1SDA123196R1 ABB EPX-A1C-020L2 Protecta Power 20A 1-Pole A1N125 Thermal Magnetic MCCB with LSC L2

1SDA123196R1 ABB EPX-A1C-020L2 Protecta Power 20A 1-Pole A1N125 Thermal Magnetic MCCB with LSC L2

ABB EPX-A1C-020L2 (1SDA123196R1) 20 A single-pole Formula A1N125 thermal-magnetic outgoing MCCB with LSC L2 connection arrangement and 25 kA published breaking-capacity classification for compatible ABB Protecta Power distribution panelboards.

SKU: 1SDA123196R1Alt SKU: EPX-A1C-020L2MPN: 1SDA123196R1
Price
List Price £194.77 ex VAT
Your Price (ex VAT)
£194.77
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.77

Why Choose the ABB EPX-A1C-020L2 20A Single-Pole Thermal-Magnetic MCCB?

The ABB EPX-A1C-020L2 is a 20 A single-pole moulded case circuit breaker (MCCB) supplied with an LSC L2 connection arrangement for compatible ABB Protecta Power electrical distribution panelboards. Identified by manufacturer order code 1SDA123196R1, this device belongs to the ABB Protecta Power Devices product group and provides dedicated outgoing circuit protection for professionally designed low-voltage distribution assemblies.

Based on the ABB Formula A1N125 circuit breaker platform, the EPX-A1C-020L2 incorporates thermal-magnetic protection to respond to overload and short-circuit conditions. Its 20 A current rating and single-pole (1P) configuration make it suitable for appropriately specified outgoing circuits requiring reliable overcurrent protection within a compatible Protecta Power panelboard.

ABB identifies the 20 A A1N125 outgoing MCCB with a 25 kA breaking-capacity classification in its Protecta Power selection literature. The product's L2 designation distinguishes its connection arrangement from the corresponding L1 and L3 versions. Together, the Formula A1N125 device, thermal-magnetic protection and LSC L2 arrangement provide a clearly specified solution for contractors, electrical designers and panel builders selecting ABB outgoing protective devices.

Key Advantages

  • Purpose-designed 20 A outgoing MCCB for compatible ABB Protecta Power electrical distribution panelboards.
  • Single-pole (1P) configuration for suitable individual outgoing circuits.
  • Uses the established ABB Formula A1N125 moulded case circuit breaker platform.
  • Provides thermal-magnetic overload and short-circuit protection.
  • Features a 25 kA breaking-capacity classification in ABB Protecta Power selection literature, subject to the applicable voltage and device specification.
  • Supplied in the specified LSC L2 connection variant.
  • Combines manual circuit switching with automatic overcurrent tripping.
  • Supports coordinated outgoing device selection across ABB Protecta Power assemblies.
  • Clearly differentiated from the corresponding L1 and L3 connection variants.
  • Suitable for commercial, industrial and institutional low-voltage distribution applications.
  • Supports professional panelboard construction, replacement and refurbishment projects.
  • Genuine ABB product identified by manufacturer order code 1SDA123196R1.

Key Features

  • ABB Protecta Power Devices product group.
  • EPX-A1C-020L2 manufacturer product reference.
  • 20 A rated current.
  • Single-pole (1P) configuration.
  • ABB Formula A1N125 circuit breaker family.
  • 125 A frame family with a 20 A device rating.
  • Thermal-magnetic (TMA) protection designation.
  • Thermal overload protection function.
  • Magnetic short-circuit protection function.
  • 25 kA published outgoing MCCB breaking-capacity classification.
  • LSC L2 connection arrangement.
  • Designed for compatible ABB Protecta Power outgoing circuit positions.
  • Corresponding L1 and L3 variants available for alternative connection arrangements.
  • Manual switching and automatic protective tripping.
  • Requires compatible outgoing MCCB mounting and cover components within the completed panelboard assembly.
  • ABB order code 1SDA123196R1.

Reliable 20A Outgoing Circuit Protection with ABB Formula A1N125 Technology

Outgoing circuit protection is an essential part of a professionally designed electrical distribution panelboard. Each outgoing protective device must be selected according to the intended load, conductor characteristics, installation conditions and prospective fault current. The ABB EPX-A1C-020L2 provides a 20 A single-pole MCCB solution for compatible Protecta Power assemblies, helping protect the connected circuit against overload and short-circuit conditions.

The product uses the ABB Formula A1N125 platform, a moulded case circuit breaker family designed for low-voltage electrical protection applications. The A1N125 designation identifies the circuit breaker family and frame classification, while the 20 A rating identifies the current rating of this particular device. The 125 A frame designation should not be confused with the protective device's specified 20 A rating.

The thermal-magnetic protection arrangement combines two complementary overcurrent protection functions. The thermal element responds to sustained overload conditions that can cause excessive heating in electrical conductors and equipment. The magnetic element responds to sufficiently high short-circuit currents, providing rapid protective tripping when the applicable operating threshold is reached.

ABB's Protecta Power selection literature identifies the 20 A single-pole A1N125 outgoing MCCB with a 25 kA breaking-capacity classification. This distinguishes it from the 16 A A1C125 outgoing device, which ABB lists with an 18 kA classification. The relevant breaking capacity must always be verified at the installation's operating voltage and against the exact circuit breaker documentation before specification.

