1SDA123215R1 ABB EPX-A1C-050L3 Protecta Power 50A 1-Pole A1N125 Thermal Magnetic MCCB with LSC L3

1SDA123215R1 ABB EPX-A1C-050L3 Protecta Power 50A 1-Pole A1N125 Thermal Magnetic MCCB with LSC L3

ABB EPX-A1C-050L3 (1SDA123215R1) 50 A single-pole Formula A1N125 thermal-magnetic outgoing MCCB with LSC L3 connection arrangement for compatible ABB Protecta Power electrical distribution panelboards.

SKU: 1SDA123215R1Alt SKU: EPX-A1C-050L3MPN: 1SDA123215R1
Price
List Price £194.77 ex VAT
Your Price (ex VAT)
£194.77
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.77

Why Choose the ABB EPX-A1C-050L3 50A Single-Pole Thermal-Magnetic MCCB?

The ABB EPX-A1C-050L3 is a 50 A single-pole moulded case circuit breaker (MCCB) with an LSC L3 connection arrangement, designed for compatible ABB Protecta Power electrical distribution panelboards. Identified by manufacturer order code 1SDA123215R1, this device belongs to the Protecta Power Devices product group and provides a dedicated outgoing circuit protection solution for professional low-voltage distribution installations.

Built around the ABB Formula A1N125 circuit breaker platform, the EPX-A1C-050L3 uses thermal-magnetic protection to respond to overload and short-circuit conditions. Its 50 A current rating and single-pole (1P) configuration make it suitable for appropriately designed outgoing circuits requiring MCCB protection within a compatible ABB Protecta Power assembly.

The product's LSC L3 designation identifies its connection variant within ABB's single-pole outgoing MCCB range. ABB's Protecta Power selection literature lists the corresponding 50 A A1N125 outgoing device within its 25 kA product classification, although the applicable breaking capacity must be verified against the device's rated operational voltage and detailed technical documentation. The EPX-A1C-050L3 offers electrical contractors, consulting engineers and panel builders a clearly identified ABB outgoing protection option for suitable distribution panelboards.

Key Advantages

  • Purpose-designed 50 A outgoing MCCB for compatible ABB Protecta Power distribution panelboards.
  • Single-pole (1P) configuration for appropriately designed individual outgoing circuits.
  • Based on the ABB Formula A1N125 moulded case circuit breaker platform.
  • Provides thermal-magnetic overload and short-circuit protection.
  • Listed in ABB Protecta Power selection literature within the 25 kA A1 outgoing device range, subject to verification of the applicable voltage and breaking-capacity rating.
  • Specified with an LSC L3 connection arrangement for the corresponding outgoing device configuration.
  • Combines manual circuit switching with automatic overcurrent tripping.
  • Supports coordinated outgoing circuit protection within compatible ABB distribution assemblies.
  • Clearly differentiated from the corresponding L1 and L2 connection variants.
  • Suitable for commercial, industrial and institutional low-voltage distribution applications.
  • Supports professional panelboard construction, compatible replacement and refurbishment projects.
  • Genuine ABB product identified by manufacturer order code 1SDA123215R1.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-A1C-050L3 product reference.
  • 50 A rated current.
  • Single-pole (1P) circuit breaker configuration.
  • ABB Formula A1N125 circuit breaker family.
  • 125 A frame family with a 50 A device rating.
  • Thermal-magnetic (TMA) protection designation.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit conditions.
  • ABB Protecta Power 25 kA outgoing device classification, with the applicable rated breaking capacity to be verified.
  • LSC L3 connection arrangement.
  • Designed for compatible ABB Protecta Power outgoing circuit positions.
  • Corresponding L1 and L2 variants available for alternative connection arrangements.
  • Manual circuit switching and automatic protective tripping.
  • Requires compatible outgoing MCCB mounting and cover components within the completed panelboard assembly.
  • ABB manufacturer order code 1SDA123215R1.

Reliable 50A Outgoing Circuit Protection with ABB Formula A1N125 Technology

Outgoing circuit protection is an essential part of a professionally designed low-voltage electrical distribution panelboard. Each outgoing protective device must be selected according to the connected load, conductor characteristics, installation conditions and prospective fault current. The ABB EPX-A1C-050L3 provides a 50 A single-pole MCCB solution for compatible Protecta Power assemblies, helping protect the connected circuit against overload and short-circuit conditions.

The product uses the ABB Formula A1N125 circuit breaker platform. The A1N125 designation identifies the breaker family and its 125 A frame classification, while the 50 A rating identifies the current rating of this particular outgoing device. The frame rating should not be confused with the specified protective device rating, which must be considered when assessing the connected circuit and its conductor requirements.

The thermal-magnetic protection arrangement combines two complementary overcurrent protection functions. The thermal element responds to sustained overload conditions that may cause excessive heating in electrical conductors and equipment. The magnetic element responds to sufficiently high short-circuit currents, providing rapid protective tripping when the applicable operating threshold is reached.

ABB's Protecta Power selection literature lists the 50 A single-pole A1N125 outgoing MCCB in its 25 kA outgoing device range. This classification is useful when identifying the correct product family, but it should not replace verification of the actual breaking-capacity rating. ABB's device-level documentation may distinguish ratings by operational voltage, test conditions and applicable standards. The electrical designer must confirm that the selected device has adequate short-circuit breaking capacity for the intended installation.

