80 A
Frame rating 125 A
Number of poles 1P (single pole)
Short-circuit breaking capacity 25 kA (specified Protecta Power application)
Trip unit designation TMA thermal-magnetic
Protection functions Thermal overload and magnetic short-circuit protection
Connection arrangement LSC L3
Phase configuration L3
Mounting arrangement Compatible Protecta Power MCCB mounting assembly
Installation Low-voltage electrical distribution boards
Compatible system ABB Protecta Power
Product category Protecta Power Devices

Frequently Asked Questions

What is the ABB EPX-A1C-080L3 used for?

The ABB EPX-A1C-080L3 is an 80 A single-pole moulded case circuit breaker assembly designed to protect outgoing electrical circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.

What is the rated current of the EPX-A1C-080L3?

The EPX-A1C-080L3 has a rated current of 80 A and uses the ABB Formula A1N125 circuit breaker platform with a 125 A frame rating.

What breaking capacity does the ABB EPX-A1C-080L3 provide?

The EPX-A1C-080L3 is specified with a 25 kA breaking capacity for the ABB Protecta Power application. The applicable voltage and installation conditions must be considered when verifying short-circuit protection requirements.

What does TMA mean on the ABB EPX-A1C-080L3?

TMA identifies the thermal-magnetic protection arrangement, providing thermal protection against sustained overloads and magnetic protection against short-circuit faults.

What does the L3 designation indicate?

The L3 designation identifies the third-phase connection arrangement used for installation within compatible ABB Protecta Power distribution assemblies.

Is the EPX-A1C-080L3 compatible with ABB Protecta Power distribution boards?

Yes. The EPX-A1C-080L3 belongs to the ABB Protecta Power Devices range and is designed for compatible distribution board installations. The appropriate MCCB mounting base plate, cover and associated accessories must be selected for the installation.

Trusted ABB Circuit Protection for Power Distribution

ABB Protecta Power circuit protection devices support reliable electrical distribution in commercial and industrial installations. The EPX-A1C-080L3 combines an 80 A A1N125 single-pole circuit breaker, thermal-magnetic protection and an LSC L3 connection arrangement to provide dependable outgoing circuit protection within compatible Protecta Power assemblies.