1SDA123208R1 ABB EPX-A1C-125L2 Protecta Power 125A 1-Pole A1N125 MCCB with L2 Load-Side Connection

1SDA123208R1 ABB EPX-A1C-125L2 Protecta Power 125A 1-Pole A1N125 MCCB with L2 Load-Side Connection

ABB EPX-A1C-125L2 Protecta Power 125 A single-pole Formula A1N125 thermal-magnetic outgoing MCCB assembly, order code 1SDA123208R1, with a 25 kA breaking capacity listed in ABB’s Protecta Power selection information and an L2-position load-side connection arrangement for compatible electrical distribution panelboards.

SKU: 1SDA123208R1Alt SKU: EPX-A1C-125L2MPN: 1SDA123208R1
Price
List Price £210.79 ex VAT
Your Price (ex VAT)
£210.79
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £210.79
Trade pricing is personalised to your account

Manufacturer Lead Time

£210.79

Why Choose the ABB EPX-A1C-125L2 125A Single-Pole MCCB?

The ABB EPX-A1C-125L2 is a 125 A single-pole moulded case circuit breaker (MCCB) assembly designed for outgoing circuit protection in compatible ABB Protecta Power electrical distribution panelboards. Based on the ABB Formula A1N125 circuit breaker platform, the device combines thermal-magnetic overload and short-circuit protection with an L2-position load-side connection (LSC) arrangement for integration into the Protecta Power distribution system.

Part of the ABB Protecta Power Devices product group, the EPX-A1C-125L2 is identified by ABB order code 1SDA123208R1. Its manufacturer product description is EPX-A1C-125L2 A1N125 125A 1p+ LSC L2 TMA. The assembly is intended for installations requiring a manufacturer-specified 125 A outgoing protective device with a single-pole configuration and a dedicated L2 connection position.

ABB's Protecta Power selection information identifies the corresponding 125 A single-pole Formula A1N125 outgoing MCCB within its 25 kA thermal-magnetic circuit breaker range. The EPX-A1C-125L2 is specifically configured for the L2 connection position, with related L1 and L3 variants available for alternative outgoing circuit positions. This supports the selection of appropriately rated and configured protective devices for compatible Protecta Power assemblies.

Key Advantages

  • Purpose-designed 125 A outgoing MCCB for compatible ABB Protecta Power distribution panelboards.
  • Uses the established ABB Formula A1N125 circuit breaker platform.
  • Single-pole (1P) configuration for suitable phase conductor protection applications.
  • Provides thermal-magnetic overload and short-circuit protection.
  • 25 kA breaking capacity listed for the corresponding A1N125 outgoing device in ABB's Protecta Power selection information.
  • L2-specific connection arrangement for the appropriate outgoing circuit position.
  • Includes the specified LSC load-side connection arrangement.
  • Provides a manufacturer-defined protective device configuration for compatible panelboard installations.
  • Supports coordinated outgoing circuit protection in commercial and industrial distribution systems.
  • Suitable for electrical circuits requiring an appropriately specified 125 A protective device.
  • Part of ABB's coordinated Protecta Power outgoing MCCB range.
  • Related L1 and L3 variants available for alternative connection positions.
  • Clearly identified by ABB order code 1SDA123208R1 for accurate specification and procurement.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-A1C-125L2 outgoing circuit breaker assembly.
  • 125 A rated current.
  • Single-pole (1P) circuit breaker configuration.
  • ABB Formula A1N125 circuit breaker platform.
  • 125 A frame family.
  • Thermal-magnetic protection technology.
  • TMA trip designation in the manufacturer product description.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit fault conditions.
  • 25 kA breaking capacity identified for the corresponding A1N125 outgoing device in ABB's Protecta Power selection guide.
  • L2 connection position.
  • LSC load-side connection arrangement.
  • Designed for compatible ABB Protecta Power outgoing distribution ways.
  • ABB lists a maximum cable capacity of 50 mm² for its A1 single-pole outgoing device range, subject to terminal suitability.
  • Compatible MCCB base plate and cover required for the completed outgoing installation.
  • Related L1 and L3 connection variants available.
  • Manufacturer model EPX-A1C-125L2 and ABB order code 1SDA123208R1.

125A Thermal-Magnetic Protection with a 25kA Breaking Capacity

The ABB EPX-A1C-125L2 is designed for outgoing electrical circuits requiring a 125 A protective device within a compatible Protecta Power distribution assembly. Its Formula A1N125 platform provides thermal-magnetic protection, combining overload and short-circuit response within a single moulded case circuit breaker. The device must be selected according to the circuit design, including the intended load, conductor characteristics and prospective fault current.

The thermal protection element responds to sustained overcurrent conditions associated with circuit overloads. The magnetic protection element responds to higher fault currents associated with short circuits. Together, these functions provide circuit protection when the MCCB is correctly specified, installed and coordinated with the connected conductors and other protective devices.

ABB's Protecta Power selection information identifies the 125 A single-pole A1N125 outgoing MCCB within its 25 kA breaking capacity range. The applicable breaking capacity must be considered alongside the system operating voltage and prospective short-circuit current at the installation point. The device's precise interruption ratings and applicable conditions must be verified from the relevant ABB technical documentation.

The manufacturer product description includes the TMA designation, identifying the specified thermal-magnetic trip arrangement. ABB's Protecta Power technical information describes thermal adjustment from 0.7 to 1 × In and magnetic adjustment from 5 to 10 × In for applicable TMA devices. The actual adjustment provisions and trip characteristics of the supplied EPX-A1C-125L2 must nevertheless be confirmed against its specific device documentation before protection settings are selected.

