ABB EPX-A1C-020L1 Protecta Power 20 A single-pole Formula A1N125 thermal-magnetic outgoing MCCB assembly, order code 1SDA123177R1, with a 25 kA breaking capacity listed in ABB’s Protecta Power selection guide and an L1-position load-side connection arrangement for compatible electrical distribution panelboards.
£194.77
The ABB EPX-A1C-020L1 is a 20 A single-pole moulded case circuit breaker (MCCB) assembly designed for outgoing circuit protection in compatible ABB Protecta Power electrical distribution panelboards. Based on the ABB Formula A1N125 circuit breaker platform, it combines thermal-magnetic circuit protection with an L1-position load-side connection (LSC) arrangement for integration into the Protecta Power distribution system.
Part of the ABB Protecta Power Devices product group, the EPX-A1C-020L1 is identified by ABB order code 1SDA123177R1. Its manufacturer product description is EPX-A1C-020L1 A1N125 20A 1p + LSC L1 TMA. The device is intended for applications requiring a manufacturer-specified 20 A outgoing protective device with a single-pole configuration and a dedicated L1 connection arrangement.
ABB's Protecta Power selection information identifies the corresponding 20 A single-pole Formula A1N125 outgoing MCCB as a 25 kA device. The EPX-A1C-020L1 is specifically configured for the L1 connection position, with corresponding L2 and L3 versions available for other phase positions. This supports consistent specification of outgoing circuit protection across compatible Protecta Power assemblies.
The ABB EPX-A1C-020L1 is designed for outgoing electrical circuits requiring a 20 A protective device within a compatible Protecta Power distribution assembly. Its Formula A1N125 platform provides thermal-magnetic protection, combining overload and short-circuit response within a single moulded case circuit breaker.
The thermal element responds to sustained overcurrent conditions that can arise when a circuit is overloaded. The magnetic element responds to higher fault currents associated with short circuits. These protection functions help safeguard the connected electrical installation when the device is correctly selected, installed and coordinated with the circuit conductors and other protective equipment.
ABB's Protecta Power selection information lists the 20 A A1N125 single-pole outgoing MCCB with a 25 kA breaking capacity. This distinguishes it from the related 16 A A1C125 outgoing variant, which ABB lists at 18 kA. The applicable breaking capacity must be checked against the system voltage, prospective short-circuit current and relevant device documentation before installation.
The product description includes the designation TMA. This identifies the thermal-magnetic protection arrangement specified for the Protecta Power assembly. Exact trip characteristics, adjustment facilities and protection settings must be established from the documentation applicable to the supplied circuit breaker. They should not be assumed solely from the general Formula A1 family designation.
Although the circuit breaker belongs to the 125 A A1N125 frame family, the EPX-A1C-020L1 is a 20 A rated outgoing device. The frame designation does not increase the current rating of the protected circuit. Cable selection, load assessment and protective coordination must therefore be based on the actual 20 A device and its documented operating characteristics.
The L1 designation identifies the specified connection position for this outgoing MCCB assembly. ABB also offers the EPX-A1C-020L2 and EPX-A1C-020L3 for corresponding L2 and L3 positions. These references are separate products and should be selected according to the required outgoing way and ABB's panelboard configuration instructions.
The manufacturer's description includes LSC, referring to the associated load-side connection arrangement. This is an important part of the manufacturer-defined outgoing device configuration. The complete installation must provide the correct mechanical mounting, electrical connections, conductor terminations and protective covering for the selected panelboard.
ABB's Protecta Power selection guide specifies that an MCCB base plate and cover are required with each outgoing device. The appropriate components should be selected according to the installed MCCB and panelboard arrangement. Their inclusion in any particular supply package should be checked rather than assumed.
For the A1 single-pole outgoing device range, ABB lists a maximum cable capacity of 50 mm². This is a general selection-guide value, not a recommendation to use a conductor of that size on a 20 A circuit. The actual cable cross-sectional area must be determined from the circuit load, installation method, voltage drop, fault protection requirements and the compatibility of the device terminals.
Related ABB Protecta Power outgoing MCCBs include the EPX-A1B-016L1 rated at 16 A, the EPX-A1C-025L1 rated at 25 A and the EPX-A1C-032L1 rated at 32 A. These devices provide alternative current ratings for different circuit requirements. The appropriate model must be selected from the electrical design rather than substituted solely on the basis of physical compatibility.
| Product group | Protecta Power Devices |
|---|---|
| Series | Protecta Power |
| ABB order code | 1SDA123177R1 |
| Manufacturer product description | EPX-A1C-020L1 A1N125 20A 1p + LSC L1 TMA |
| Product type | Outgoing moulded case circuit breaker assembly |
| Product category | Low-voltage circuit protection devices |
| Device family | ABB Formula A1 |
| Device platform | A1N125 |
| Frame size | 125 A |
| Rated current | 20 A |
| Number of poles | 1 |
| Pole configuration | 1P |
| Breaking capacity listed in ABB Protecta Power selection information | 25 kA |
| Protection technology | Thermal-magnetic |
| Manufacturer trip designation | TMA |
| Protection functions | Overload and short-circuit protection |
| Connection position | L1 |
| Connection arrangement | LSC (load-side connection) |
| Installation position | Outgoing circuit |
| Compatible product family | ABB Protecta Power |
| Maximum cable capacity listed for A1 single-pole outgoing devices | 50 mm², subject to terminal configuration |
| Associated installation accessories | Compatible MCCB base plate and cover |
| Related L2 variant | EPX-A1C-020L2 |
| Related L3 variant | EPX-A1C-020L3 |
| Electrical system | Low-voltage electrical distribution |
| Primary function | Outgoing circuit overload and short-circuit protection |
The ABB EPX-A1C-020L1 is a 20 A single-pole outgoing MCCB assembly designed for compatible ABB Protecta Power electrical distribution panelboards. It provides thermal-magnetic overload and short-circuit protection and is configured for the L1 connection position.
ABB's Protecta Power selection information lists the corresponding 20 A single-pole Formula A1N125 outgoing MCCB with a 25 kA breaking capacity. The relevant system voltage, prospective fault current and device documentation must be checked before specification.
A1N125 identifies the ABB Formula A1 circuit breaker platform and 125 A frame family. L1 identifies the specified connection position, while LSC refers to the associated load-side connection arrangement. The EPX-A1C-020L1 itself is rated at 20 A.
ABB's Protecta Power selection information states that a compatible MCCB base plate and cover are required with each outgoing device. The correct accessories must be selected for the intended panelboard arrangement, and installation must follow the applicable ABB assembly instructions.
The ABB order code is 1SDA123177R1, and the model reference is EPX-A1C-020L1. Its manufacturer product description is EPX-A1C-020L1 A1N125 20A 1p + LSC L1 TMA, within the ABB Protecta Power Devices product group.
ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage protective devices, panelboards and installation accessories. The EPX-A1C-020L1 combines a 20 A single-pole Formula A1N125 thermal-magnetic circuit breaker with an L1-specific load-side connection arrangement, supporting reliable outgoing circuit protection within compatible Protecta Power electrical distribution assemblies.