1SDA123188R1 ABB EPX-A1C-100L1 A1N125 100A 1p+ LSC L1 TMA Circuit Breaker Protecta Power

1SDA123188R1 ABB EPX-A1C-100L1 A1N125 100A 1p+ LSC L1 TMA Circuit Breaker Protecta Power

ABB EPX-A1C-100L1 (1SDA123188R1) is a 100 A A1N125 protective circuit breaker with a manufacturer-designated 1p+ LSC L1 configuration and thermal-magnetic adjustable (TMA) protection, part of the ABB Protecta Power Devices range.

SKU: 1SDA123188R1Alt SKU: EPX-A1C-100L1MPN: 1SDA123188R1
Price
List Price £204.11 ex VAT
Your Price (ex VAT)
£204.11
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £204.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£204.11

Why Choose the ABB EPX-A1C-100L1 100A A1N125 Circuit Breaker?

The ABB EPX-A1C-100L1, manufacturer order code 1SDA123188R1, is a 100 A single-pole circuit breaker with LSC L1 configuration and thermal-magnetic adjustable (TMA) protection. Part of the ABB Protecta Power Devices product group, it is designed for compatible low-voltage electrical distribution arrangements requiring dependable circuit protection and switching.

Officially described as the EPX-A1C-100L1 A1N125 100A 1p+ LSC L1 TMA, this device combines a 100 A current rating with the ABB A1N125 circuit breaker platform. Its L1 designation identifies the phase-specific configuration, while the LSC designation forms part of ABB's manufacturer-defined product description.

The thermal-magnetic adjustable protection provides overload and short-circuit protection using thermal and magnetic tripping principles. This makes the EPX-A1C-100L1 suitable for professionally designed electrical distribution systems where a 100 A protective device is required and the installation has been verified against the manufacturer's operating characteristics.

For electrical contractors, switchgear manufacturers and panel builders, the ABB EPX-A1C-100L1 offers a clearly identified protective device within the Protecta Power range. Its combination of A1N125 construction, 100 A rating and L1 configuration helps support accurate device selection for compatible distribution assemblies.

Key Advantages

  • 100 A rated circuit breaker for suitable low-voltage distribution circuits.
  • ABB A1N125 platform for the designated protective device arrangement.
  • Single-pole designation with manufacturer-specified 1p+ configuration.
  • Thermal-magnetic adjustable (TMA) protection for overload and short-circuit conditions.
  • LSC L1 configuration for the specified phase arrangement.
  • Part of the ABB Protecta Power Devices product group.
  • Supports professional circuit protection and distribution equipment design.
  • Provides automatic protective tripping as well as manual switching capability.
  • Available alongside other current ratings and phase-specific variants in the same ABB product family.
  • Dedicated ABB order code 1SDA123188R1 supports accurate procurement and product identification.

Key Features

  • ABB EPX-A1C-100L1 protective circuit breaker.
  • 100 A rated current.
  • ABB A1N125 device designation.
  • 1p+ configuration as stated by ABB.
  • LSC manufacturer configuration designation.
  • L1 phase designation.
  • TMA thermal-magnetic adjustable trip technology.
  • Thermal overload protection.
  • Magnetic short-circuit protection.
  • Automatic tripping under qualifying fault conditions.
  • Manual circuit switching capability.
  • Designed for compatible low-voltage electrical distribution assemblies.
  • Part of the ABB Protecta Power protective device range.
  • Manufacturer-listed alternatives for L2 and L3 phase configurations.
  • Suitable for installation by qualified electrical professionals.
  • ABB manufacturer order code 1SDA123188R1.

Specification note: The exact breaking capacity, operational voltage, trip adjustment range, terminal configuration, dimensions and mechanical installation requirements should be confirmed against ABB's technical documentation for 1SDA123188R1. The manufacturer's 1p+ and LSC designations should be interpreted using the relevant ABB product documentation rather than assuming that they identify a conventional single-pole MCB arrangement.

ABB A1N125 Thermal-Magnetic Circuit Protection

The ABB EPX-A1C-100L1 belongs to a family of Protecta Power devices based on the A1N125 platform. The manufacturer identifies this particular variant as a 100 A 1p+ LSC L1 TMA device, providing a specific combination of current rating, phase designation and protective technology.

The thermal-magnetic adjustable (TMA) protection system uses two complementary operating principles. The thermal element responds to sustained overload conditions, while the magnetic element responds to short-circuit currents. Together, these functions provide automatic protective tripping within the device's specified operating limits.

Thermal overload protection is intended to reduce the risk of excessive conductor and equipment heating caused by prolonged overcurrent. The appropriate device rating and trip settings must be selected according to the protected circuit's design current, conductor capacity and installation conditions.

Magnetic short-circuit protection responds to qualifying fault currents. The selected circuit breaker must have a suitable rated breaking capacity for the prospective short-circuit current at its installation point. A 100 A rated current must not be confused with the device's short-circuit breaking capacity.

The A1N125 designation identifies the manufacturer's device platform, while the 100 A rating identifies this particular product variant. Other devices within the same platform may have different rated currents and phase-specific configurations.

As with other protective circuit breakers, the EPX-A1C-100L1 must be selected with consideration of the complete electrical installation. This includes conductor sizing, protective coordination, installation environment, fault current and compatibility with the intended distribution assembly.

Understanding the LSC L1 Configuration

One of the distinguishing features of the ABB EPX-A1C-100L1 is its manufacturer-defined LSC L1 configuration. ABB uses this designation to identify the particular variant within its Protecta Power device range.

