ABB EPX-A1C-040L2 Protecta Power 40 A single-pole Formula A1N125 thermal-magnetic moulded case circuit breaker with 25 kA breaking capacity and L2 load side connector for compatible low-voltage outgoing distribution circuits.
£194.77
The ABB EPX-A1C-040L2 is a 40 A, single-pole moulded case circuit breaker (MCCB) with an L2 load side connector, designed for outgoing circuit protection in compatible ABB Protecta Power electrical distribution assemblies. Incorporating the ABB Formula A1N125 circuit breaker platform, this device provides thermal-magnetic protection against overloads and short-circuit faults in commercial and industrial low-voltage installations.
Featuring a thermal-magnetic trip arrangement, designated TMA in the Protecta Power product description, the EPX-A1C-040L2 combines thermal overload protection with magnetic short-circuit protection. The ABB Protecta Power A1N125 single-pole range specifies a 25 kA breaking capacity, making this device suitable for appropriately designed distribution systems where the prospective fault current does not exceed the applicable circuit breaker rating.
With a 40 A rated current, single-pole construction and L2 load side connector (LSC), the EPX-A1C-040L2 supports integration into compatible Protecta Power outgoing circuit arrangements. Its 125 A A1N125 frame family provides a compact protective solution for individual circuits requiring the designated L2 connection configuration.
The ABB EPX-A1C-040L2 protects outgoing electrical circuits against excessive current caused by overloads and short-circuit faults. Thermal protection responds to sustained overcurrent conditions, while magnetic protection provides rapid disconnection during high fault current events. Together, these functions help reduce the risk of damage to electrical cables, connected equipment and distribution infrastructure.
The ABB Formula A1N125 platform provides a compact circuit protection solution for compatible Protecta Power panelboards. The EPX-A1C-040L2 combines a 40 A protective rating with an L2 load side connector for the designated outgoing connection arrangement. Electrical designers should verify the prospective short-circuit current, operating voltage, conductor sizing, terminal compatibility and distribution assembly requirements before installation.
| Product series | Protecta Power / Formula A1N125 |
|---|---|
| ABB order code | 1SDA123200R1 |
| Product type | Moulded case circuit breaker with load side connector |
| Rated current | 40 A |
| Number of poles | 1 |
| Circuit breaker family | A1N125 |
| Frame current class | 125 A |
| Breaking capacity | 25 kA, subject to the applicable operating voltage and installation conditions |
| Trip technology | Thermal-magnetic |
| Manufacturer trip designation | TMA |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Connector designation | LSC |
| Phase designation | L2 |
| Maximum cable capacity for A1 single-pole devices | 50 mm², subject to terminal suitability |
| Connection arrangement | Single-pole with L2 load side connector |
| Installation | Compatible ABB Protecta Power outgoing circuit assembly |
| Product group | Protecta Power Devices |
| Application | Low-voltage outgoing circuit protection |
The ABB EPX-A1C-040L2 is a 40 A single-pole thermal-magnetic moulded case circuit breaker with an L2 load side connector, designed for outgoing circuit protection in compatible ABB Protecta Power electrical distribution assemblies.
The EPX-A1C-040L2 has a 40 A rated current and belongs to the ABB Formula A1N125 circuit breaker family, which has a 125 A frame class. The frame designation does not change the device's 40 A protective rating.
The ABB Protecta Power A1N125 single-pole range specifies a 25 kA breaking capacity. The applicable breaking capacity must be verified against the operating voltage and prospective short-circuit current of the installation.
TMA identifies the thermal-magnetic trip arrangement, LSC identifies the load side connector and L2 specifies the designated phase connection. These designations describe the protection and connection configuration of the EPX-A1C-040L2.
Both devices are 40 A single-pole ABB A1N125 thermal-magnetic MCCBs intended for compatible Protecta Power distribution assemblies. The difference is the designated load side connector position: EPX-A1C-040L2 is configured for L2, while EPX-A1C-040L1 is configured for L1. The correct version should be selected for the panelboard connection arrangement.
ABB Formula circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with dependable solutions for low-voltage circuit protection. The EPX-A1C-040L2 combines a 40 A single-pole protective rating, A1N125 thermal-magnetic technology and an L2 load side connector to support reliable outgoing circuit protection within compatible commercial and industrial distribution assemblies.