Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB EPX-A1B-016L1 Protecta Power 16 A single-pole Formula A1C125 thermal-magnetic outgoing MCCB assembly, order code 1SDA123176R1, with an L1-position load-side connection arrangement for compatible ABB Protecta Power electrical distribution panelboards.
£194.77
The ABB EPX-A1B-016L1 is a 16 A single-pole moulded case circuit breaker (MCCB) assembly designed for outgoing circuit protection within compatible ABB Protecta Power electrical distribution panelboards. Based on the ABB Formula A1C125 circuit breaker platform, this product combines thermal-magnetic protection with an L1-position load-side connection (LSC) arrangement for integration into the Protecta Power distribution system.
Part of the ABB Protecta Power Devices product group, the EPX-A1B-016L1 is identified by ABB order code 1SDA123176R1. Its manufacturer product description is EPX-A1B-016L1 A1C125 16A 1p + LSC L1 TMA. The assembly is intended for applications requiring a compact, manufacturer-specified outgoing protective device with a 16 A rated current and single-pole switching configuration.
The ABB Protecta Power selection information identifies the corresponding 16 A single-pole Formula A1 device with an 18 kA breaking capacity in its outgoing MCCB range. The EPX-A1B-016L1 is specifically configured for the L1 connection position, with related L2 and L3 variants available for other phase positions. This allows panel builders and electrical contractors to select the appropriate device configuration for the intended distribution assembly.
The ABB Protecta Power system provides a modular platform for low-voltage electrical distribution, with outgoing MCCB arrangements designed for different circuit ratings and connection positions. The EPX-A1B-016L1 is a 16 A single-pole outgoing device based on the ABB Formula A1C125 platform. It is intended for circuits requiring appropriately specified overload and short-circuit protection within a compatible Protecta Power assembly.
A thermal-magnetic MCCB uses two operating principles to protect an electrical circuit. The thermal element responds to sustained overcurrent conditions associated with overloads, while the magnetic element responds to higher fault currents associated with short circuits. The EPX-A1B-016L1 carries ABB's TMA designation. Exact trip characteristics and any adjustment provisions must be confirmed from the applicable device documentation rather than inferred from the designation alone.
ABB identifies the corresponding 16 A single-pole Formula A1 outgoing MCCB as an 18 kA device in its Protecta Power selection information. Breaking capacity must always be considered together with the relevant operating voltage, prospective short-circuit current and the complete installation's protection requirements. The selected circuit breaker must have suitable ratings for the actual electrical system and must be coordinated with upstream and downstream protective devices where required.
The L1 designation identifies the connection position for this particular Protecta Power outgoing assembly. ABB also lists the EPX-A1B-016L2 and EPX-A1B-016L3 as corresponding 16 A single-pole variants for the L2 and L3 positions. These are distinct product references and should be selected according to the intended outgoing way and ABB's panelboard configuration instructions.
The manufacturer's product description also specifies LSC, indicating the associated load-side connection arrangement. The correct connection components are important because the installation must provide suitable electrical contact, conductor termination and mechanical integration with the distribution assembly. The EPX-A1B-016L1 should therefore be specified as a complete manufacturer-defined outgoing device arrangement rather than treated as an interchangeable standalone breaker.
ABB's Protecta Power selection information states that an MCCB base plate and cover are required with each outgoing device. These accessories provide the relevant mounting and front-cover arrangement for the distribution assembly. The appropriate base plate and cover must be selected separately where they are not included in the ordered configuration, with compatibility checked against the actual panelboard and outgoing circuit position.
For the A1 single-pole outgoing device range, ABB lists a maximum cable capacity of 50 mm². This value is a general selection-guide reference and should not be interpreted as confirmation that every conductor type or termination arrangement is suitable. Cable sizing must account for the device terminals, conductor material, installation conditions, current-carrying capacity and relevant wiring regulations.
The 16 A rating is the current rating of the protective device, while A1C125 identifies the wider circuit breaker platform. The 125 A frame designation does not mean that the EPX-A1B-016L1 provides 125 A circuit protection. The correct outgoing device must be selected according to the circuit design current, cable protection requirements, prospective fault current and any applicable coordination studies.
The EPX-A1B-016L1 forms part of a broader ABB Protecta Power single-pole outgoing MCCB range. Related options include the EPX-A1C-020L1, EPX-A1C-025L1, EPX-A1C-032L1 and other higher-current variants. These devices differ in current rating and, where specified by ABB, breaking capacity. They should not be substituted without confirming the electrical design and compatibility of the complete distribution assembly.
| Product group | Protecta Power Devices |
|---|---|
| Series | Protecta Power |
| ABB order code | 1SDA123176R1 |
| Manufacturer product description | EPX-A1B-016L1 A1C125 16A 1p + LSC L1 TMA |
| Product type | Outgoing moulded case circuit breaker assembly |
| Product category | Low-voltage circuit protection devices |
| Device family | ABB Formula A1 |
| Device platform | A1C125 |
| Frame size | 125 A |
| Rated current | 16 A |
| Number of poles | 1 |
| Pole configuration | 1P |
| Breaking capacity identified in ABB Protecta Power selection information | 18 kA |
| Protection technology | Thermal-magnetic |
| Manufacturer trip designation | TMA |
| Protection functions | Overload and short-circuit protection |
| Connection position | L1 |
| Connection arrangement | LSC (load-side connection) |
| Installation position | Outgoing circuit |
| Compatible product family | ABB Protecta Power |
| Maximum cable capacity listed for A1 single-pole outgoing devices | 50 mm², subject to terminal configuration |
| Associated installation accessories | Compatible MCCB base plate and cover |
| Related L2 variant | EPX-A1B-016L2 |
| Related L3 variant | EPX-A1B-016L3 |
| Electrical system | Low-voltage electrical distribution |
| Primary function | Outgoing circuit overload and short-circuit protection |
The ABB EPX-A1B-016L1 is a 16 A single-pole outgoing MCCB assembly designed for compatible ABB Protecta Power electrical distribution panelboards. It provides thermal-magnetic overload and short-circuit protection and is configured for the L1 connection position.
ABB's Protecta Power selection information identifies the corresponding 16 A single-pole Formula A1 outgoing MCCB with an 18 kA breaking capacity. The applicable voltage, device rating and installation fault level must be verified before specification.
L1 identifies the specified connection position for this outgoing device arrangement. LSC refers to the associated load-side connection. ABB also offers the EPX-A1B-016L2 and EPX-A1B-016L3 for corresponding L2 and L3 connection positions.
ABB's Protecta Power selection information states that a compatible MCCB base plate and cover are required with each outgoing device. The correct accessories must be selected for the intended panelboard arrangement, and the complete installation must follow ABB's assembly instructions.
The manufacturer order code is 1SDA123176R1, and the model reference is EPX-A1B-016L1. The official product description is EPX-A1B-016L1 A1C125 16A 1p + LSC L1 TMA, within the ABB Protecta Power Devices product group.
ABB Protecta Power provides electrical contractors, panel builders and distribution system designers with a coordinated range of low-voltage protective devices, panelboards and installation accessories. The EPX-A1B-016L1 combines a 16 A single-pole Formula A1C125 thermal-magnetic circuit breaker with an L1-specific load-side connection arrangement to support outgoing circuit protection within compatible Protecta Power electrical distribution assemblies.