ABB EPX-A1C-063L3 is a 63 A single-pole A1N125 moulded case circuit breaker assembly with thermal-magnetic protection, 25 kA breaking capacity and an LSC L3 connection arrangement for compatible Protecta Power distribution systems.
£202.76
The ABB EPX-A1C-063L3 is a dependable 63 A single-pole moulded case circuit breaker (MCCB) assembly designed for overload and short-circuit protection in commercial and industrial electrical distribution systems. Part of the ABB Protecta Power Devices range, this product combines an ABB Formula A1N125 circuit breaker with an LSC L3 connection arrangement for integration into compatible low-voltage distribution boards.
The EPX-A1C-063L3 uses thermal-magnetic protection to safeguard outgoing electrical circuits against excessive current and short-circuit faults. Its compact single-pole configuration helps optimise distribution board space, while the L3 connection arrangement supports phase-specific installation within ABB Protecta Power assemblies.
With a 63 A rated current, 125 A frame size and 25 kA short-circuit breaking capacity in the specified Protecta Power application, the EPX-A1C-063L3 provides reliable circuit protection for electrical distribution panels, commercial switchboards and industrial installations.
The ABB EPX-A1C-063L3 is designed to protect electrical distribution circuits using thermal-magnetic circuit breaker technology. The thermal protection element responds to sustained overload conditions, while the magnetic element provides rapid disconnection when high short-circuit currents occur. Together, these functions help protect connected electrical equipment, conductors and distribution infrastructure.
The ABB Formula A1N125 circuit breaker platform provides a compact solution for low-voltage power distribution. Its single-pole construction is suitable for individual outgoing phase circuits, while the LSC L3 connection arrangement enables integration into compatible ABB Protecta Power distribution assemblies.
For reliable installation, the circuit breaker must be selected according to the electrical system voltage, prospective fault current, conductor capacity and protection coordination requirements. Compatible ABB Protecta Power mounting components and covers should be used to complete the distribution board assembly.
| Product range | Protecta Power Devices |
|---|---|
| Series | ABB Formula A1 |
| ABB order code | 1SDA123217R1 |
| Product type | Moulded case circuit breaker assembly |
| Circuit breaker designation | A1N125 |
| Rated current | 63 A |
| Frame rating | 125 A |
| Number of poles | 1P (single pole) |
| Short-circuit breaking capacity | 25 kA (specified Protecta Power application) |
| Trip unit designation | TMA thermal-magnetic |
| Protection functions | Overload and short-circuit protection |
| Connection configuration | LSC L3 |
| Phase arrangement | L3 |
| Installation type | Distribution board mounting with compatible accessories |
| Compatible system | ABB Protecta Power |
| Application | Low-voltage outgoing circuit protection |
| Product category | Protecta Power Devices |
The ABB EPX-A1C-063L3 is a 63 A single-pole moulded case circuit breaker assembly designed to protect outgoing electrical circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.
The EPX-A1C-063L3 has a 63 A rated current and uses the ABB Formula A1N125 circuit breaker platform with a 125 A frame rating.
The EPX-A1C-063L3 is listed with a 25 kA breaking capacity for the specified ABB Protecta Power application. The applicable voltage and installation conditions must be checked when assessing short-circuit protection requirements.
TMA identifies the thermal-magnetic protection arrangement, combining overload protection with magnetic short-circuit protection. The precise trip characteristics depend on the installed circuit breaker configuration.
The L3 designation identifies the third-phase connection arrangement used for installation within compatible ABB Protecta Power distribution assemblies.
Yes. The EPX-A1C-063L3 belongs to the ABB Protecta Power Devices range and is intended for compatible distribution board installations. The appropriate MCCB base plate, cover and installation accessories must be selected separately where required.
ABB Protecta Power circuit protection devices support dependable electrical distribution in commercial and industrial installations. The EPX-A1C-063L3 combines a 63 A A1N125 single-pole circuit breaker, thermal-magnetic protection and an LSC L3 connection arrangement to provide reliable outgoing circuit protection within compatible Protecta Power assemblies.