Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-A1C-032L3 (1SDA123213R1) is a 32 A single-pole A1N125 moulded case circuit breaker with thermal-magnetic protection, a specified 25 kA breaking capacity and an LSC L3 configuration for compatible ABB Protecta Power distribution boards.
£194.77
The ABB EPX-A1C-032L3 is a compact and dependable 32 A single-pole moulded case circuit breaker (MCCB) designed to provide reliable overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB A1N125 circuit breaker platform, this protective device is specifically configured for the L3 phase position in compatible ABB Protecta Power distribution assemblies.
As part of the ABB Protecta Power Devices product group, the EPX-A1C-032L3 combines robust circuit protection with a practical design for commercial and industrial electrical installations. Its thermal-magnetic protection mechanism provides protection against sustained overload conditions and short-circuit faults, helping safeguard electrical cables, connected equipment and distribution infrastructure. The product is supplied in an LSC L3 TMA configuration for integration into compatible distribution equipment.
With a rated current of 32 A, a specified 25 kA breaking capacity within the ABB Protecta Power A1N125 range and a single-pole L3 arrangement, the EPX-A1C-032L3 is suitable for outgoing circuit protection in commercial and industrial distribution boards. Its compact moulded case construction and dedicated phase configuration make it a practical solution for electrical contractors, panel builders and building services engineers.
Moulded case circuit breakers such as the ABB EPX-A1C-032L3 protect electrical circuits by interrupting current when an overload or short-circuit fault occurs. The thermal protection element responds to sustained overcurrent conditions, while the magnetic element provides rapid operation during high fault currents. This combination helps reduce the risk of cable damage, electrical equipment failure and disruption to power distribution systems.
The ABB A1N125 platform provides a dependable foundation for low-voltage circuit protection. Within the Protecta Power range, the EPX-A1C-032L3 is configured for the L3 phase position, supporting organised outgoing circuit protection in compatible three-phase distribution assemblies. Its single-pole design enables protection of an individual phase conductor without requiring a multi-pole circuit breaker.
The 32 A rated current makes this device suitable for appropriately designed outgoing feeders and electrical loads. The thermal-magnetic protection system supports reliable fault interruption, while its dedicated L3 configuration simplifies selection for compatible ABB Protecta Power installations. Final circuit protection requirements, fault ratings and installation compatibility should be assessed against the complete electrical distribution system design.
| Product group | Protecta Power Devices |
|---|---|
| Series / platform | ABB A1N125 |
| ABB order code | 1SDA123213R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 32 A |
| Frame rating | 125 A |
| Breaking capacity | 25 kA (specified Protecta Power application) |
| Number of poles | 1 |
| Pole configuration | Single-pole (1P), L3 |
| Connection configuration | LSC |
| Trip configuration | TMA, thermal-magnetic |
| Protection functions | Overload and short-circuit protection |
| Maximum cable capacity | 50 mm² (ABB A1 single-pole arrangement) |
| Mounting type | Compatible ABB Protecta Power distribution assembly |
| Installation accessories | Appropriate MCCB base plate and cover required |
| Application | Low-voltage electrical power distribution |
The ABB EPX-A1C-032L3 is a 32 A single-pole moulded case circuit breaker designed to protect outgoing electrical circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.
The EPX-A1C-032L3 has a 32 A rated current and is listed with a 25 kA breaking capacity in the ABB Protecta Power A1N125 outgoing circuit breaker range. The applicable breaking capacity must be assessed against the installation voltage and distribution assembly configuration.
TMA stands for Thermal-Magnetic Adjustable. Thermal-magnetic protection combines a thermal element for sustained overload conditions with a magnetic element for short-circuit faults. The exact trip adjustment characteristics should be checked against the specific ABB A1N125 trip unit configuration.
The L3 designation identifies the breaker as a single-pole device configured for the L3 phase position in compatible ABB Protecta Power distribution assemblies. The EPX-A1C-032L3 protects an individual outgoing phase circuit and is not a three-pole circuit breaker.
The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. An appropriate MCCB base plate and cover are required, and installation compatibility should be checked against the selected distribution assembly.
ABB circuit protection and power distribution solutions are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage electrical installations. The EPX-A1C-032L3 combines 32 A circuit protection, thermal-magnetic functionality and compatibility with ABB Protecta Power equipment to support reliable power distribution in commercial and industrial environments.