ABB EPX-A1C-063L2 is a 63 A single-pole Formula A1N125 thermal-magnetic MCCB configuration with a 25 kA breaking-capacity classification and L2-specific LSC connection arrangement for compatible ABB Protecta Power outgoing circuits.

SKU: 1SDA123203R1Alt SKU: EPX-A1C-063L2MPN: 1SDA123203R1
Price
List Price £202.76 ex VAT
Your Price (ex VAT)
£202.76
Manufacturer Lead Time Estimated Delivery 4 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £202.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£202.76

Why Choose the ABB EPX-A1C-063L2 63A Single-Pole MCCB?

The ABB EPX-A1C-063L2 is a 63 A, single-pole moulded case circuit breaker (MCCB) from the ABB Formula A1N125 family, configured for the L2 outgoing position within compatible ABB Protecta Power distribution panelboards. Supplied with an LSC connection arrangement and thermal-magnetic protection, this device provides a coordinated solution for protecting individual outgoing electrical circuits.

Designed for professional low-voltage power distribution, the EPX-A1C-063L2 combines a compact 125 A frame family with a 63 A rated current. ABB identifies the A1N125 single-pole 63 A circuit breaker with a 25 kA breaking-capacity classification in its Protecta Power outgoing device selection tables. The applicable breaking capacity must always be checked against the installation voltage and prospective fault current.

The ABB Formula A1 platform uses thermal-magnetic protection to respond to sustained overloads and short-circuit conditions. The 63 A A1N125 protective device is identified in ABB documentation as a fixed thermal-magnetic (TMF) breaker, while the Protecta Power assembly description uses the designation TMA. For accurate commissioning and replacement selection, the protective characteristics should be taken from the supplied device marking and its ABB technical documentation.

Identified by ABB order code 1SDA123203R1, the EPX-A1C-063L2 belongs to the ABB Protecta Power Devices range. Its L2-specific configuration helps electrical contractors and panel builders select the correct outgoing protective device and connection arrangement for compatible distribution assemblies.

Key Advantages

  • 63 A rated current: Provides circuit protection for suitably designed outgoing electrical distribution circuits.
  • Single-pole construction: Designed to protect and switch one phase conductor.
  • ABB Formula A1N125 platform: Uses ABB's established compact moulded case circuit breaker family.
  • 25 kA breaking-capacity classification: Provides the manufacturer-listed fault-interruption capability for the specified A1N125 outgoing device range, subject to voltage conditions.
  • Thermal-magnetic protection: Combines overload and short-circuit protective functions.
  • L2-specific configuration: Identifies the device arrangement for the second phase position in compatible Protecta Power assemblies.
  • LSC connection arrangement: Supports the designated outgoing circuit connection within the panelboard system.
  • Compact protective device: Suitable for installations where efficient use of distribution board space is important.
  • Protecta Power compatibility: Designed for integration into suitable ABB Protecta Power distribution assemblies.
  • Coordinated manufacturer selection: Helps simplify the specification of outgoing protective devices and associated panelboard components.

Key Features

  • ABB EPX-A1C-063L2 outgoing circuit breaker assembly.
  • 63 A rated current.
  • Single-pole (1P) construction.
  • ABB Formula A1N125 circuit breaker family.
  • 125 A frame family designation.
  • 25 kA manufacturer-listed breaking-capacity classification for the A1N125 single-pole outgoing range.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit faults.
  • L2 phase-position designation.
  • LSC connection configuration.
  • Manual circuit breaker operation.
  • Compact moulded case construction.
  • Designed for compatible ABB Protecta Power outgoing circuit arrangements.
  • Suitable for commercial and industrial low-voltage distribution systems.
  • Part of the ABB Protecta Power Devices product group.

Reliable 63A Outgoing Circuit Protection for ABB Protecta Power

Low-voltage distribution systems require protective devices capable of interrupting abnormal electrical currents before they cause unacceptable damage to cables, equipment or the installation. The ABB EPX-A1C-063L2 provides a manufacturer-specified 63 A single-pole protective device for compatible Protecta Power outgoing circuits.

The ABB Formula A1N125 platform incorporates thermal-magnetic protection. Its thermal function responds to sustained overcurrent conditions, while the magnetic function provides protection against short-circuit faults. Together, these functions support safe circuit operation when the breaker is correctly selected and installed.

ABB identifies the underlying 63 A A1N125 single-pole circuit breaker as a fixed thermal-magnetic device. Although the Protecta Power product description includes the abbreviation TMA, installers should not assume that the actual 63 A breaker provides adjustable trip settings without checking its markings and technical documentation.

The L2 designation is particularly important when selecting outgoing devices for the Protecta Power system. ABB offers corresponding L1, L2 and L3 configurations so that the correct protective device arrangement can be selected for the intended phase position. These variants should not be treated as interchangeable without confirming the panelboard connection requirements.

The LSC connection arrangement forms part of the specified Protecta Power outgoing device configuration. The correct installation must also incorporate the appropriate ABB mounting components, base plate and cover where required by the selected panelboard assembly.

