1SDA123205R1 ABB EPX-A1C-080L2 80A 1-Pole A1N125 MCCB LSC L2 Protecta Power

1SDA123205R1 ABB EPX-A1C-080L2 80A 1-Pole A1N125 MCCB LSC L2 Protecta Power

ABB EPX-A1C-080L2 is an 80 A single-pole Formula A1N125 thermal-magnetic MCCB configuration with a 25 kA Protecta Power breaking-capacity classification and L2-specific LSC connection arrangement for compatible low-voltage distribution panelboards.

SKU: 1SDA123205R1Alt SKU: EPX-A1C-080L2MPN: 1SDA123205R1
Price
List Price £204.11 ex VAT
Your Price (ex VAT)
£204.11
Manufacturer Lead Time Estimated Delivery 4 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £204.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£204.11

ABB EPX-A1C-080L2 80A Single-Pole A1N125 MCCB with LSC L2 Connection

The ABB EPX-A1C-080L2 is an 80 A single-pole moulded case circuit breaker (MCCB) configuration designed for compatible ABB Protecta Power low-voltage distribution panelboards. Based on the ABB Formula A1N125 circuit breaker platform, this outgoing protective device incorporates a designated LSC L2 connection arrangement and thermal-magnetic protection.

Part of the ABB Protecta Power Devices range, the EPX-A1C-080L2 provides overload and short-circuit protection for individual outgoing circuits. Its 80 A rated current, compact single-pole construction and 125 A frame family make it suitable for appropriately designed commercial and industrial distribution installations.

ABB lists the A1N125 80 A single-pole outgoing breaker within its 25 kA Protecta Power device range. The underlying Formula A1N125 breaker uses fixed thermal-magnetic protection, providing a thermal response to sustained overload conditions and a magnetic response to short-circuit faults. The Protecta Power assembly designation includes TMA, so the exact protective characteristics should be confirmed from the supplied breaker documentation.

Identified by ABB order code 1SDA123205R1, this L2-specific configuration supports accurate selection of outgoing protective devices for ABB Protecta Power panelboard assemblies.

Key Advantages

  • 80 A rated current: Provides protection for suitably designed outgoing distribution circuits.
  • Single-pole configuration: Designed for switching and protecting one phase conductor.
  • ABB Formula A1N125 platform: Uses established ABB moulded case circuit breaker technology.
  • Thermal-magnetic protection: Combines overload and short-circuit protective functions.
  • 25 kA catalogue classification: Listed within ABB's Protecta Power 25 kA A1N125 outgoing device range.
  • L2-specific arrangement: Identifies the correct configuration for the designated L2 outgoing position.
  • LSC connection: Supports the specified Protecta Power outgoing connection arrangement.
  • Compact construction: Suitable for space-conscious electrical distribution board layouts.
  • Manufacturer-matched solution: Supports coordinated selection of protective devices for compatible ABB panelboards.
  • Practical maintenance: Clear model and order-code identification assists with replacement and refurbishment projects.

Key Features

  • ABB EPX-A1C-080L2 outgoing MCCB configuration.
  • 80 A rated current.
  • 1-pole (1P) circuit breaker construction.
  • ABB Formula A1N125 circuit breaker family.
  • 125 A frame designation.
  • Thermal-magnetic overcurrent protection.
  • Thermal protection against sustained overloads.
  • Magnetic protection against short-circuit faults.
  • 25 kA Protecta Power outgoing device classification.
  • L2 phase-position designation.
  • LSC connection configuration.
  • Manual circuit breaker switching.
  • Designed for compatible ABB Protecta Power distribution panelboards.
  • Suitable for commercial and industrial low-voltage distribution applications.
  • Manufacturer order code 1SDA123205R1.

Reliable Thermal-Magnetic Protection for 80A Outgoing Circuits

The ABB EPX-A1C-080L2 is designed to provide dependable overcurrent protection within compatible Protecta Power distribution systems. By combining the Formula A1N125 circuit breaker platform with a designated outgoing connection arrangement, it supports professional panelboard construction and straightforward device identification.

The thermal protection element responds to sustained overload currents that can cause excessive heating of cables and connected equipment. Its operation is based on the protective characteristics of the supplied breaker, helping protect the circuit when the device is correctly selected for the conductor and operating conditions.

The magnetic protection element responds to short-circuit currents, providing rapid interruption when fault conditions reach the device's operating threshold. Together, these functions offer a conventional thermal-magnetic protection solution without requiring an electronic trip unit.

ABB identifies the underlying 80 A A1N125 single-pole breaker as a fixed thermal-magnetic device. Although the Protecta Power product description uses the term TMA, installers should verify the actual trip characteristics from the manufacturer's documentation rather than assuming adjustable settings are available.

The L2 designation distinguishes this configuration from the corresponding L1 and L3 versions. Correct phase-position selection is important for matching the outgoing protective device to the panelboard's internal connection arrangement. The LSC designation forms part of this specified assembly configuration.