The LSC L3 designation is a significant part of the EPX-A1C-050L3 product reference. ABB identifies corresponding 50 A single-pole outgoing variants as EPX-A1C-050L1, EPX-A1C-050L2 and EPX-A1C-050L3. These variants allow the appropriate connection arrangement to be specified for the intended panelboard position. They should not be substituted without confirming the approved distribution assembly configuration.

The ABB Protecta Power outgoing MCCB system uses dedicated mounting and cover components to integrate protective devices into the finished panelboard. ABB's selection literature specifies that an MCCB base plate and cover are required with each outgoing device. The EPX-A1C-050L3 should therefore be treated as a protective device for installation within a compatible distribution assembly rather than a complete enclosed electrical distribution product.

ABB's published Protecta Power information identifies a maximum cable capacity of 50 mm² for A1 single-pole devices. This is a connection capacity for the relevant device arrangement, not a recommended cable size for a 50 A circuit. The correct conductor cross-section must be selected according to the connected load, installation method, current-carrying capacity, voltage drop, fault protection requirements and terminal compatibility.

When specifying the EPX-A1C-050L3, the electrical designer must verify the rated operational voltage, short-circuit breaking capacity, thermal-magnetic trip characteristics, conductor compatibility and panelboard installation requirements. Appropriate coordination with upstream protective devices must also be considered. Installation and commissioning should follow current ABB technical documentation and applicable electrical installation standards.

Typical Applications

  • ABB Protecta Power outgoing electrical distribution circuits.
  • 50 A single-pole MCCB protection within compatible panelboards.
  • Protecta Power assemblies requiring the LSC L3 connection arrangement.
  • Commercial building low-voltage distribution systems.
  • Industrial electrical distribution panelboards.
  • Individual outgoing circuits requiring appropriately specified overcurrent protection.
  • Office and retail electrical installations.
  • Warehouses and logistics facilities.
  • Manufacturing and light industrial premises.
  • Educational and institutional building distribution systems.
  • Electrical switchrooms and sub-distribution assemblies.
  • Professional electrical panel building and switchgear manufacturing.
  • Compatible outgoing MCCB replacement applications.
  • Protecta Power panelboard refurbishment and expansion projects.

Technical Specifications

Product group Protecta Power Devices
Compatible distribution range ABB Protecta Power
ABB order code 1SDA123215R1
Manufacturer product description A1N125 50A 1p + LSC L3 TMA
Product type Moulded case circuit breaker (MCCB) with LSC connection arrangement
Device application Outgoing circuit protection
Rated current 50 A
Number of poles 1P (single-pole)
Circuit breaker family ABB Formula A1N125
Frame family 125 A
Protection technology Thermal-magnetic
Trip designation TMA
Overload protection Thermal trip function
Short-circuit protection Magnetic trip function
ABB Protecta Power catalogue classification 25 kA outgoing MCCB range; confirm the applicable rated breaking capacity at the installation voltage
Connection arrangement LSC L3
Connection variant L3
Alternative connection variants EPX-A1C-050L1 and EPX-A1C-050L2
Published A1 single-pole maximum cable capacity 50 mm², subject to terminal and installation requirements
Associated mounting components Compatible outgoing MCCB base plate and cover
Operating functionality Manual switching and automatic overcurrent tripping
System type Low-voltage electrical distribution
Application Compatible ABB Protecta Power outgoing circuits

Frequently Asked Questions

What is the ABB EPX-A1C-050L3 used for?

The ABB EPX-A1C-050L3 is a 50 A single-pole thermal-magnetic MCCB with an LSC L3 connection arrangement. It is designed for compatible ABB Protecta Power outgoing distribution circuits and provides overload and short-circuit protection.

What does L3 mean in the ABB EPX-A1C-050L3 product code?

L3 identifies the specified connection variant within ABB's Protecta Power single-pole outgoing MCCB range. ABB also lists EPX-A1C-050L1 and EPX-A1C-050L2 versions. The correct variant should be selected according to the approved panelboard connection arrangement.

What is the current rating and pole configuration of the EPX-A1C-050L3?

The EPX-A1C-050L3 has a 50 A current rating and a single-pole (1P) configuration. It belongs to the ABB Formula A1N125 circuit breaker family. The 125 A frame designation does not change the device's specified 50 A rating.

What is the breaking capacity of the ABB EPX-A1C-050L3?

ABB's Protecta Power selection literature lists the 50 A single-pole A1N125 outgoing MCCB within its 25 kA product range. The applicable rated breaking capacity must be confirmed against the exact device documentation at the intended operational voltage before installation. The catalogue range classification should not be treated as a universal breaking-capacity rating.

Does the ABB EPX-A1C-050L3 require a separate base plate and cover?

Yes. ABB's Protecta Power selection literature specifies that an MCCB base plate and cover are required with each outgoing device. The correct accessories must be selected for the panelboard and circuit breaker arrangement. The EPX-A1C-050L3 is not a complete enclosed distribution assembly on its own.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB Protecta Power provides coordinated low-voltage electrical distribution components for commercial and industrial installations. The EPX-A1C-050L3 combines a 50 A single-pole Formula A1N125 circuit breaker with thermal-magnetic protection and an LSC L3 connection arrangement, giving electrical contractors and panel builders a clearly identified outgoing protection option for compatible Protecta Power assemblies.