The LSC L2 designation is an important part of the product reference. ABB provides three corresponding 20 A connection variants: EPX-A1C-020L1, EPX-A1C-020L2 and EPX-A1C-020L3. These references allow the correct connection arrangement to be selected for the designated outgoing position. The variants should not be substituted without checking the panelboard's approved connection configuration.

ABB's Protecta Power outgoing MCCB system uses coordinated mounting and cover components to integrate protective devices into the finished assembly. The manufacturer's selection literature states that an MCCB base plate and cover are required with each outgoing device. Consequently, the EPX-A1C-020L2 should be treated as an outgoing protective device for installation within a compatible distribution assembly, rather than a complete enclosed circuit protection solution.

The manufacturer's published Protecta Power information identifies a maximum cable capacity of 50 mm² for A1 single-pole devices. This figure describes the connection capability of the relevant device arrangement and is not a recommended conductor size for a 20 A circuit. The actual cable cross-section must be selected according to the electrical load, installation method, voltage drop, fault protection requirements and terminal compatibility.

When specifying the EPX-A1C-020L2, the electrical designer must verify the rated operational voltage, short-circuit breaking capacity, protective characteristics, conductor compatibility and panelboard installation requirements. Appropriate coordination with upstream and downstream protective devices should also be considered. Installation and commissioning must follow current ABB technical documentation and applicable electrical installation requirements.

Typical Applications

  • ABB Protecta Power outgoing electrical distribution circuits.
  • 20 A single-pole MCCB protection within compatible panelboards.
  • Protecta Power assemblies requiring the LSC L2 connection arrangement.
  • Commercial building low-voltage distribution systems.
  • Industrial electrical distribution panelboards.
  • Individual outgoing circuits requiring appropriately specified overcurrent protection.
  • Office and retail electrical installations.
  • Warehouses and logistics facilities.
  • Manufacturing and light industrial premises.
  • Educational and institutional building distribution systems.
  • Electrical switchrooms and sub-distribution assemblies.
  • Professional electrical panel building and switchgear manufacturing.
  • Compatible outgoing MCCB replacement applications.
  • Protecta Power panelboard refurbishment and expansion projects.

Technical Specifications

Product group Protecta Power Devices
Compatible distribution range ABB Protecta Power
ABB order code 1SDA123196R1
Manufacturer product description A1N125 20A 1p + LSC L2 TMA
Product type Moulded case circuit breaker (MCCB) with LSC connection arrangement
Device application Outgoing circuit protection
Rated current 20 A
Number of poles 1P (single-pole)
Circuit breaker family ABB Formula A1N125
Frame family 125 A
Protection technology Thermal-magnetic
Trip designation TMA
Overload protection Thermal trip function
Short-circuit protection Magnetic trip function
Published breaking-capacity classification 25 kA; verify the applicable operational voltage and detailed ABB ratings
Connection arrangement LSC L2
Connection variant L2
Alternative connection variants EPX-A1C-020L1 and EPX-A1C-020L3
Published A1 single-pole maximum cable capacity 50 mm², subject to terminal and installation requirements
Associated mounting components Compatible outgoing MCCB base plate and cover
Operating functionality Manual switching and automatic overcurrent tripping
System type Low-voltage electrical distribution
Application Compatible ABB Protecta Power outgoing circuits

Frequently Asked Questions

What is the ABB EPX-A1C-020L2 used for?

The ABB EPX-A1C-020L2 is a 20 A single-pole thermal-magnetic MCCB with an LSC L2 connection arrangement. It is designed for compatible ABB Protecta Power outgoing distribution circuits and provides overload and short-circuit protection.

What does L2 mean in the ABB EPX-A1C-020L2 product code?

L2 identifies the specified connection variant within ABB's Protecta Power single-pole outgoing MCCB range. ABB also lists EPX-A1C-020L1 and EPX-A1C-020L3 versions. The correct variant should be selected according to the approved panelboard connection arrangement.

What is the current rating and pole configuration of the EPX-A1C-020L2?

The EPX-A1C-020L2 has a 20 A current rating and a single-pole (1P) configuration. It belongs to the ABB Formula A1N125 circuit breaker family. The 125 A frame designation does not change the device's specified 20 A rating.

What is the breaking capacity of the ABB EPX-A1C-020L2?

ABB's Protecta Power selection literature identifies the 20 A single-pole A1N125 outgoing MCCB with a 25 kA breaking-capacity classification. The applicable rated operational voltage and detailed breaking-capacity specification must be verified against the manufacturer's technical documentation before installation.

Does the ABB EPX-A1C-020L2 require a separate base plate and cover?

Yes. ABB's Protecta Power selection literature specifies that an MCCB base plate and cover are required with each outgoing device. The correct accessories must be selected for the panelboard and circuit breaker arrangement. The EPX-A1C-020L2 is not a complete enclosed distribution assembly on its own.

Trusted by Electrical Contractors and Panel Builders Worldwide

ABB Protecta Power provides coordinated low-voltage electrical distribution components for commercial and industrial installations. The EPX-A1C-020L2 combines a 20 A single-pole Formula A1N125 circuit breaker with thermal-magnetic protection, a published 25 kA breaking-capacity classification and an LSC L2 connection arrangement, giving electrical contractors and panel builders a clearly identified outgoing protection option for compatible Protecta Power assemblies.