ABB's Protecta Power documentation identifies a maximum cable capacity of 50 mm² for A1 single-pole outgoing devices. The actual conductor size permitted depends on the fitted terminals, conductor type, installation conditions and relevant electrical design requirements.

Installation of outgoing MCCBs within Protecta Power assemblies also requires the appropriate MCCB base plate and cover. These components must be selected for the relevant panelboard and device configuration, and their inclusion should not be assumed unless confirmed in the supplied assembly.

Before installation, the protective device must be checked against the prospective short-circuit current, system voltage, conductor current-carrying capacity and upstream protection. The manufacturer's published breaking-capacity values must be applied at the relevant operating voltage.

For new installations, refurbishment and replacement projects, the EPX-A1C-080L2 offers a clearly identified 80 A L2 outgoing MCCB solution within the ABB Protecta Power system.

Typical Applications

  • ABB Protecta Power outgoing circuit protection.
  • 80 A single-pole electrical distribution circuits.
  • L2-position outgoing ways in compatible panelboards.
  • Commercial building electrical distribution.
  • Industrial low-voltage switchgear assemblies.
  • Warehouses and logistics facilities.
  • Office buildings and retail developments.
  • Building services electrical installations.
  • Suitable fixed equipment supply circuits.
  • Distribution board refurbishment and maintenance.
  • Electrical panel building and assembly projects.
  • Replacement of compatible ABB Formula A1 outgoing protective devices.

Technical Specifications

Product group Protecta Power Devices
Product model EPX-A1C-080L2
ABB order code 1SDA123205R1
Product type Outgoing moulded case circuit breaker configuration
Circuit breaker series ABB Formula A1
Breaker designation A1N125
Frame rating 125 A
Rated current 80 A
Number of poles 1
Pole arrangement Single-pole (1P)
Breaking-capacity classification 25 kA in the ABB Protecta Power catalogue; applicable voltage conditions must be verified
Protection technology Thermal-magnetic
Protecta Power product designation TMA
Underlying A1N125 breaker trip type Fixed thermal-magnetic (TMF)
Overload protection Thermal
Short-circuit protection Magnetic
Phase-position designation L2
Connection arrangement LSC
Switching operation Manual
Maximum stated A1 single-pole cable capacity 50 mm², subject to the terminal and conductor arrangement
ABB underlying protective device reference 1SDA066693R1
Compatible distribution system ABB Protecta Power
Related L1 variant EPX-A1C-080L1
Related L3 variant EPX-A1C-080L3
Primary application Outgoing circuit protection in compatible low-voltage distribution panelboards

Frequently Asked Questions

What is the ABB EPX-A1C-080L2 used for?

The ABB EPX-A1C-080L2 is an 80 A single-pole outgoing MCCB configuration designed for the L2 position in compatible ABB Protecta Power low-voltage distribution panelboards.

What is the rated current of the EPX-A1C-080L2?

The EPX-A1C-080L2 has a rated current of 80 A. It belongs to the ABB Formula A1N125 circuit breaker family, which has a 125 A frame designation.

Is the EPX-A1C-080L2 a single-pole circuit breaker?

Yes. The EPX-A1C-080L2 is a single-pole (1P) MCCB configuration designed to protect and switch one phase conductor.

What does L2 mean in the EPX-A1C-080L2 model number?

L2 identifies the designated phase-position configuration within the ABB Protecta Power outgoing device range. Separate L1 and L3 variants are available for their respective positions.

What is the breaking capacity of the EPX-A1C-080L2?

ABB lists the 80 A A1N125 single-pole outgoing device in its 25 kA Protecta Power range. The applicable breaking capacity must be confirmed at the installation's operating voltage.

Does the EPX-A1C-080L2 use thermal-magnetic protection?

Yes. The ABB Formula A1N125 breaker uses thermal-magnetic protection against overload and short-circuit conditions. ABB identifies the underlying 80 A protective device as a fixed thermal-magnetic breaker, while the Protecta Power assembly description uses the TMA designation.

What does LSC mean in the ABB EPX-A1C-080L2 description?

LSC identifies the connection arrangement specified for this Protecta Power outgoing device configuration. The installation must use the correct arrangement for the selected panelboard.

What is the maximum cable capacity for this A1 single-pole outgoing device?

ABB specifies a maximum cable capacity of 50 mm² for A1 single-pole outgoing devices in the Protecta Power system. The actual permissible conductor size depends on the terminals, cable construction and installation requirements.

What is the difference between EPX-A1C-080L1, EPX-A1C-080L2 and EPX-A1C-080L3?

These are corresponding 80 A single-pole ABB A1N125 outgoing MCCB configurations for different phase positions. The L1, L2 and L3 suffixes identify the intended connection positions within compatible Protecta Power panelboards.

Trusted by Electrical Contractors and Panel Builders

ABB Protecta Power outgoing circuit breakers provide a coordinated approach to low-voltage distribution protection. The EPX-A1C-080L2 combines an 80 A ABB Formula A1N125 protective device with a designated L2 connection configuration, supporting electrical contractors and panel builders in creating organised, dependable distribution assemblies.