Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-A1C-032L2 is a 32 A single-pole A1N125 moulded case circuit breaker assembly with TMA thermal-magnetic protection, 25 kA breaking capacity and an LSC L2 connection arrangement for compatible Protecta Power distribution systems.
£194.77
The ABB EPX-A1C-032L2 is a reliable 32 A single-pole moulded case circuit breaker (MCCB) designed for electrical circuit protection in commercial and industrial power distribution systems. As part of the ABB Protecta Power distribution range, this device combines an A1N125 circuit breaker with an L2 load-side connection (LSC) and thermal-magnetic protection for dependable operation in low-voltage electrical installations.
The EPX-A1C-032L2 provides protection against overloads and short circuits, helping safeguard electrical cables, connected equipment and distribution infrastructure. Its TMA thermal-magnetic trip arrangement provides protective functionality suitable for outgoing distribution circuits, while the integrated L2 connection configuration supports installation within compatible ABB Protecta Power distribution assemblies.
With a 32 A rated current, single-pole configuration and 25 kA breaking capacity for the specified A1N125 Protecta Power application, the EPX-A1C-032L2 is suitable for commercial distribution boards, electrical switchboards and industrial power distribution installations requiring reliable circuit isolation and fault protection.
The ABB EPX-A1C-032L2 provides dependable electrical protection through its thermal-magnetic circuit breaker arrangement. Thermal protection responds to sustained overload conditions, while magnetic protection provides rapid disconnection during high-current short-circuit faults. These complementary protection functions help minimise the risk of damage to electrical cables and connected equipment.
The ABB A1N125 platform is designed for low-voltage circuit protection, while the Protecta Power L2 configuration enables integration into compatible distribution board assemblies. The single-pole design makes the EPX-A1C-032L2 suitable for protecting individual outgoing phase circuits in commercial and industrial electrical distribution systems.
The ABB Protecta Power system supports structured distribution board construction using compatible circuit breakers, connection arrangements and mounting accessories. Appropriate coordination with upstream protection and correct installation are essential for achieving the required electrical protection performance.
| Product range | Protecta Power Devices |
|---|---|
| ABB order code | 1SDA123199R1 |
| Product type | Moulded case circuit breaker (MCCB) assembly |
| Circuit breaker series | ABB Formula A1 |
| Circuit breaker designation | A1N125 |
| Rated current | 32 A |
| Frame rating | 125 A |
| Number of poles | 1P (single pole) |
| Breaking capacity | 25 kA (specified Protecta Power application) |
| Trip unit | TMA thermal-magnetic |
| Thermal protection | Overload protection |
| Magnetic protection | Short-circuit protection |
| Connection configuration | LSC L2 |
| Phase arrangement | L2 |
| Installation | Compatible ABB Protecta Power distribution assemblies |
| Application | Low-voltage outgoing circuit protection |
| Product category | Protecta Power Devices |
The ABB EPX-A1C-032L2 is a 32 A single-pole moulded case circuit breaker assembly designed to protect outgoing electrical circuits against overloads and short circuits in compatible ABB Protecta Power distribution systems.
The EPX-A1C-032L2 has a 32 A rated current and uses the ABB A1N125 circuit breaker platform with a 125 A frame rating.
The EPX-A1C-032L2 is specified with a 25 kA breaking capacity for the ABB Protecta Power application. The applicable voltage and installation conditions must be considered when verifying short-circuit protection requirements.
TMA refers to the thermal-magnetic trip arrangement, which provides thermal protection against sustained overloads and magnetic protection against short-circuit faults.
The L2 designation identifies the phase-specific connection arrangement used for integration into compatible ABB Protecta Power distribution assemblies.
Yes. The EPX-A1C-032L2 belongs to the ABB Protecta Power Devices range and is intended for compatible distribution board assemblies. The appropriate MCCB mounting base plate, cover and installation accessories must be selected for the application.
ABB Protecta Power circuit protection devices provide dependable overload and short-circuit protection for commercial and industrial electrical distribution installations. The EPX-A1C-032L2 combines a 32 A A1N125 single-pole circuit breaker with an L2 connection arrangement and thermal-magnetic protection for integration into compatible Protecta Power assemblies.