1SDA123176R1 ABB EPX-A1B-016L1 Protecta Power 16A 1-Pole A1C125 MCCB with L1 Load-Side Connection

1SDA123176R1 ABB EPX-A1B-016L1 Protecta Power 16A 1-Pole A1C125 MCCB with L1 Load-Side Connection

ABB EPX-A1B-016L1 Protecta Power 16 A single-pole Formula A1C125 thermal-magnetic outgoing MCCB assembly, order code 1SDA123176R1, with an L1-position load-side connection arrangement for compatible ABB Protecta Power electrical distribution panelboards.

SKU: 1SDA123176R1Alt SKU: EPX-A1B-016L1MPN: 1SDA123176R1
Price
List Price £194.77 ex VAT
Your Price (ex VAT)
£194.77
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £194.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£194.77

Why Choose the ABB EPX-A1B-016L1 16A Single-Pole MCCB?

The ABB EPX-A1B-016L1 is a 16 A single-pole moulded case circuit breaker (MCCB) assembly designed for outgoing circuit protection within compatible ABB Protecta Power electrical distribution panelboards. Based on the ABB Formula A1C125 circuit breaker platform, this product combines thermal-magnetic protection with an L1-position load-side connection (LSC) arrangement for integration into the Protecta Power distribution system.

Part of the ABB Protecta Power Devices product group, the EPX-A1B-016L1 is identified by ABB order code 1SDA123176R1. Its manufacturer product description is EPX-A1B-016L1 A1C125 16A 1p + LSC L1 TMA. The assembly is intended for applications requiring a compact, manufacturer-specified outgoing protective device with a 16 A rated current and single-pole switching configuration.

The ABB Protecta Power selection information identifies the corresponding 16 A single-pole Formula A1 device with an 18 kA breaking capacity in its outgoing MCCB range. The EPX-A1B-016L1 is specifically configured for the L1 connection position, with related L2 and L3 variants available for other phase positions. This allows panel builders and electrical contractors to select the appropriate device configuration for the intended distribution assembly.

Key Advantages

  • Purpose-designed 16 A outgoing MCCB for compatible ABB Protecta Power panelboards.
  • Uses the established ABB Formula A1C125 circuit breaker platform.
  • Single-pole (1P) configuration for suitable phase conductor protection applications.
  • Thermal-magnetic protection against overload and short-circuit conditions.
  • 18 kA breaking capacity identified for the corresponding 16 A Formula A1 outgoing MCCB in ABB's Protecta Power selection information.
  • L1-specific connection arrangement for coordinated installation within the distribution assembly.
  • Includes the specified load-side connection (LSC) arrangement.
  • Provides a manufacturer-defined alternative to selecting an individual MCCB without the required panelboard connection components.
  • Suitable for commercial and industrial low-voltage distribution projects.
  • Part of ABB's coordinated Protecta Power outgoing circuit protection range.
  • Clearly identified by ABB order code 1SDA123176R1 for accurate specification and procurement.

Key Features

  • ABB Protecta Power Devices product family.
  • EPX-A1B-016L1 outgoing circuit breaker assembly.
  • 16 A rated current.
  • Single-pole (1P) circuit breaker configuration.
  • ABB Formula A1C125 device platform.
  • 125 A frame family, with a 16 A rated protective device.
  • Thermal-magnetic (TMA) protection designation in the manufacturer product description.
  • Overload protection using a thermal operating principle.
  • Short-circuit protection using a magnetic operating principle.
  • 18 kA breaking capacity identified for the corresponding outgoing device in ABB's Protecta Power selection guide.
  • L1 connection position.
  • LSC load-side connection arrangement.
  • Designed for compatible Protecta Power outgoing distribution ways.
  • Associated with separately specified MCCB base plate and cover components.
  • ABB lists a maximum cable capacity of 50 mm² for its A1 single-pole outgoing device range, subject to the actual terminal arrangement.
  • Related L2 and L3 connection variants available.
  • Manufacturer model EPX-A1B-016L1 and order code 1SDA123176R1.

16A Thermal-Magnetic Protection with an L1 Load-Side Connection

The ABB Protecta Power system provides a modular platform for low-voltage electrical distribution, with outgoing MCCB arrangements designed for different circuit ratings and connection positions. The EPX-A1B-016L1 is a 16 A single-pole outgoing device based on the ABB Formula A1C125 platform. It is intended for circuits requiring appropriately specified overload and short-circuit protection within a compatible Protecta Power assembly.

A thermal-magnetic MCCB uses two operating principles to protect an electrical circuit. The thermal element responds to sustained overcurrent conditions associated with overloads, while the magnetic element responds to higher fault currents associated with short circuits. The EPX-A1B-016L1 carries ABB's TMA designation. Exact trip characteristics and any adjustment provisions must be confirmed from the applicable device documentation rather than inferred from the designation alone.

ABB identifies the corresponding 16 A single-pole Formula A1 outgoing MCCB as an 18 kA device in its Protecta Power selection information. Breaking capacity must always be considered together with the relevant operating voltage, prospective short-circuit current and the complete installation's protection requirements. The selected circuit breaker must have suitable ratings for the actual electrical system and must be coordinated with upstream and downstream protective devices where required.

The L1 designation identifies the connection position for this particular Protecta Power outgoing assembly. ABB also lists the EPX-A1B-016L2 and EPX-A1B-016L3 as corresponding 16 A single-pole variants for the L2 and L3 positions. These are distinct product references and should be selected according to the intended outgoing way and ABB's panelboard configuration instructions.