The L1 designation identifies this product as the L1 version. ABB also lists corresponding L2 and L3 versions within the same product family, allowing the correct manufacturer-designated device to be selected for the intended phase arrangement.

The related EPX-A1C-100L2 and EPX-A1C-100L3 models share the same nominal 100 A rating and A1N125 platform designation, but are separately identified products. Their individual ABB order codes and phase designations should be checked before procurement.

The 1p+ designation should also be preserved when specifying the device. It forms part of ABB's official product description and should not be simplified to an assumed pole arrangement without reference to the manufacturer's technical drawings.

Correct phase-specific selection is important when installing protective devices into a distribution assembly. The electrical contractor or panel builder should verify the required device orientation, phase connection, mounting arrangement and associated accessories against ABB's installation documentation.

Part of the ABB Protecta Power Protective Device Range

The ABB Protecta Power product family includes protective devices and distribution equipment for commercial and industrial low-voltage installations. The EPX-A1C-100L1 is listed under the Protecta Power Devices product group rather than the enclosure-only category.

ABB's A1N125 LSC L1 range includes several current ratings, allowing designers to select a device appropriate to the intended circuit. The manufacturer lists L1 variants including 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A and 125 A.

For applications requiring a lower-rated protective device, the EPX-A1C-080L1 provides an 80 A alternative within the same designated range. For circuits requiring a 125 A device, ABB lists the EPX-A1C-125L1.

The correct current rating must be determined through the electrical design rather than selecting the highest available rating. Protective device selection must account for conductor current-carrying capacity, load characteristics, prospective fault current and the required protective performance.

The EPX-A1C-100L1 is a protective device, not a complete electrical distribution panelboard. Any compatible enclosure, mounting components, connection accessories or additional protective equipment must be selected separately unless their inclusion is expressly confirmed by the supplier.

When replacing an existing device, the model designation and ABB order code should be checked carefully. A device with a similar current rating may not have the same phase designation, connection arrangement or approved installation characteristics.

Typical Applications

  • Compatible ABB Protecta Power electrical distribution assemblies.
  • 100 A L1-designated circuit protection.
  • Commercial building low-voltage electrical distribution.
  • Industrial distribution panelboard installations.
  • Electrical circuits requiring thermal-magnetic protection.
  • Professional switchgear manufacturing and panel building.
  • Electrical plant rooms and distribution equipment installations.
  • Office buildings and commercial developments.
  • Retail centres and mixed-use properties.
  • Warehouses and logistics facilities.
  • Manufacturing and industrial premises.
  • Infrastructure and institutional electrical installations.
  • Compatible ABB Protecta Power protective device replacement projects.

Technical Specifications

Product group Protecta Power Devices
Product series ABB Protecta Power
ABB order code 1SDA123188R1
Manufacturer description EPX-A1C-100L1 A1N125 100A 1p+ LSC L1 TMA
Product type Protective circuit breaker
Device designation A1N125
Rated current 100 A
Pole designation 1p+
Manufacturer configuration LSC
Phase designation L1
Trip technology Thermal-magnetic adjustable (TMA)
Overload protection Thermal trip function
Short-circuit protection Magnetic trip function
Primary functions Circuit protection and switching
Compatible product family ABB Protecta Power
Alternative 100 A L2 variant EPX-A1C-100L2
Alternative 100 A L3 variant EPX-A1C-100L3
Lower-rated L1 variant EPX-A1C-080L1, 80 A
Higher-rated L1 variant EPX-A1C-125L1, 125 A
Application Low-voltage electrical distribution circuit protection
Installation requirement Selection and installation in accordance with ABB documentation and applicable electrical standards

Frequently Asked Questions

What is the ABB EPX-A1C-100L1 used for?

The ABB EPX-A1C-100L1 is a 100 A A1N125 protective circuit breaker with a manufacturer-designated 1p+ LSC L1 TMA configuration. It is intended for compatible low-voltage distribution assemblies requiring thermal-magnetic overload and short-circuit protection.

What does TMA mean on the ABB EPX-A1C-100L1?

TMA stands for thermal-magnetic adjustable. This protection technology uses a thermal element for overload protection and a magnetic element for short-circuit protection. The applicable adjustment characteristics must be confirmed against ABB's device documentation.

What is the difference between ABB EPX-A1C-100L1, EPX-A1C-100L2 and EPX-A1C-100L3?

These are separately identified 100 A A1N125 TMA devices with different manufacturer phase designations. The EPX-A1C-100L1 is the L1 variant, the EPX-A1C-100L2 is the L2 variant and the EPX-A1C-100L3 is the L3 variant. The correct version must be selected for the intended assembly arrangement.

Is the ABB EPX-A1C-100L1 a 100A or 125A circuit breaker?

The EPX-A1C-100L1 is rated at 100 A. The A1N125 designation identifies the device platform. ABB also lists a separate EPX-A1C-125L1 variant with a 125 A rating.

Does the ABB EPX-A1C-100L1 include a complete Protecta Power panelboard?

No. The EPX-A1C-100L1 is a protective circuit breaker within the ABB Protecta Power Devices range. It is not a complete electrical distribution panelboard. The compatible enclosure, mounting arrangement and any required connection accessories must be confirmed separately.

ABB Thermal-Magnetic Circuit Protection for Professional Panel Builders

The ABB EPX-A1C-100L1 100 A A1N125 Circuit Breaker, order code 1SDA123188R1, combines a manufacturer-designated LSC L1 configuration with thermal-magnetic adjustable protection. As part of the ABB Protecta Power Devices range, it provides a clearly specified protective device for compatible low-voltage distribution assemblies where correct current rating, phase configuration and circuit protection are essential.