1SDA123209R1 ABB EPX-A1B-016L3 Protecta Power A1C125 16A 1-Pole TMA MCCB with L3 Load Side Connector

1SDA123209R1 ABB EPX-A1B-016L3 Protecta Power A1C125 16A 1-Pole TMA MCCB with L3 Load Side Connector

ABB EPX-A1B-016L3 Protecta Power 16 A single-pole Formula A1C125 thermal-magnetic moulded case circuit breaker with 18 kA breaking capacity and L3 load side connector for compatible low-voltage outgoing distribution circuits.

SKU: 1SDA123209R1Alt SKU: EPX-A1B-016L3MPN: 1SDA123209R1
Price
List Price £194.77 ex VAT
Your Price (ex VAT)
£194.77
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.77

Why Choose the ABB EPX-A1B-016L3 16A Single-Pole MCCB with L3 Load Side Connector?

The ABB EPX-A1B-016L3 is a 16 A, single-pole moulded case circuit breaker (MCCB) with an L3 load side connector, designed for outgoing circuit protection within compatible ABB Protecta Power electrical distribution assemblies. Incorporating the ABB Formula A1C125 circuit breaker platform, this device provides thermal-magnetic protection against overloads and short-circuit faults in commercial and industrial low-voltage installations.

Featuring thermal-magnetic protection with the manufacturer's TMA designation, the EPX-A1B-016L3 combines thermal overload protection with magnetic short-circuit tripping. The ABB Protecta Power 16 A single-pole A1C125 configuration is specified with an 18 kA breaking capacity, providing a protective solution for appropriately designed distribution systems where the prospective fault current is within the applicable circuit breaker rating.

With a 16 A rated current, single-pole construction and L3 load side connector (LSC), the EPX-A1B-016L3 supports integration into compatible Protecta Power outgoing circuit arrangements. Its 125 A frame class provides a compact protective solution for individual circuits requiring the designated L3 connection configuration.

Key Advantages

  • 16 A rated current for individual outgoing circuit protection.
  • Single-pole configuration suitable for compatible single-phase distribution circuits.
  • ABB Formula A1C125 platform provides established moulded case circuit breaker technology.
  • 18 kA breaking capacity for the specified 16 A single-pole Protecta Power configuration.
  • Thermal-magnetic protection against sustained overloads and short-circuit faults.
  • L3 load side connector supports the designated phase connection within compatible distribution panelboards.
  • Compact protective device for ABB Protecta Power electrical distribution assemblies.
  • Purpose-designed outgoing circuit protection solution for electrical contractors and panel builders.

Key Features

  • ABB Protecta Power Devices range.
  • 16 A single-pole MCCB.
  • ABB Formula A1C125 circuit breaker family.
  • 125 A frame class.
  • 18 kA breaking capacity for the specified single-pole device.
  • Thermal-magnetic trip protection with TMA designation.
  • Thermal overload protection for sustained overcurrent conditions.
  • Magnetic short-circuit protection for high fault current conditions.
  • LSC load side connector in the L3 configuration.
  • Manual switching and circuit breaker resetting.
  • Maximum A1 single-pole cable capacity: 50 mm², subject to terminal suitability.
  • Designed for outgoing circuit installation within compatible ABB Protecta Power panelboards.
  • ABB manufacturer order code 1SDA123209R1.

Reliable Thermal-Magnetic Protection for Low-Voltage Distribution

The ABB EPX-A1B-016L3 protects outgoing electrical circuits against excessive current caused by overloads and short-circuit faults. Its thermal protection mechanism responds to sustained overcurrent conditions, while magnetic protection provides rapid circuit interruption during sufficiently high fault currents. These complementary functions help protect electrical conductors, connected equipment and distribution infrastructure from damaging overcurrent conditions.

The ABB Formula A1C125 platform provides a compact protective solution for compatible Protecta Power panelboards. The EPX-A1B-016L3 combines a 16 A protective rating with an L3 load side connector for the designated outgoing connection arrangement. Electrical designers should verify the prospective short-circuit current, operating voltage, conductor sizing, terminal compatibility and distribution assembly requirements before installation.

Typical Applications

  • ABB Protecta Power outgoing circuit installations.
  • Commercial building electrical distribution panelboards.
  • Industrial low-voltage electrical distribution systems.
  • Single-phase outgoing circuits connected to L3 within compatible three-phase distribution assemblies.
  • Electrical plant rooms and building services infrastructure.
  • Manufacturing facilities and industrial workshops.
  • Warehouses, offices and commercial premises.
  • Panel building projects requiring 16 A single-pole MCCB protection with an L3 load side connector.

Technical Specifications

Product series Protecta Power / Formula A1C125
ABB order code 1SDA123209R1
Product type Moulded case circuit breaker with load side connector
Rated current 16 A
Number of poles 1
Circuit breaker family A1C125
Frame current class 125 A
Breaking capacity 18 kA, subject to applicable operating voltage and installation conditions
Trip technology Thermal-magnetic
Manufacturer trip designation TMA
Overload protection Thermal
Short-circuit protection Magnetic
Connector designation LSC
Phase designation L3
Maximum A1 single-pole cable capacity 50 mm², subject to terminal configuration
Connection arrangement Single-pole with L3 load side connector
Installation Compatible ABB Protecta Power outgoing circuit assembly
Product group Protecta Power Devices
Application Low-voltage outgoing circuit protection

Frequently Asked Questions

What is the ABB EPX-A1B-016L3 used for?

The ABB EPX-A1B-016L3 is a 16 A single-pole thermal-magnetic moulded case circuit breaker with an L3 load side connector, designed for outgoing circuit protection within compatible ABB Protecta Power electrical distribution assemblies.

What is the current rating of the EPX-A1B-016L3?

The EPX-A1B-016L3 has a 16 A rated current and belongs to the ABB Formula A1C125 circuit breaker family, which has a 125 A frame class. The frame designation does not change the device's 16 A protective rating.

What is the breaking capacity of the EPX-A1B-016L3?

The ABB Protecta Power 16 A single-pole A1C125 configuration is specified with an 18 kA breaking capacity. The applicable breaking capacity must be checked against the installation's operating voltage and prospective short-circuit current.

What do TMA, LSC and L3 mean?

TMA identifies the thermal-magnetic trip arrangement, LSC identifies the load side connector and L3 specifies the designated phase connection. These designations describe the protection and connection configuration of the EPX-A1B-016L3.

What is the difference between the EPX-A1B-016L3 and the L1 or L2 versions?

The EPX-A1B-016L1, EPX-A1B-016L2 and EPX-A1B-016L3 are 16 A single-pole Protecta Power MCCB configurations designated for different phase connection positions. The L3 version is intended for the designated L3 arrangement, while the L1 and L2 versions correspond to their respective connection positions.

Trusted by Electrical Contractors and Panel Builders

ABB Formula circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with dependable solutions for low-voltage circuit protection. The EPX-A1B-016L3 combines a 16 A single-pole protective rating, A1C125 thermal-magnetic technology and an L3 load side connector to support reliable outgoing circuit protection within compatible commercial and industrial distribution assemblies.