The manufacturer's product description also specifies LSC, indicating the associated load-side connection arrangement. The correct connection components are important because the installation must provide suitable electrical contact, conductor termination and mechanical integration with the distribution assembly. The EPX-A1B-016L1 should therefore be specified as a complete manufacturer-defined outgoing device arrangement rather than treated as an interchangeable standalone breaker.

Protecta Power Installation and Accessory Compatibility

ABB's Protecta Power selection information states that an MCCB base plate and cover are required with each outgoing device. These accessories provide the relevant mounting and front-cover arrangement for the distribution assembly. The appropriate base plate and cover must be selected separately where they are not included in the ordered configuration, with compatibility checked against the actual panelboard and outgoing circuit position.

For the A1 single-pole outgoing device range, ABB lists a maximum cable capacity of 50 mm². This value is a general selection-guide reference and should not be interpreted as confirmation that every conductor type or termination arrangement is suitable. Cable sizing must account for the device terminals, conductor material, installation conditions, current-carrying capacity and relevant wiring regulations.

The 16 A rating is the current rating of the protective device, while A1C125 identifies the wider circuit breaker platform. The 125 A frame designation does not mean that the EPX-A1B-016L1 provides 125 A circuit protection. The correct outgoing device must be selected according to the circuit design current, cable protection requirements, prospective fault current and any applicable coordination studies.

The EPX-A1B-016L1 forms part of a broader ABB Protecta Power single-pole outgoing MCCB range. Related options include the EPX-A1C-020L1, EPX-A1C-025L1, EPX-A1C-032L1 and other higher-current variants. These devices differ in current rating and, where specified by ABB, breaking capacity. They should not be substituted without confirming the electrical design and compatibility of the complete distribution assembly.

Typical Applications

  • ABB Protecta Power outgoing circuit protection installations.
  • 16 A single-pole MCCB arrangements in compatible distribution panelboards.
  • Commercial building low-voltage electrical distribution systems.
  • Industrial electrical distribution assemblies requiring suitably rated outgoing protection.
  • Single-phase outgoing circuits within appropriately designed three-phase distribution systems.
  • Electrical panelboards requiring an L1-position outgoing device.
  • Circuits requiring thermal-magnetic overload and short-circuit protection.
  • Electrical switchrooms and building services distribution installations.
  • Switchboard manufacturing and electrical panel-building projects.
  • Compatible Protecta Power panelboard extensions and circuit additions.
  • Replacement of an appropriately matched ABB Protecta Power outgoing protective device.

Technical Specifications

Product group Protecta Power Devices
Series Protecta Power
ABB order code 1SDA123176R1
Manufacturer product description EPX-A1B-016L1 A1C125 16A 1p + LSC L1 TMA
Product type Outgoing moulded case circuit breaker assembly
Product category Low-voltage circuit protection devices
Device family ABB Formula A1
Device platform A1C125
Frame size 125 A
Rated current 16 A
Number of poles 1
Pole configuration 1P
Breaking capacity identified in ABB Protecta Power selection information 18 kA
Protection technology Thermal-magnetic
Manufacturer trip designation TMA
Protection functions Overload and short-circuit protection
Connection position L1
Connection arrangement LSC (load-side connection)
Installation position Outgoing circuit
Compatible product family ABB Protecta Power
Maximum cable capacity listed for A1 single-pole outgoing devices 50 mm², subject to terminal configuration
Associated installation accessories Compatible MCCB base plate and cover
Related L2 variant EPX-A1B-016L2
Related L3 variant EPX-A1B-016L3
Electrical system Low-voltage electrical distribution
Primary function Outgoing circuit overload and short-circuit protection

Frequently Asked Questions

What is the ABB EPX-A1B-016L1 used for?

The ABB EPX-A1B-016L1 is a 16 A single-pole outgoing MCCB assembly designed for compatible ABB Protecta Power electrical distribution panelboards. It provides thermal-magnetic overload and short-circuit protection and is configured for the L1 connection position.

What is the breaking capacity of the ABB EPX-A1B-016L1?

ABB's Protecta Power selection information identifies the corresponding 16 A single-pole Formula A1 outgoing MCCB with an 18 kA breaking capacity. The applicable voltage, device rating and installation fault level must be verified before specification.

What do L1 and LSC mean in the EPX-A1B-016L1 description?

L1 identifies the specified connection position for this outgoing device arrangement. LSC refers to the associated load-side connection. ABB also offers the EPX-A1B-016L2 and EPX-A1B-016L3 for corresponding L2 and L3 connection positions.

Does the ABB EPX-A1B-016L1 require additional installation accessories?

ABB's Protecta Power selection information states that a compatible MCCB base plate and cover are required with each outgoing device. The correct accessories must be selected for the intended panelboard arrangement, and the complete installation must follow ABB's assembly instructions.

What is the ABB order code for the EPX-A1B-016L1?

The manufacturer order code is 1SDA123176R1, and the model reference is EPX-A1B-016L1. The official product description is EPX-A1B-016L1 A1C125 16A 1p + LSC L1 TMA, within the ABB Protecta Power Devices product group.

Trusted ABB Protecta Power Circuit Protection Solutions

ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage protective devices, panelboards and installation accessories. The EPX-A1B-016L1 combines a 16 A single-pole Formula A1C125 thermal-magnetic circuit breaker with an L1-specific load-side connection arrangement to support outgoing circuit protection within compatible Protecta Power electrical distribution assemblies.