1SDA123178R1 ABB EPX-A1C-025L1 Protecta Power A1N125 25A 1-Pole TMA MCCB with L1 Load Side Connector

1SDA123178R1 ABB EPX-A1C-025L1 Protecta Power A1N125 25A 1-Pole TMA MCCB with L1 Load Side Connector

ABB EPX-A1C-025L1 Protecta Power 25 A single-pole A1N125 thermal-magnetic adjustable moulded case circuit breaker with L1 load side connector for outgoing circuit protection in compatible low-voltage electrical distribution assemblies.

SKU: 1SDA123178R1Alt SKU: EPX-A1C-025L1MPN: 1SDA123178R1
Price
List Price £194.77 ex VAT
Your Price (ex VAT)
£194.77
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.77

Why Choose the ABB EPX-A1C-025L1 25A Single-Pole MCCB with L1 Load Side Connector?

The ABB EPX-A1C-025L1 is a compact 25 A single-pole moulded case circuit breaker (MCCB) with an L1 load side connector, designed for reliable circuit protection in commercial and industrial low-voltage electrical distribution systems. As part of the ABB Protecta Power Devices range, this protective device incorporates ABB A1N125 circuit breaker technology and thermal-magnetic protection to safeguard electrical circuits against overloads and short-circuit faults.

Featuring a thermal-magnetic adjustable (TMA) trip unit, the EPX-A1C-025L1 provides conventional overcurrent protection without requiring an electronic trip system. Its thermal protection responds to sustained overload conditions, while magnetic tripping provides protection against short-circuit faults. The compact A1N125 platform is suitable for applications requiring dependable single-pole circuit protection within compatible electrical distribution assemblies.

With a 25 A rated current, single-pole configuration and L1 load side connector (LSC), the EPX-A1C-025L1 is intended for compatible ABB Protecta Power outgoing circuit arrangements. The dedicated L1 configuration supports the correct connection of the protective device within the designated distribution system, making it a practical choice for panel builders and electrical contractors.

Key Advantages

  • 25 A moulded case circuit breaker designed for reliable low-voltage circuit protection.
  • Single-pole configuration suitable for individual outgoing electrical circuits.
  • ABB A1N125 circuit breaker platform provides compact and dependable protection.
  • Thermal-magnetic adjustable (TMA) trip unit provides overload and short-circuit protection.
  • Integrated L1 load side connector supports connection within compatible distribution arrangements.
  • Designed for integration into ABB Protecta Power electrical distribution assemblies.
  • Supports organised circuit protection and practical panelboard configuration.

Key Features

  • ABB Protecta Power Devices range.
  • 25 A rated current.
  • Single-pole (1P) circuit breaker configuration.
  • ABB A1N125 moulded case circuit breaker platform.
  • 125 A A1N125 frame family.
  • Thermal-magnetic adjustable (TMA) trip technology.
  • Thermal protection against sustained overload conditions.
  • Magnetic protection against short-circuit fault currents.
  • Load side connector (LSC) configuration.
  • L1 phase connection designation.
  • Manual switching and circuit breaker reset functionality.
  • Designed for outgoing circuit protection within compatible ABB Protecta Power distribution equipment.
  • ABB manufacturer order code 1SDA123178R1.

Reliable Circuit Protection for Low-Voltage Electrical Distribution

Thermal-magnetic moulded case circuit breakers such as the ABB EPX-A1C-025L1 protect electrical distribution circuits against sustained overloads and short-circuit faults. The thermal trip mechanism responds to excessive current over time, while the magnetic trip mechanism provides rapid operation under sufficiently high fault current conditions. These complementary protection functions help reduce the risk of damage to cables, connected equipment and electrical distribution infrastructure.

The ABB A1N125 circuit breaker platform provides a compact solution for individual outgoing circuit protection. The EPX-A1C-025L1 combines a 25 A TMA protective device with an L1 load side connector for compatible Protecta Power arrangements. Correct installation requires the circuit breaker rating, fault-breaking capacity, conductor connections and distribution assembly compatibility to be verified against the electrical design and applicable ABB technical documentation.

Typical Applications

  • ABB Protecta Power electrical distribution assemblies.
  • Commercial building outgoing circuit protection.
  • Industrial low-voltage electrical distribution systems.
  • Single-phase circuits supplied from compatible three-phase distribution boards.
  • Electrical plant rooms and building services installations.
  • Manufacturing facilities and industrial control infrastructure.
  • Warehouses, workshops and commercial premises.
  • Panel building projects requiring 25 A single-pole MCCB protection with an L1 load side connector.

Technical Specifications

Series Protecta Power / A1N125
ABB order code 1SDA123178R1
Product type Thermal-magnetic moulded case circuit breaker (MCCB) with load side connector
Rated current 25 A
Number of poles 1
Circuit breaker family A1N125
Frame current class 125 A
Trip unit technology Thermal-magnetic
Trip unit designation TMA
Overload protection Thermal
Short-circuit protection Magnetic
Connector designation LSC
Phase designation L1
Connection arrangement Single-pole with load side connector
Installation type Compatible electrical distribution assembly mounting
Product group Protecta Power Devices
Application Low-voltage outgoing circuit protection

Frequently Asked Questions

What is the ABB EPX-A1C-025L1 used for?

The ABB EPX-A1C-025L1 is a 25 A single-pole thermal-magnetic moulded case circuit breaker with an L1 load side connector, designed for outgoing circuit protection in compatible ABB Protecta Power electrical distribution assemblies.

What is the current rating of the EPX-A1C-025L1?

The EPX-A1C-025L1 has a 25 A rated current and belongs to the ABB A1N125 circuit breaker family, which uses a 125 A frame class. The 25 A rating identifies the protective device, rather than the maximum current capacity of the frame family.

What does TMA mean on the EPX-A1C-025L1?

TMA means thermal-magnetic adjustable. This trip technology combines thermal overload protection with magnetic short-circuit protection, providing conventional overcurrent protection for electrical distribution circuits.

What does L1 and LSC mean in the product description?

L1 identifies the designated phase connection, while LSC refers to the load side connector. The EPX-A1C-025L1 is supplied in an L1 connector configuration intended for compatible ABB Protecta Power distribution arrangements.

Which ABB product range does the EPX-A1C-025L1 belong to?

The EPX-A1C-025L1 belongs to the ABB Protecta Power Devices range and incorporates ABB A1N125 MCCB technology. Its ABB manufacturer order code is 1SDA123178R1.

Trusted by Electrical Contractors and Panel Builders

ABB moulded case circuit breakers and Protecta Power distribution equipment provide electrical engineers, contractors and panel builders with dependable solutions for low-voltage electrical protection. The EPX-A1C-025L1 combines 25 A single-pole protection, A1N125 thermal-magnetic circuit breaker technology and an L1 load side connector to support reliable outgoing circuit protection within compatible commercial and industrial distribution assemblies.