ABB's Protecta Power documentation identifies a maximum cable capacity of 50 mm² for A1 single-pole outgoing devices. This is a system-level maximum rather than a guarantee that every conductor type or termination method is suitable. The permissible cable size must be checked against the actual terminals, conductor construction and installation conditions.

The 25 kA breaking-capacity classification must be considered alongside the circuit's prospective short-circuit current and operating voltage. Protective device selection should also account for conductor current-carrying capacity, installation method, operating temperature and coordination with upstream protection.

By combining a compact ABB Formula circuit breaker with the designated Protecta Power outgoing connection configuration, the EPX-A1C-063L2 provides a practical solution for professional distribution board assembly, maintenance and replacement projects.

Typical Applications

  • ABB Protecta Power outgoing circuit protection.
  • 63 A single-phase distribution circuits.
  • L2-position outgoing ways in compatible distribution panelboards.
  • Commercial low-voltage electrical distribution systems.
  • Industrial power distribution assemblies.
  • Office buildings and retail premises.
  • Warehouses and logistics facilities.
  • Building services electrical distribution.
  • Distribution board refurbishment and protective device replacement.
  • Electrical panel building and switchgear assembly.
  • Suitable fixed equipment supply circuits.
  • Projects requiring compact single-pole MCCB protection.

Technical Specifications

Product group Protecta Power Devices
Product range Protecta Power
ABB order code 1SDA123203R1
Product type Outgoing moulded case circuit breaker assembly
Circuit breaker family ABB Formula A1
Breaker designation A1N125
Frame family 125 A
Rated current 63 A
Number of poles 1
Pole configuration Single-pole (1P)
Breaking-capacity classification 25 kA, subject to the manufacturer's specified operating voltage
Protection technology Thermal-magnetic
Protecta Power catalogue trip designation TMA
Underlying ABB A1N125 protective device Fixed thermal-magnetic (TMF)
Overload protection Thermal
Short-circuit protection Magnetic
Phase-position designation L2
Connection configuration LSC
Switching operation Manual
Maximum stated A1 single-pole cable capacity 50 mm², subject to terminal and conductor arrangement
Compatible distribution system ABB Protecta Power
Associated protective device reference 1SDA068766R1
Related L1 configuration EPX-A1C-063L1
Related L3 configuration EPX-A1C-063L3
Application Outgoing circuit protection in low-voltage distribution panelboards

Frequently Asked Questions

What is the ABB EPX-A1C-063L2 used for?

The ABB EPX-A1C-063L2 is a 63 A single-pole outgoing MCCB configuration designed for the L2 position in compatible ABB Protecta Power low-voltage distribution panelboards.

What is the current rating of the EPX-A1C-063L2?

The EPX-A1C-063L2 has a 63 A rated current and belongs to the ABB Formula A1N125 circuit breaker family, which uses a 125 A frame designation.

Is the EPX-A1C-063L2 a single-pole or three-pole circuit breaker?

The EPX-A1C-063L2 is a single-pole (1P) circuit breaker arrangement intended for protecting and switching one phase conductor.

What does L2 mean in the EPX-A1C-063L2 product code?

L2 identifies the designated phase-position configuration within the ABB Protecta Power outgoing device range. Corresponding L1 and L3 versions are available for other phase positions.

What is the breaking capacity of the EPX-A1C-063L2?

ABB lists the A1N125 63 A single-pole outgoing device within its 25 kA Protecta Power range. The applicable breaking capacity must be verified at the installation's operating voltage.

Does the EPX-A1C-063L2 use thermal-magnetic protection?

Yes. The ABB A1N125 protective device uses thermal-magnetic protection for overload and short-circuit conditions. ABB identifies the underlying 63 A breaker as a fixed thermal-magnetic device, although the Protecta Power assembly description includes the TMA designation.

What does LSC mean in the product description?

LSC is the connection configuration identified in the ABB Protecta Power product description. It relates to the specified outgoing device arrangement and should be matched to the appropriate panelboard installation requirements.

What cable size can be connected to an A1 single-pole outgoing device?

ABB's Protecta Power documentation identifies a maximum cable capacity of 50 mm² for A1 single-pole outgoing devices. The actual permissible conductor size depends on the terminals, cable type and installation conditions.

What is the difference between EPX-A1C-063L1, EPX-A1C-063L2 and EPX-A1C-063L3?

All three products are 63 A single-pole ABB A1N125 outgoing MCCB configurations. Their principal distinction is the designated phase position: L1, L2 or L3. The correct version must be selected for the intended Protecta Power panelboard arrangement.

Trusted by Electrical Contractors and Panel Builders

ABB Protecta Power outgoing circuit breakers provide a coordinated approach to low-voltage distribution protection. The EPX-A1C-063L2 combines a 63 A ABB Formula A1N125 protective device with an L2-specific connection configuration, helping electrical contractors and panel builders select suitable components for professionally assembled distribution systems.