ABB EPX-A1C-025L1 Protecta Power 25 A single-pole A1N125 thermal-magnetic adjustable moulded case circuit breaker with L1 load side connector for outgoing circuit protection in compatible low-voltage electrical distribution assemblies.
£194.77
The ABB EPX-A1C-025L1 is a compact 25 A single-pole moulded case circuit breaker (MCCB) with an L1 load side connector, designed for reliable circuit protection in commercial and industrial low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, this protective device incorporates ABB A1N125 circuit breaker technology and thermal-magnetic protection to safeguard electrical circuits against overloads and short-circuit faults.
Featuring a thermal-magnetic adjustable (TMA) trip unit, the EPX-A1C-025L1 provides conventional overcurrent protection without requiring an electronic trip system. Its thermal protection responds to sustained overload conditions, while magnetic tripping provides protection against short-circuit faults. The compact A1N125 platform is suitable for applications requiring dependable single-pole circuit protection within compatible electrical distribution assemblies.
With a 25 A rated current, single-pole configuration and L1 load side connector (LSC), the EPX-A1C-025L1 is intended for compatible ABB Protecta Power outgoing circuit arrangements. The dedicated L1 configuration supports the correct connection of the protective device within the designated distribution system, making it a practical choice for panel builders and electrical contractors.
Thermal-magnetic moulded case circuit breakers such as the ABB EPX-A1C-025L1 protect electrical distribution circuits against sustained overloads and short-circuit faults. The thermal trip mechanism responds to excessive current over time, while the magnetic trip mechanism provides rapid operation under sufficiently high fault current conditions. These complementary protection functions help reduce the risk of damage to cables, connected equipment and electrical distribution infrastructure.
The ABB A1N125 circuit breaker platform provides a compact solution for individual outgoing circuit protection. The EPX-A1C-025L1 combines a 25 A TMA protective device with an L1 load side connector for compatible Protecta Power arrangements. Correct installation requires the circuit breaker rating, fault-breaking capacity, conductor connections and distribution assembly compatibility to be verified against the electrical design and applicable ABB technical documentation.
| Series | Protecta Power / A1N125 |
|---|---|
| ABB order code | 1SDA123178R1 |
| Product type | Thermal-magnetic moulded case circuit breaker (MCCB) with load side connector |
| Rated current | 25 A |
| Number of poles | 1 |
| Circuit breaker family | A1N125 |
| Frame current class | 125 A |
| Trip unit technology | Thermal-magnetic |
| Trip unit designation | TMA |
| Overload protection | Thermal |
| Short-circuit protection | Magnetic |
| Connector designation | LSC |
| Phase designation | L1 |
| Connection arrangement | Single-pole with load side connector |
| Installation type | Compatible electrical distribution assembly mounting |
| Product group | Protecta Power Devices |
| Application | Low-voltage outgoing circuit protection |
The ABB EPX-A1C-025L1 is a 25 A single-pole thermal-magnetic moulded case circuit breaker with an L1 load side connector, designed for outgoing circuit protection in compatible ABB Protecta Power electrical distribution assemblies.
The EPX-A1C-025L1 has a 25 A rated current and belongs to the ABB A1N125 circuit breaker family, which uses a 125 A frame class. The 25 A rating identifies the protective device, rather than the maximum current capacity of the frame family.
TMA means thermal-magnetic adjustable. This trip technology combines thermal overload protection with magnetic short-circuit protection, providing conventional overcurrent protection for electrical distribution circuits.
L1 identifies the designated phase connection, while LSC refers to the load side connector. The EPX-A1C-025L1 is supplied in an L1 connector configuration intended for compatible ABB Protecta Power distribution arrangements.
The EPX-A1C-025L1 belongs to the ABB Protecta Power Devices range and incorporates ABB A1N125 MCCB technology. Its ABB manufacturer order code is 1SDA123178R1.
ABB moulded case circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with dependable solutions for low-voltage electrical protection. The EPX-A1C-025L1 combines 25 A single-pole protection, A1N125 thermal-magnetic circuit breaker technology and an L1 load side connector to support reliable outgoing circuit protection within compatible commercial and industrial distribution assemblies.