1SDA123214R1 ABB EPX-A1C-040L3 Protecta Power 40A 1-Pole A1N125 Thermal Magnetic MCCB with LSC L3

1SDA123214R1 ABB EPX-A1C-040L3 Protecta Power 40A 1-Pole A1N125 Thermal Magnetic MCCB with LSC L3

ABB EPX-A1C-040L3 (1SDA123214R1) 40 A single-pole Formula A1N125 thermal-magnetic outgoing MCCB with LSC L3 connection arrangement and 25 kA published breaking-capacity classification for compatible ABB Protecta Power distribution panelboards.

SKU: 1SDA123214R1Alt SKU: EPX-A1C-040L3MPN: 1SDA123214R1
Price
List Price £194.77 ex VAT
Your Price (ex VAT)
£194.77
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.77

Why Choose the ABB EPX-A1C-040L3 40A Single-Pole Thermal-Magnetic MCCB?

The ABB EPX-A1C-040L3 is a 40 A single-pole moulded case circuit breaker (MCCB) with an LSC L3 connection arrangement, designed for compatible ABB Protecta Power electrical distribution panelboards. Identified by ABB manufacturer order code 1SDA123214R1, this device belongs to the Protecta Power Devices product group and provides dedicated outgoing circuit protection for professional low-voltage electrical installations.

Based on the ABB Formula A1N125 circuit breaker platform, the EPX-A1C-040L3 uses thermal-magnetic (TMA) protection to respond to overload and short-circuit conditions. Its 40 A rated current and single-pole (1P) configuration make it suitable for appropriately designed outgoing circuits where a moulded case circuit breaker is required within a compatible Protecta Power assembly.

ABB's Protecta Power selection literature identifies the 40 A single-pole A1N125 outgoing MCCB with a 25 kA breaking-capacity classification. The product's L3 designation identifies the specified connection variant, distinguishing it from the corresponding L1 and L2 versions. Together, these characteristics provide a clearly identified outgoing protection solution for electrical contractors, consulting engineers and panel builders specifying ABB distribution equipment.

Key Advantages

  • Purpose-designed 40 A outgoing MCCB for compatible ABB Protecta Power electrical distribution panelboards.
  • Single-pole (1P) configuration for suitable individual outgoing circuit protection applications.
  • Based on the established ABB Formula A1N125 moulded case circuit breaker platform.
  • Provides thermal-magnetic overload and short-circuit protection.
  • Features a 25 kA breaking-capacity classification in ABB's Protecta Power selection literature, subject to the applicable operational voltage.
  • Specified with an LSC L3 connection arrangement for the corresponding outgoing device configuration.
  • Combines manual circuit switching with automatic overcurrent tripping.
  • Supports coordinated outgoing circuit breaker selection across compatible Protecta Power assemblies.
  • Clearly differentiated from the corresponding L1 and L2 connection variants.
  • Suitable for commercial, industrial and institutional low-voltage electrical distribution installations.
  • Supports professional panelboard construction, device replacement and compatible refurbishment projects.
  • Genuine ABB product identified by manufacturer order code 1SDA123214R1.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-A1C-040L3 manufacturer product reference.
  • 40 A rated current.
  • Single-pole (1P) circuit breaker configuration.
  • ABB Formula A1N125 circuit breaker family.
  • 125 A frame family with a 40 A device rating.
  • Thermal-magnetic (TMA) overcurrent protection.
  • Thermal response to sustained overload conditions.
  • Magnetic response to short-circuit conditions.
  • 25 kA published breaking-capacity classification for the corresponding outgoing device.
  • LSC L3 connection arrangement.
  • Designed for compatible ABB Protecta Power outgoing circuit positions.
  • Corresponding L1 and L2 variants available for alternative connection arrangements.
  • Manual circuit switching and automatic protective tripping.
  • Requires appropriate outgoing MCCB mounting and cover components within the completed panelboard assembly.
  • ABB manufacturer order code 1SDA123214R1.

Reliable 40A Outgoing Circuit Protection with ABB Formula A1N125 Technology

Outgoing circuit protection is an essential element of a professionally designed electrical distribution panelboard. Each protective device must be selected to suit the connected electrical load, conductor characteristics, installation conditions and prospective fault current. The ABB EPX-A1C-040L3 provides a 40 A single-pole MCCB solution for compatible Protecta Power assemblies, helping protect the outgoing circuit against overload and short-circuit conditions.

The device uses the ABB Formula A1N125 circuit breaker platform. The A1N125 designation identifies the circuit breaker family and its 125 A frame classification, while the 40 A rating identifies the current rating of this particular protective device. These values serve different purposes: the frame designation describes the breaker family, whereas the 40 A rating is relevant to the selection of the outgoing circuit protection.

The thermal-magnetic protection arrangement combines two complementary overcurrent protection functions. The thermal element responds to sustained overload conditions that can cause excessive heating in conductors and electrical equipment. The magnetic element responds to sufficiently high short-circuit currents, providing rapid tripping when the applicable operating threshold is reached.

ABB's Protecta Power selection literature identifies the 40 A single-pole A1N125 outgoing MCCB with a 25 kA breaking-capacity classification. This provides a useful reference when comparing outgoing protective devices within the ABB Protecta Power range. However, the applicable breaking capacity must always be checked at the installation's operational voltage and against the exact manufacturer's circuit breaker data before specification.

