ABB EPX-A1C-025L3 (1SDA123211R1) is a 25 A single-pole A1N125 moulded case circuit breaker with thermal-magnetic adjustable protection, a 25 kA specified breaking capacity and an L3 configuration for compatible ABB Protecta Power distribution boards.
£194.77
The ABB EPX-A1C-025L3 is a compact and reliable 25 A single-pole moulded case circuit breaker (MCCB) designed to provide effective overload and short-circuit protection in low-voltage electrical distribution systems. Based on the established ABB A1N125 circuit breaker platform, this protective device is specifically configured for the L3 phase position in compatible ABB Protecta Power distribution assemblies.
As part of the ABB Protecta Power Devices product group, the EPX-A1C-025L3 combines dependable circuit protection with a practical design for commercial and industrial electrical installations. Its thermal-magnetic adjustable (TMA) trip mechanism provides protection against sustained overload conditions and short-circuit faults, helping protect electrical cables, connected equipment and distribution infrastructure.
With a rated current of 25 A, a 25 kA breaking capacity in the specified ABB Protecta Power application and a single-pole L3 configuration, the EPX-A1C-025L3 is suitable for outgoing circuit protection in compatible distribution boards. Its LSC connection arrangement supports integration into the appropriate ABB distribution assembly, making it a practical choice for electrical contractors, panel builders and building services engineers.
Moulded case circuit breakers such as the ABB EPX-A1C-025L3 protect electrical circuits by automatically interrupting current when an overload or short-circuit fault occurs. The thermal protection element responds to sustained overcurrent conditions, while the magnetic protection element provides rapid operation during high fault currents. This combination helps minimise the risk of cable damage, electrical equipment failure and disruption to power distribution systems.
The ABB A1N125 platform provides a proven foundation for low-voltage circuit protection. Within the Protecta Power range, the EPX-A1C-025L3 is configured for the L3 phase position, enabling organised outgoing circuit protection in compatible three-phase distribution assemblies. Its single-pole design allows protection of an individual phase conductor without requiring a multi-pole breaker.
The 25 A rated current makes this device suitable for appropriately designed outgoing feeders and electrical loads. Its adjustable thermal-magnetic trip characteristics support protection coordination with connected cables and downstream equipment. Correct selection of trip settings, breaking capacity and installation accessories should be based on the electrical installation design and applicable ABB technical guidance.
| Product group | Protecta Power Devices |
|---|---|
| Series / platform | ABB A1N125 |
| ABB order code | 1SDA123211R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated current | 25 A |
| Frame rating | 125 A |
| Breaking capacity | 25 kA (specified Protecta Power application) |
| Number of poles | 1 |
| Pole configuration | Single-pole (1P), L3 |
| Connection configuration | LSC |
| Trip unit | Thermal-magnetic adjustable (TMA) |
| Thermal trip adjustment | 0.7–1 × In |
| Magnetic trip adjustment | 5–10 × In |
| Protection functions | Overload and short-circuit protection |
| Maximum cable capacity | 50 mm² (ABB A1 single-pole arrangement) |
| Mounting type | Compatible ABB Protecta Power distribution assembly |
| Installation accessories | Appropriate MCCB base plate and cover required |
| Application | Low-voltage electrical power distribution |
The ABB EPX-A1C-025L3 is a 25 A single-pole moulded case circuit breaker designed to protect outgoing electrical circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.
The EPX-A1C-025L3 has a 25 A rated current and is listed with a 25 kA breaking capacity in the ABB Protecta Power A1N125 outgoing circuit breaker range. The applicable breaking capacity must be assessed against the installation voltage and distribution assembly configuration.
TMA stands for Thermal-Magnetic Adjustable. The trip mechanism provides thermal protection against sustained overload currents and magnetic protection against short-circuit faults. The specified TMA configuration offers thermal adjustment from 0.7–1 × In and magnetic adjustment from 5–10 × In.
The L3 designation identifies the breaker as a single-pole device configured for the L3 phase position in compatible ABB Protecta Power distribution assemblies. The EPX-A1C-025L3 protects an individual outgoing phase circuit and is not a three-pole circuit breaker.
The breaker is designed for installation within compatible ABB Protecta Power distribution boards, where it provides outgoing circuit protection. An appropriate MCCB base plate and cover are required, and installation compatibility should be checked against the selected distribution assembly.
ABB circuit protection and power distribution solutions are widely specified by electrical engineers, contractors and panel builders for dependable low-voltage electrical installations. The EPX-A1C-025L3 combines 25 A circuit protection, thermal-magnetic adjustable functionality and compatibility with ABB Protecta Power equipment to support safe, reliable power distribution in commercial and industrial environments.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.