The A1N125 designation identifies a 125 A frame family, and the EPX-A1C-125L2 is itself rated at 125 A. This is the highest nominal current rating within the A1N125 single-pole outgoing device range listed in ABB's Protecta Power selection information. The actual circuit design must still account for conductor current-carrying capacity, installation conditions, overload protection, fault protection and the required protective coordination.

L2 Load-Side Connection and Protecta Power Installation

The L2 designation identifies the specified connection position for this outgoing MCCB assembly. ABB also lists the EPX-A1C-125L1 and EPX-A1C-125L3 as corresponding 125 A single-pole variants for the L1 and L3 positions. These are separate manufacturer references and should be selected according to the intended outgoing way and ABB's approved panelboard configuration.

The product description also includes LSC, referring to the associated load-side connection arrangement. This forms part of the manufacturer-defined outgoing device configuration. Correct installation requires suitable mechanical mounting, electrical contact, conductor termination and protective covering within the distribution assembly.

ABB's Protecta Power selection information specifies that an MCCB base plate and cover are required with each outgoing device. These accessories provide the appropriate mounting and front-cover arrangement for the completed panelboard installation. The correct components must be selected for the actual circuit breaker and distribution assembly, and their inclusion in the ordered package should be confirmed before installation.

For the A1 single-pole outgoing device range, ABB lists a maximum cable capacity of 50 mm². This is a general manufacturer selection-guide value and must not be interpreted as confirmation that every 50 mm² conductor is suitable for a 125 A circuit. Actual cable sizing depends on conductor material, installation method, current-carrying capacity, ambient conditions, grouping factors, voltage drop, fault protection and the compatibility of the device terminals.

Related ABB Protecta Power outgoing devices include the EPX-A1C-100L2 rated at 100 A and the EPX-A1C-080L2 rated at 80 A. These provide alternative current ratings for compatible L2 outgoing positions. The appropriate device should always be selected from the electrical design rather than substituted solely because it belongs to the same Formula A1 family.

Typical Applications

  • ABB Protecta Power outgoing circuit protection installations.
  • 125 A single-pole MCCB arrangements in compatible distribution panelboards.
  • Commercial building low-voltage electrical distribution systems.
  • Industrial electrical distribution assemblies requiring suitably rated outgoing protection.
  • Single-phase outgoing circuits within appropriately designed three-phase distribution systems.
  • Electrical panelboards requiring an L2-position outgoing protective device.
  • Circuits requiring thermal-magnetic overload and short-circuit protection.
  • Distribution systems where a suitably rated 25 kA outgoing MCCB is specified.
  • Electrical switchrooms and building services distribution installations.
  • Switchboard manufacturing and electrical panel-building projects.
  • Compatible Protecta Power panelboard extensions and circuit additions.
  • Replacement of a correctly matched ABB Protecta Power outgoing protective device.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power
ABB order code 1SDA123208R1
Manufacturer product description EPX-A1C-125L2 A1N125 125A 1p+ LSC L2 TMA
Product type Outgoing moulded case circuit breaker assembly
Product category Low-voltage circuit protection devices
Device family ABB Formula A1
Device platform A1N125
Frame size 125 A
Rated current 125 A
Number of poles 1
Pole configuration 1P
Breaking capacity listed in ABB Protecta Power selection information 25 kA
Protection technology Thermal-magnetic
Manufacturer trip designation TMA
Protection functions Overload and short-circuit protection
Connection position L2
Connection arrangement LSC (load-side connection)
Installation position Outgoing circuit
Compatible product family ABB Protecta Power
Maximum cable capacity listed for A1 single-pole outgoing devices 50 mm², subject to terminal configuration
Associated installation accessories Compatible MCCB base plate and cover
Related L1 variant EPX-A1C-125L1
Related L3 variant EPX-A1C-125L3
Electrical system Low-voltage electrical distribution
Primary function Outgoing circuit overload and short-circuit protection

Frequently Asked Questions

What is the ABB EPX-A1C-125L2 used for?

The ABB EPX-A1C-125L2 is a 125 A single-pole outgoing MCCB assembly designed for compatible ABB Protecta Power electrical distribution panelboards. It provides thermal-magnetic overload and short-circuit protection and is configured for the L2 connection position.

What is the breaking capacity of the ABB EPX-A1C-125L2?

ABB's Protecta Power selection information lists the corresponding 125 A single-pole Formula A1N125 outgoing MCCB within its 25 kA breaking capacity range. The relevant operating voltage, prospective fault current and device documentation must be checked before specification.

What do A1N125, L2 and LSC mean in the EPX-A1C-125L2 description?

A1N125 identifies the ABB Formula A1 circuit breaker platform and 125 A frame family. L2 identifies the specified connection position, while LSC refers to the associated load-side connection arrangement. The EPX-A1C-125L2 has a rated current of 125 A.

Does the ABB EPX-A1C-125L2 require additional installation accessories?

ABB's Protecta Power selection information states that a compatible MCCB base plate and cover are required with each outgoing device. The correct accessories must be selected for the intended panelboard arrangement, and installation must follow the applicable ABB assembly instructions.

What is the ABB order code for the EPX-A1C-125L2?

The ABB order code is 1SDA123208R1, and the model reference is EPX-A1C-125L2. Its manufacturer product description is EPX-A1C-125L2 A1N125 125A 1p+ LSC L2 TMA, within the ABB Protecta Power Devices product group.

Trusted ABB Protecta Power Circuit Protection Solutions

ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage protective devices, panelboards and installation accessories. The EPX-A1C-125L2 combines a 125 A single-pole Formula A1N125 thermal-magnetic circuit breaker with an L2-specific load-side connection arrangement, supporting outgoing circuit protection within compatible Protecta Power electrical distribution assemblies.