The LSC L3 designation is an important part of the EPX-A1C-040L3 product reference. ABB offers corresponding 40 A single-pole outgoing variants identified as EPX-A1C-040L1, EPX-A1C-040L2 and EPX-A1C-040L3. These variants allow the required connection arrangement to be specified for the intended outgoing position. They should not be treated as interchangeable without confirming the approved panelboard configuration.

The ABB Protecta Power outgoing MCCB system uses dedicated mounting and cover components to integrate protective devices into the finished electrical distribution assembly. ABB's selection literature specifies that an MCCB base plate and cover are required with each outgoing device. The EPX-A1C-040L3 should therefore be considered an outgoing protective device for use within a compatible assembly, rather than a complete enclosed distribution product.

ABB's published Protecta Power information identifies a maximum cable capacity of 50 mm² for A1 single-pole devices. This figure describes the connection capacity of the relevant device arrangement and is not a recommended conductor size for a 40 A circuit. The appropriate cable cross-section must be determined from the connected load, installation method, voltage drop, fault protection requirements and terminal compatibility.

When specifying the EPX-A1C-040L3, the electrical designer must verify the rated operational voltage, short-circuit breaking capacity, protective characteristics, conductor compatibility and panelboard installation requirements. The outgoing circuit breaker must also be coordinated with the upstream protection arrangement where necessary. Installation and commissioning should follow current ABB technical documentation and applicable electrical installation standards.

Typical Applications

  • ABB Protecta Power outgoing electrical distribution circuits.
  • 40 A single-pole MCCB protection within compatible panelboards.
  • Protecta Power assemblies requiring the LSC L3 connection arrangement.
  • Commercial building low-voltage distribution systems.
  • Industrial electrical distribution panelboards.
  • Individual outgoing circuits requiring appropriately specified overcurrent protection.
  • Office and retail electrical installations.
  • Warehouses and logistics facilities.
  • Manufacturing and light industrial premises.
  • Educational and institutional building distribution systems.
  • Electrical switchrooms and sub-distribution assemblies.
  • Professional electrical panel building and switchgear manufacturing.
  • Compatible outgoing MCCB replacement applications.
  • Protecta Power panelboard refurbishment and expansion projects.

Technical Specifications

Product group Protecta Power Devices
Compatible distribution range ABB Protecta Power
ABB order code 1SDA123214R1
Manufacturer product description A1N125 40A 1p + LSC L3 TMA
Product type Moulded case circuit breaker (MCCB) with LSC connection arrangement
Device application Outgoing circuit protection
Rated current 40 A
Number of poles 1P (single-pole)
Circuit breaker family ABB Formula A1N125
Frame family 125 A
Protection technology Thermal-magnetic
Trip designation TMA
Overload protection Thermal trip function
Short-circuit protection Magnetic trip function
Published breaking-capacity classification 25 kA; verify the applicable operational voltage and detailed ABB ratings
Connection arrangement LSC L3
Connection variant L3
Alternative connection variants EPX-A1C-040L1 and EPX-A1C-040L2
Published A1 single-pole maximum cable capacity 50 mm², subject to terminal and installation requirements
Associated mounting components Compatible outgoing MCCB base plate and cover
Operating functionality Manual switching and automatic overcurrent tripping
System type Low-voltage electrical distribution
Application Compatible ABB Protecta Power outgoing circuits

Frequently Asked Questions

What is the ABB EPX-A1C-040L3 used for?

The ABB EPX-A1C-040L3 is a 40 A single-pole thermal-magnetic MCCB with an LSC L3 connection arrangement. It is designed for compatible ABB Protecta Power outgoing distribution circuits and provides overload and short-circuit protection.

What does L3 mean in the ABB EPX-A1C-040L3 product code?

L3 identifies the specified connection variant within ABB's Protecta Power single-pole outgoing MCCB range. ABB also lists EPX-A1C-040L1 and EPX-A1C-040L2 versions. The correct variant should be selected according to the approved panelboard connection arrangement.

What is the current rating and pole configuration of the EPX-A1C-040L3?

The EPX-A1C-040L3 has a 40 A current rating and a single-pole (1P) configuration. It belongs to the ABB Formula A1N125 circuit breaker family. The 125 A frame designation does not change the device's specified 40 A rating.

What is the breaking capacity of the ABB EPX-A1C-040L3?

ABB's Protecta Power selection literature identifies the 40 A single-pole A1N125 outgoing MCCB with a 25 kA breaking-capacity classification. The applicable rated operational voltage and detailed breaking-capacity specification must be verified against the manufacturer's technical documentation before installation.

Does the ABB EPX-A1C-040L3 require a separate base plate and cover?

Yes. ABB's Protecta Power selection literature specifies that an MCCB base plate and cover are required with each outgoing device. The correct accessories must be selected for the panelboard and circuit breaker arrangement. The EPX-A1C-040L3 is not a complete enclosed distribution assembly on its own.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB Protecta Power provides coordinated low-voltage electrical distribution components for commercial and industrial installations. The EPX-A1C-040L3 combines a 40 A single-pole Formula A1N125 circuit breaker with thermal-magnetic protection, a published 25 kA breaking-capacity classification and an LSC L3 connection arrangement, giving electrical contractors and panel builders a clearly identified outgoing protection option for compatible Protecta Power assemblies.